CLEAN WATER STORE 7500-REV2.5 Greensand Iron Filter Installation Guide
- June 13, 2024
- CLEAN WATER STORE
Table of Contents
- CLEAN WATER STORE 7500-REV2.5 Greensand Iron Filter
- Packing Lists
- Pre-Installation
- Installation of Your System in Copper or Metal Piping Systems
- How Your Greensand Filter Works
- Diagram of Typical Installation Well Water
- Filter Tank Assembly and Installation Instructions
- Pot Perm Tank Set Up
- Programming Your Valve and Setting Time and Days for Backwash
- Start the First Backwash
- Advanced Programming Mode
- Exploded Parts View
- 7500-Rev2.5 Water Filters Limited Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CLEAN WATER STORE 7500-REV2.5 Greensand Iron Filter
Thank you for purchasing a Clean Water System!
With proper installation and a little routine maintenance your system will
be providing iron free water for many years.
Please review this start-up guide entirely before beginning to install your
system, and follow the steps outlined for best results.
Minimum pressure of 30 PSI recommended. Maximum pressure recommended 80 PSI.
For indoor installation only.
Protect from sunlight, rain, and freezing.
GREENSAND MEDIA CONTAINS DUST.
USE MASK TO AVOID BREATHING DUST.
No potassium permanganate granules included. Order separately.
Questions?
Call us toll-free: 1-888-600-5426 or
1-831-462-8500
Email us: support@cleanwaterstore.com
See more information on our website:
www.cleanwaterstore.com/resources
Packing Lists
All systems include:
7500-REV2.5 control valve, small tube of silicone grease, bypass valve, power
supply, funnel for adding media, top screen, start-up guide, and items
included in one of the following options:
Find Your Size System to See What is Included:
-
Greensand Filter 0.75 cubic foot size
8” x 44” filter tank with distributor tube
9 lbs. filter gravel
0.75 cubic foot of Greensand. -
Greensand Filter 1.0 cubic foot size
9” x 48” filter tank with distributor tube
12 lbs. filter gravel
1 cubic foot of Greensand -
Greensand Filter 1.5 cubic foot size
10” x 54” filter tank with distributor tube
16 lbs. Filter gravel
1.5 cubic foot of Greensand -
Greensand Filter 2.0 cubic foot size
12” x 52” filter tank with distributor tube
20 lbs. filter gravel
2.0 cubic foot of Greensand -
Greensand Filter 2.5 cubic foot size
13” x 54” filter tank with distributor tube
35 lbs. filter gravel
2.5 cubic foot of Greensand
What to Do if Your Tank is Not Level Out of the Box:
Your black filter tank base is not glued to the bottom of your tank.
Occasionally tank bases will become crooked during shipment. If you find that
that your tank does not sit level on the floor, you can easily adjust it by
holding the empty tank and knocking it on a concrete or solid floor once or
twice to level it.
Pre-Installation
- Review your packing list and make sure you have received all the parts before installation.
- If you are going to be turning off the water to the house and you have an electric water heater, shut off the power to the water heater before beginning installation in case water heater is accidentally drained.
- Pick a suitable location for your filter system on a dry level spot where it won’t be exposed to freezing temperatures. A minimum of 20 PSI is required. Maximum pressure is 90 PSI.
- Get all of your plumbing parts together before beginning installation, and make sure you have received all of your packages before beginning or scheduling an installation. Installation typically takes 3 to 5 hours. However, after installation the Greensand Filter must be allowed to run through a complete regeneration (backwash and rinse cycle) with potassium permanganate.
- After the system is installed and running, your water may be discolored particularly if you have older or corroded piping. This typically clears up over a day or two.
Best Practices for Piping & Drain Installation
- Make sure to connect the Inlet from your water source and outlet, following arrows on control valve. Connect the External Flow Control fitting onto the Drain line.
- Make sure there is a working gate or ball valve before the system and also one after as well as a bypass valve.
- A hose bib (which is a faucet to which you can attach a garden hose) is strongly recommended after the Greensand Filter and before the second ball valve. This makes it easy to rinse your new Greensand Filter on start-up and gives you a place to test the water.
- If you will be using copper piping, do not sweat the copper pipe directly on to the 7500-REV2.5 control valve.
- To connect drain line to drain, use an air-gap connection, so that if your sewer or septic tank backs up, it cannot cross connect with the drain tubing.
- The pipe connectors are 1’ male pipe thread but you can add a reducer to reduce to ¾” pipe with common pipe fittings if needed.
- Make sure bypass valves are closed (system is in bypass) when you first start installing and keep on bypass until you are ready to start it up with the first backwash.
How the Bypass Valve Works
Turn knob so the valve is bypassed when installing.
