Oase AquaAir Eco 250 Floating Aerator Instruction Manual
- June 13, 2024
- Oase
Table of Contents
Oase AquaAir Eco 250 Floating Aerator
Product Information
Product Name | AquaAir Eco 250 |
---|---|
Manufacturer | Water Gardening Direct |
Model Number | AAR0010 |
Product Usage Instructions
Installation and Connection
Assembling the unit:
- Refer to the included fastening material for proper assembly.
Adjusting the injector nozzle:
- To optimize the effect of the injector nozzle, ensure that it is directed downwards towards the bottom of the pond.
- Note the specified minimum distances from the bottom of the pond.
- Loosen the knurled screw to adjust the position of the injector nozzle.
Electrical Connection
WARNING: Disconnect all electrical units in the water from the power supply before proceeding. It is recommended to hire a qualified electrician to perform the electrical installation.
-
The electrician will be able to detect potential risks and
adhere to regional and national standards, regulations, and directives. -
The electrical installation should be performed by a qualified electrician experienced in outdoor areas.
-
The installation should include a fault current protection device with a maximum fault current of 30 mA.
-
Ensure that the electrical connection is splash-proof.
Safe Operation
Read and follow all safety information provided in the user manual.
Intended Use
The AquaAir Eco 250 is designed for use in water gardening applications.
Product Description
The AquaAir Eco 250 features the following components:
- Float
- Drum with integrated pump
- Power connection cable
- OASE Control OUT
- OASE Control IN
- Injector nozzle with Venturi principle
- Hose for air intake
- Knurled screw (used to adjust the injector nozzle)
- Fastening material (included in the scope of delivery)
The AquaAir Eco 250 can be controlled via the OASE control network. It can be connected to either the OASE Garden Controller or the OASE InScenio FM-Master Home/Cloud. For more information on OASE Control, visit www.oase.com.
Safety information
Electrical connection
- Special regulations apply to electrical installation in outdoor Only allow a qualified elec- trician to perform the electrical installation.
- The qualified electrician has the required professional training, knowledge and skills to per- form electrical installations in outdoor areas. The qualified electrician can detect potential risks and adheres to regional and national standards, regulations and directives.
- For your own safety, please consult a qualified electrician.
- Only connect the unit if the electrical data of the unit and the power supply
- Only plug the unit into a correctly installed Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
- Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
- Protect open plugs and sockets from
Safe operation
- Do not use the unit, if electrical lines or the housing are
- A damaged connection cable cannot be Dispose of the unit.
- Do not carry or pull the unit by its power
- Never make technical modifications to the unit.
- Only carry out work on the unit that is described in this manual
- Only use original spare parts and accessories.
- Route lines so that they are protected from damage and nobody can trip over
- Should problems occur, please contact the authorized customer service or
Intended use
Only use the product described in this manual as follows:
- For aerating bodies of water
- In compliance with the technical specifications.
The following restrictions apply to the unit:
- Do not use in accessible water
- Never use the unit with fluids other than water.
- Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive
- Never run the unit without water.
- Do not use for commercial or industrial
Product Description
Overview
A:
Installation and connection
Assembling the unit
B:
- Screw the injector nozzle onto the pump outlet.
- Attach the hose ends to the connection sockets on the injector nozzle and on the float
- Fasten the hose with the hose clips
Adjusting the injector nozzle
C:
-
Undo the knurled screw for locking the drum.
-
Turn the drum until the injector nozzle is in the desired position.
-
Tighten the knurled screw.
To optimize the effect of the injector nozzle, note the specified minimum distances from the bottom of the pond.- When the injector nozzle is directed downwards towards to the bottom of the pond, it generates deep aeration, thereby biologically activating the pond
- When the injector nozzle is directed at a flatter angle, it generates a stronger water
Connecting the control system
D:
Connect the AquaAir Eco 250 to the OASE Garden Controller or the OASE InScenio
FM-Master Home/Cloud and control the AquaAir Eco 250 using OASE Control
.
-
For information on OASE Control visit www.oase.com.
Integrate the AquaAir Eco 250 in the OASE Control network either as the only or as the final station.- The line length in the OASE Control network is limited. If the network cable is looped through (IN/OUT) on the AquaAir Eco 250 the network cable can reach a length of 197 ft due to the 98 ft network connection cable.
Connecting and disconnecting the OASE Control plug connection
E:
NOTE : The unit will be destroyed if water penetrates the plug connector.
- Connect the plug connector or place the protective cap on the plug connector.
- Ensure that the rubber seal is clean and fits precisely. If the rubber seal is damaged, replace it.
- Secure the plug connector or protective cap with the two screws.
Installing the unit
F:
WARNING : Severe injuries or death from the operation of the unit in a
swimming pond. Faulty electric components will apply dangerous electric
voltage to the water.
- Never operate the unit in a swimming pond.
Ensure that the connection to the power supply is at least 6.5 ft from the edge of the pond.
Fastening the unit on the side of the pond
G:
- Shorten two-wire cables to the desired length.
- Form loops at each of the cable ends and fasten these with cable clamps.
- Anchor the aerator using the two wire cables, the safety hook, and the two pegs driven in at the side of the pond.
- Adhere to the specified anchoring angles so that the aerator cannot move.
- Relieve strain from the power cable and protect the power plug from wetness.
Fastening the unit to the bottom of the pond
H:
- Shorten two-wire cables to the desired length (minimum 16.5 ft).
- Form loops at each of the cable ends and fasten these with cable clamps.
- For anchoring to the bottom of the pond, screw the two threaded hooks into, for instance, two sufficiently heavy stones using dowels.
- Attach the cables to the threaded hooks using the safety hooks and lower the stones to the bottom of the pond.
- Adhere to the specified anchoring angles so that the aerator cannot move.
- Anchor the aerator using the two wire cables and the safety hook.
- Relieve strain from the power cable and protect the power plug from wetness.
Commissioning/start-up
NOTE: The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
- Do not connect the unit to a dimmable power supply.
NOTE : Never allow the pump to run dry. Otherwise the pump will be destroyed.
- Only operate the pump while it is submerged.
Switching ON/OFF
- Switching on: Plug the power plug into the outlet.
- The unit switches on immediately.
- Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test
(Environmental Function Control (EFC)). The pump detects if it is running dry
/ blocked or submerged. The pump switches off automatically after approx. 90
seconds if it runs dry/is blocked. In the event of a malfunction, disconnect
the power supply and “flood the pump” or remove the obstacle. Afterward, the
unit can be restarted.
Original operating manual. This operating manual belongs with the unit and must always be handed over together with the unit.
WARNING
- Disconnect all electrical units in the water from the power supply before reaching into the water. Otherwise, there is a risk of injuries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision
A more detailed operating manual is available for download as a PDF online: www.oase.com/manual
The following additional topics are addressed in the operating manual:
- Product features, symbols on the unit
- Cleaning and maintenance, storage/winter-proofing, malfunction repair
- Technical data, wear parts, spare parts, disposal
OASE GmbH Tecklenburger Straße 161 48477 Hörstel, Germany +49 (0) 5454 80-0 +49 (0) 5454 80-9353 info@oase.com
References
- OASE Consumer
- OASE Consumer
- Manuals A-Z - OASE
- Pond Equipment and Pond Filtration Equipment - Water Gardening Direct
- Manuals A-Z - OASE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>