SmartVent Evolve2 Home Ventilation Systems Instruction Manual
- June 13, 2024
- Smartvent
Table of Contents
HOME VENTILATION SYSTEMS
HOME VENTILATION SYSTEMS
SmartVent provides reliable home ventilation to NZ, catering for homeowners
and builders that value affordability, efficiency and comfort.
Our intuitive systems are powered by progressive technology to maintain
optimal air quality, providing an extra layer of protection against
respiratory health threats and keeping the temperature just right all year
round.
We’re able to tailor our domestic ventilation services to suit any property,
also specialising in POSITIVE PRESSURE SYSTEMS & HEAT & ENERGY RECOVERY
SYSTEMS
enquiry@smartvent.co.nz |
www.smartvent.co.nz
Visit our website for more information https://www.smartvent.co.nz
SmartVent is a Simx owned brand.
Overview
SmartVent Evolve2 is a centralised positive pressure system that constantly
evaluates the environmental dynamics in and around your home. Four temperature
and humidity sensors measure moisture content throughout the home, in the roof
cavity and outside,
to calculate dew point which is the measure of when condensation will appear
on the windows given the internal temperature and moisture conditions combined
with the temperature of the coldest surface. This comprehensive and clever
solution can then determine how much improved air quality to introduce to
effect change without the risk of over−ventilating. Market−leading Evolve2
technology comes with a range of fantastic features such as flexible upgrade
options with weekly scheduling, dew point control, all easily navigated with
the intuitive wall controller. Just set the preferred temperature and the
system does the rest.
Home Ventilation Systems
SmartVent Evolve2 Range
Home ventilation system suitable for most types of homes.
Model | Description | Product Code |
---|---|---|
SV02E2 | 2 room system (expandable to 3 max.) for homes up to 100m | FAN6910 |
SV04E2 | 4 room system (expandable to 6 max.) for homes up to 280m | FAN6911 |
SV06E2 | 6 room system (expandable to 10 max.) for homes up to 560m | FAN6912 |
System Extensions
3m Duct | 6m Duct | Through Wall |
---|---|---|
DCT2276 | DCT2667 | DCT2286 |
Extension kits can be used to add more outlets to your SmartVent home
ventilation system.
Features and Seasonal Add−Ons
Features
Dew Point Control|
---|---
Humidity Sensing|
Temperature Sensing|
Low Temperature Protection|
Auto or Manual Operation|
Boost Control|
Filter Change Alert|
Screen Brightness Control|
Scheduler|
Seasonal Add−Ons 1)
Summer Feature|
---|---
Heat Transfer|
Tempering Heater|
- See page 180 for full information on Seasonal Add−On options
Control Your Climate
Comprehensive humidity control protection against moisture, mould and mildew
with multiple seasonal add−on options
SV02E2
SV04E2
SV06E2
SmartVent Positive+ Range
Home ventilation system suitable for most types of homes.
Model| Description|
Order Code
---|---|---
SV01P+| 1 room system (expandable to 3 max.) for homes up to 100m2| FAN7280
SV02P+| 2 room system (expandable to 3 max.) for homes up to 100m2| FAN7281
SV04P+| 4 room system (expandable to 6 max.) for homes up to 280m2| FAN7282
SV06P+| 6 room system (expandable to 12 max.) for homes up to 560m2| FAN7283
System Extensions
3m Duct| 6m Duct|
Through Wall
---|---|---
DCT2276| DCT2667| DCT2286
Extension kits can be used to add more outlets to your SmartVent home
ventilation system.
Features and Seasonal Add−Ons
Humidity Sensing|
---|---
Temperature Sensing|
Low Temperature Protection|
Auto or Manual Operation|
Rental Property Lock|
Boost Control|
Filter Change Alert|
Screen Brightness Control|
Scheduler|
Seasonal Add−Ons 1)
Summer Feature|
---|---
Heat Transfer|
Tempering Heater|
Condensation Control Plus
Integral humidity guard against moisture, mould and mildew with multiple
seasonal add−on options
Model | Description | Product Code |
---|---|---|
SV01P2 | 1 system outlet (expandable to 3 max.) for homes up to 100m 2 | FAN2023 |
SV02P2 | 2 system outlets (expandable to 3 max.) for homes up to 100m 2 |
FAN0939
SV04P2| 4 system outlets (expandable to 6 max.) for homes up to 280m 2|
FAN1057
SV06P2| 6 system outlets (expandable to 12 max.) for homes up to 560m 2|
FAN1064
System Extensions
3m Duct | 6m Duct | Through Wall |
---|---|---|
DCT2276 | DCT2667 | DCT2286 |
Extension kits can be used to add more outlets to your SmartVent home
ventilation system.