When you go to start up system turn the bypass SLOWLY to let water in and put
in service.
Installation of Your System in Copper or Metal Piping Systems
- If your new filter system is to be installed in a metal (conductive) plumbing system, i.e., copper, or galvanized steel pipe, the plastic components of the system will interrupt the electrical continuity of the plumbing system.
- As a result, any stray currents from improperly grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through the contiguous metal plumbing.
- Some homes may have been built in accordance with building codes, which encouraged the grounding of electrical appliances through the plumbing system.
- Consequently, the installation of a bypass consisting of the same material as the existing plumbing, or a grounded “jumper wire” bridging the equipment and reestablishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use.
- This is simple and easy step to take if you are installing your water treatment system into copper piping.
- A simple ground jumper wire with a pipe clamp can be purchased at any Home Center, or hardware store etc. for a few dollars.
How Your Greensand Filter Works
Water enters the top of the tank and flows down through the media and up the
distributor tube. Iron and manganese are removed and trapped in the greensand
media.
During backwash the flow of water is reversed and water flows down the
distributor tube and up through the media, lifting and expanding the Greensand
media and washing out the trapped iron and manganese to drain.
After the first backwash, a brine draw cycle draws in potassium permanganate
solution from the pot perm tank and slowly rinses and restores the greensand
media in a process called “regeneration”.
The 7500-Rev4 Control Valve tracks the amount of water that is used and will
backwashbased on gallons OR every 4 to 7 days, whichever comes first.
The number of gallons and days between backwashes can be adjusted to suit your
needs.
Diagram of Typical Installation Well Water
Filter Tank Assembly and Installation Instructions
- Wrap the top of distributor tube with electrical or duct tape so that no gravel or Greensand media will go down the distributor tube when adding the media.
- Add the filter gravel that came with your order. You want the gravel to cover the bottom distributor screen before adding the Greensand media.
- Next add Greensand media. The tank should be about 2/3rds full of media, do not fill more than 2/3rds, even if there is some media left over.
- Remove cap or tape from top of distributor tube. Be careful not to pull up distributor tube.
- A 1 cup of Clorox or other chlorine bleach and fill tank completely with water. This will allow the Greensand Backwash Filter media to settle and reduce the need of purging the air out of the tank later. Allow Greensand to soak for at least 1 hour but 24 hours or more is OK.
- Add a small amount of silicone grease to the inner O-ring, where the distribution tube goes.
- Next, install the top screen by inserting upwards and rotating to lock in place. (This is a funnel- shaped plastic screen that locks into the bottom side of control valve.
- Lubricate the main tank O-ring with silicone grease and screw on the 7500-Rev2.5 control valve carefully. Do not use pipe-joint compound, vegetable oil, Teflon tape, or Vaseline or other greases to lubricate tank threads.
- Connect bypass assembly with 1” pipe connectors to control valve install black clips and make sure valve is in bypass position.
- Insert meter cable into meter cable port on bypass.
- Install inlet and outlet piping and hook up drain line tubing to drain.
- If you are in earthquake zone, strap your backwash filter tank to wall with metal strapping.
- Proceed to programming your 7500-Rev2.5 control valve timer and backwash frequency.
- IMPORTANT: you must program the time and then start a backwash and rinse. The filter system must be backwashed and rinsed several times before using. See following pages for instructions.
Pot Perm Tank Set Up
- First remove the rubber band in the pot perm tank, that comes on the float assembly from the manufacturer.
- Add enough clean water to the pot perm solution tank to bring water level about 1” above the felt pad.
- Add one 2-lb or one 5-lb jug of potassium permanganate granules to the potassium perm tank by pouring it directly on top of the white felt pad.
- Do not pour permanganate down the white plastic brine well where the black line is attached.
- See the over-flow barbed fitting for the safety float on the side of the perm tank.
- You do not have to connect this to a drain. But, if the safety float were to malfunction, there is a small chance that pot perm solution will leak or drip out of this fitting.
- If this would cause a big mess where you have installed the greensand filter, hook some tubing to this and run to a bucket, floor pan or floor drain. Normally no pot perm solution will leak out of this fitting.
Programming Your Valve and Setting Time and Days for Backwash
Backwash: Press the Back / Regen button
Pressing “Back Regen” at any time results in an immediate manual regeneration.
Pressing and holding for 3 seconds, when system is locked, results in a delayed regeneration at the preselected time.
Extended Power Outage Indicator
If power outage exceeds 3 days, the time-of-day indicator “_” will flash
12:12. The current time of day needs to be re-set. All other set parameters
remain stored in memory. The valve will resume to operate from the point of
the power outage.
Lockout Function
Keypad will lock after 5 minutes without use. To access the parameter changes,
press and hold “Up” and “Down” buttons simultaneously for 3 seconds to unlock.