Features and Seasonal Add−Ons
Temperature Sensing|
---|---
Low Temperature Protection|
Auto or Manual Operation|
Rental Property Lock|
Boost Control|
Filter Change Alert|
Screen Brightness Control|
Scheduler|
Seasonal Add−Ons1)
Summer Feature|
---|---
Heat Transfer|
Tempering Heater|
- See page 180 for full information on Seasonal Add−On options
Control Condensation
Reduce moisture, mould and mildew with multiple seasonal add−on options
SmartVent Lite+
Overview
SmartVent Lite+ is a home ventilation system that monitors both temperature
conditions and humidity to ensure that you are protecting your home or rental
property with quality air always circulating and keeping the property dry. As
a temperature and humidity based solution, in winter, SmartVent Lite+ not only
introduces air faster when warmer and slower when cooler, the system also
measures the moisture content in the home and of the incoming air and uses
this data to reduce under or over ventilation. The rental lock feature enables
a property owner to lock the controller to prevent tenants from switching the
system OFF while still allowing system temperatures, fan speeds and
ventilation scheduler adjustments to suit the lifestyles/needs of the
occupants. Low temperature protection, set at a user adjustable default
setting of 5°C, ensures that continuous cold air is not introduced when the
incoming air conditions are too cold.
SmartVent Lite+ Range
Home ventilation system suitable for most types of homes.
Model| Description|
Order Code
---|---|---
SV01L+| 1 room system (expandable to 3 max.) for homes up to 100m2| FAN7270
SV02L+| 2 room system (expandable to 3 max.) for homes up to 100m2| FAN7271
SV04L+| 4 room system (expandable to 6 max.) for homes up to 280m2| FAN7272
SV06L+| 6 room system (expandable to 12 max.) for homes up to 560m2| FAN7273
System Extensions
3m Duct
DCT4276
Extension kits can be used to add more outlets to your SmartVent home
ventilation system.
Features
Humidity Sensing|
---|---
Temperature Sensing|
Low Temperature Protection|
Auto or Manual Operation|
Rental Property Lock|
Boost Control|
Filter Change Alert|
Screen Brightness Control|
Scheduler|
Investment Protection Plus
Cost effective solution including an integral humidity guard against moisture,
mould and mildew
SmartVent Lite2
Overview
SmartVent Lite2 is an economical home ventilation system that monitors
temperature conditions to ensure that you are protecting your home or rental
property with quality air always circulating. As a standard temperature−based
solution, bringing air in faster when warmer and slower when cooler, SmartVent
Lite2 is commonly referred to as a “Landlord Solution” or a cost−effective
solution to protecting their property investment. The rental lock feature
enables a property owner to lock the controller to prevent tenants from
switching the system OFF while still allowing system temperatures, fan speeds
and ventilation scheduler adjustments to suit the lifestyles/needs of the
occupants. Low temperature protection, set at a user adjustable default
setting of 5°C, ensures that continuous cold air is not introduced when the
incoming air conditions are too cold.
SmartVent Lite2 Range
Home ventilation system suitable for most types of homes.
Model| Description|
Order Code
---|---|---
SV01L2| 1 room system (expandable to 3 max.) for homes up to 100m2| FAN6803
SV02L2| 2 room system (expandable to 3 max.) for homes up to 100m2| FAN6804
SV04L2| 4 room system (expandable to 6 max.) for homes up to 280m2| FAN6805
SV06L2| 6 room system (expandable to 12 max.) for homes up to 560m2| FAN6806
System Extensions
3m Duct
DCT4276
Extension kits can be used to add more outlets to your SmartVent home
ventilation system.