Set Time of Day
- If LOCK icon is lit, press, and hold both UP and DOWN buttons for 3 seconds to unlock keypad.
- Then press the MENU/CONFIRM button to enter the main menu.
- Press DOWN button to select “Set Time of Day”
- Press the MENU/CONFIRM button again to change time of day (Hour will flash)
- Adjust hour by using DOWN or UP buttons.
- Press the MENU/CONFIRM button again to change minutes (Minutes will flash)
- Adjust minutes by using DOWN or UP buttons.
- Press Back/Regen
Set Date
- If LOCK icon is lit, press, and hold both UP and DOWN buttons for 3 seconds to unlock keypad.
- Then press the MENU/CONFIRM button to enter the main menu.
- Press DOWN button to select “Set Date”
- Month: Press the MENU/CONFIRM button again to change time of day (Month will flash) and adjust to current Month date by using DOWN or UP buttons.
- Day: Press the MENU/CONFIRM button again to change Day date (Day date will flash) and adjust to current day date by using DOWN or UP buttons.
- Year: Press the MENU/CONFIRM button again to change Year date (Year date will flash) and adjust to current Year by using DOWN or UP buttons.
- Press BACK/REGEN button to save current date and go back to menu.
- Continue to review and/or change the remaining settings (as follows)
Set Capacity
This refers to the number of gallons your 7500-Rev2.5 is set to backwash.
Default is 800 Gallons. This means that your filter will backwash every 1400
gallons of water used, OR every 4 days, whichever comes first, since your
Maximum Days for Regen. Is set to every 4 days as well.
- Set Regen Time This is the time your system will backwash. Default is 2:00 AM
- Set Backwash Time Length Set for 10 minutes. This is the first cycle.
- Set B. S. R. Time “Brine Slow Rinse” time. Set for 60 minutes. This is where the potassium permanganate solution is drawn in to the system.
- Set Secondary Backwash Time Set for 8 minutes.
- Set Fast Rinse Time Set for 8 minutes.
- Set B. R. Time ”Brine Refill” – this is where the pot perm tank refills. Pick your iron filter size and enter minutes.
- Maximum Days for Regen. Set to 4 Days. This refers to the days between each backwash. The recommended initial setting for the Greensand Filter is every 4 days for families or heavy use and every 7 days for 1 to 2 persons in the home.
B.R. Times
0.75 CF| 4 MIN.
1.0 CF| 5 MIN.
1.5 CF| 6 MIN.
2.0 CF| 7 MIN.
2.5 CF| 8 MIN.
Usage Logs: The following are diagnostic menus you can review later if
you wish:
Daily Usage Log
Daily Peak Usage
Weekly Usage Log
Weekly Peak Usage
Monthly Usage Log
Monthly Peak Usage
Review Regen. Times
Start the First Backwash
- After programming, the system must be run through 2 or 3 backwash/rinse regeneration cycles to clean the new filter media.
- Start with both bypass valves in the Bypass Position.
- Press the BACK/REGEN button once to enter the backwashing cycle.
- When the backwash icon is displayed, slowly open the bypass to a quarter position to make the water flow into the tank and out the backwash drain line to drain.
- After several minutes open bypass valve completely.
Backwash Flow
Rates
0.75 CF| 5 GPM
1.0 CF| 5 GPM
1.5 CF| 5 GPM
2.0 CF| 7 GPM
2.5 CF| 10 GPM
6. If possible, verify that the backwash flow corresponds with the size of your system below. Run drain hose to a bucket & verify the flow rate in gallons per minute. An adequate backwash is critical. For example, if the backwash water fills a 5-gal bucket in 1 minute, you have 5 gallons per minute (GPM).
7. After the backwash, the system will automatically go into the fast rinse stage. The control valve will return to service status (indicated by the up flowing meter on the left).
8. Repeat the Regeneration (backwash and rapid rinse cycle) step one or two more times.
Congratulations, you are done setting up your valve!
Pink Water After the Greensand Filter
Note if you see pink water in the house after the greensand, this means that a
cycle has been interrupted. This is caused when potassium permanganate
solution is drawn into the greensand filter but then the backwash or rinses
are interrupted.
This can happen is there is a power interruption during the regeneration
(backwash, rinse) process. If you see pink water, run the water in the house
until the water is clear.
Put the system on bypass or allow to run through a complete regeneration if
you see pink water.
Advanced Programming Mode
The Advanced Programming Mode allows you to set the Regen Cycle and Regen Mode. Skip this for most applications as your filter system has already been set to correct modes.
- Plug the RevV4 in and immediately press in sequence MENU/CONFIRM, then press BACK/REGEN button, then press the DOWN button to enter the Advanced Programming Mode.
- Press UP or DOWN buttons or to select the menu item to be changed
- Note: If valve locks while programming, unplug power supply and repeat step above.
- Press MENU/CONFIRM to enter the main menu
- Press the UP or DOWN buttons to highlight each option.
- Press MENU/CONFIRM to enter highlighted option.
- Press the UP or DOWN buttons to adjust the value.
- Press the MENU/CONFIRM to accept the changes.
- Press BACK/REGEN button to advance to service status
Screen View | Default Settings |
---|---|
Review Company Info | CWS 831‐462‐8500 |
Set Valve Model | 62605 |
Set Language | English |
Set Company Info | CWS 831‐462‐8500 |
Set Hour Mode | 12 HR |
Set Time of Day | Current time of day |
Set Date | Current date |
Set Program Type | Interlock |
Set Regen Cycles | No. 2 |
Set Set Clear Data | Close |
Set Regen Mode | A-01 |
Set Capacity | 800 |
Set Regen Time | 2:00 AM |
Set Backwash Time | 10 Minutes |
Set B.S.R. Time | 60 Minutes |
Set Secondary B.W.T. | 8 Minutes |
Set Fast Rinse Time | 8 Minutes |
Set B.R. Time | 10 Minutes |
Max Days for Regeneration | 4 |
Signal Output Mode | b‐01 |
Set Service Alarm | Disabled |
Review Regen Times | NA |
Review Software Version | Ver. 5.0 |
When to Add More Potassium Permanganate
Add one 5-lb jug of potassium permanganate every 3 – 4 months. Check the
potassium permanganate solution tank and when you see the mound of potassium
permanganate disappear after a few months, just add another 5-lb jug. In some
cases, you won’t see the mound; you might just see solution after a couple of
weeks. If you have it set to regenerate (backwash cycles) every 1 – 3 days,
you might need to add it more frequently, perhaps every 2 months.
Clean the Injector
Once a year clean the nozzle and throat on the injector. Turn off water
pressure to your system and release any pressure by opening a hose bib or
faucet downstream of the filter system. Remove the two bolts covering the
injector on the side the Rev4 Control Valve, near where the 3/8” tube from the
pot perm tank attaches to the control valve.
Using small screwdriver remove the injector nozzle and throat and filter screen and clean with paperclip and rinse in vinegar to remove any deposits
Exploded Parts View
7500-Rev2.5 Water Filters Limited Warranty
We warrant this water filter when installed according to factory recommendations, to be free from defects in materials and workmanship as follows:
Limited Warranty
This water conditioner unit is comprised of the finest industry components
available. Each individual component used in the assembly of our equipment is
covered by the original equipment manufacturer’s warranty. All components,
except those specifically listed below, are warranted for a period of one (1)
year from date of installation to the original purchaser to be free of defects
in materials and workmanship subject to the manufacturer’s conditions and/or
the conditions shown below.
Mineral Tanks
The fiberglass, polyglass or composite mineral tanks used in the assembly of
this unit are warranted to be free of defects in materials and workmanship for
a period of ten (10) years on 6” – 13” size tanks, and five (5) years on 14”
and larger size tanks used for softener/filtration applications, subject to
the manufacture’s conditions and/or the conditions shown below. Warranty does
not cover exposure to weather, freezing, fractures caused by external impact,
or exposure to vacuum.
Control Valves
The CWS control valve is warranted to be free of defects in materials and
workmanship for a period or five (5) years.
Conditions
- This warranty only covers water conditioners installed for residential use. Water conditioners installed for commercial or industrial applications are guaranteed for one (1) year from the date of installation.
- Installation must be made in accordance with legal or local codes and manufacturer’s recommendations.
- Failure must not result from exposure to weather, rodents, misuse, alteration, fire, lightning, power surges or neglect.
- Water pressure must not exceed 100 PSI and water temperature must not exceed 100 degrees.
- Subject to the above terms and conditions we will replace and/or repair, at our option, any parts of the water conditioner found defective in materials and workmanship. Defective parts must be returned, freight pre-paid for repair or replacement.
- This warranty does not cover labor, shipping charges, damages caused by delays of consequential damages or other causes beyond our control. Warranty does not cover pipes, fixtures or appliances. Warranty extends to the actual water conditioner components only.
- This warranty is to the original purchaser and is not transferable to any subsequent owner(s).
- No other guarantees or warranty, expressed or implied, is applicable to our product. No repair or replacement made under the terms of the warranty shall extend this warranty.
- Any product returned to Clean Water Store without a valid return authorization number will be rejected. Any product found to be defective will, at the sole discretion of Clean Water Store be repaired or replaced. Clean Water Store is not responsible for shipping cost to the repair facility.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>