Features
Temperature Sensing|
---|---
Low Temperature Protection|
Auto or Manual Operation|
Rental Property Lock|
Boost Control|
Filter Change Alert|
Screen Brightness Control|
Scheduler|
Protect Your Investment
Cost effective solution to reduce moisture, mould and mildew
Positive Pressure Systems
Selection Guide
What is the size of your
home (m²)?| Range selection| How many rooms do you
wish to distribute to?| Model| Product Codes
---|---|---|---|---
Up to 100m²| SmartVent Evolve2
SmartVent Positive+
SmartVent Positive2| 1| SV01P+
SV01P2| FAN7280
FAN2023
2| SV02E2
SV02P+
SV02P2| FAN6910
FAN7281
FAN0939
3| Extension Kit| DCT2276
SmartVent Lite+
SmartVent Lite2| 1| SV01L+
SV01L2| FAN7270
FAN6803
2| SV02L+
SV02L2| FAN7271
FAN6804
3| Extension Kit| DCT4276
Up to 280m²| SmartVent Evolve2
SmartVent Positive+
SmartVent Positive2| 4| SV04E2
SV04P+
SV04P2| FAN6911
FAN7282
FAN1057
5 − 6| Extension Kit| DCT2276
SmartVent Lite+
SmartVent Lite2| 4| SV04L+
SV04L2| FAN7272
FAN6805
5 − 6| Extension Kit| DCT4276
Up to 560m²| SmartVent Evolve2
SmartVent Positive+
SmartVent Positive2| 6| SV06E2
SV06P+
SV06P2| FAN6912
FAN7283
FAN1064
7 − 12| Extension Kit| DCT2276
SmartVent Lite+
SmartVent Lite2| 6| SV06L+
SV06L2| FAN7273
FAN6806
7 − 12| Extension Kit| DCT4276
IMPORTANT
-
If you exceed the number of rooms listed in the selection guide above, the performance of the system will not work as designed.
Your system should be reviewed with SmartVent before purchase and installation. -
Maximum outlets are listed above, do not exceed the number listed.
-
For the SV06 systems do not exceed 3 additional extension kits per branch of the system.
- DCT1491 and DCT3418 consist of 2 x 1kW units for installation into each branch of an SV06P, SV06P2, SV06P+ or SV06E2 system.
**DCT4613 consists of 2 x 2 kW heaters for installation into each branch of an SV06P2, SV06P+ or SV06E2 system.
Add−On Kits| SV01P+ SV01P2 SV01P| SV01L+ SV01L2| SV02E2 SV02P+ SV02P2 SV02P|
SV02L+ SV02L2| SV04E2 SV04P+ SV04P2 SV04P| | SV04L+ SV04L2| SV06E2 SV06P+
SV06P2 SV06P| | SV06L+ SV06L2
---|---|---|---|---|---|---|---|---|---|---
3m Duct| DCT2276| DCT4276| DCT2276| DCT4276| DCT2276| | DCT4276| DCT2276| |
DCT4276
Additional Room| 6m Duct| DCT2667| −| DCT2667| −| DCT2667| | −| DCT2667| | −
Through Wall| DCT2286| −| DCT2286| −| DCT2286| | −| DCT2286| | −
Additional Fan| 150mm
200mm| FAN5836| −
−| FAN5836
FAN5837| −
−| FAN5836
FAN5837| | −
−
| FAN5836
FAN5837| | −
−
FAN5837
Outdoor Air Supply| SV01P2 SV01P| SV01L2| SV02E2 SV02P2 SV02P| SV02L2| −| | −|
−| | −
Controllers and Componentry
These recommendations are based on the standard components in the system.
− This selection guide assumes 2.4m stud height, if greater please increase
the square metre size by 4% for every 0.1 metre.
For example for a 2.8m stud height, increase your house size by 16%.
− If you choose to exceed the number of rooms listed in the selection guide
above, the performance of the system will be affected.
− By adding additional outlets to the system the available air is being
divided amongst more rooms.
− Extra duct may be required depending on the size and layout of the home (see
Accessories on page 196).
− For larger homes please contact SmartVent for technical advice on 0800 140
150.
Specifications
Fan Dimensions (mm) | A | B | C | D | E | F |
---|---|---|---|---|---|---|
Spigot Size − 150mm | 340 | 150 | 280 | 170 | 50 | 60 |
Spigot Size − 200mm | 340 | 200 | 280 | 170 | 50 | 60 |
Positive Pressure Systems Seasonal Upgrades
Summer Feature
Seasonal Add−On| SV01P+ SV01P2 SV01P| SV01L+ SV01L2| SV02E2 SV02P+ SV02P2|
SV02L+ SV02L2| SV04E2 SV04P+ SV04P2 SV04P| SV04L+ SV04L2| SV06E2 SV06P+ SV06P2
SV06P| SV06L+ SV06L2
---|---|---|---|---|---|---|---|---
Summer Feature| DCT2134| −| DCT2134| −| DCT2128| −| DCT2135| −
Home Ventilation Systems
The Summer Feature seasonal add−on is an optional second air intake located under the eaves or at the gable end of the home (weatherproof grille maybe required). This feature provides an alternative air supply for use during summer months.
- When installed on the south side of the house it ensures the coolest possible air is used.
- If the house design prevents the installation of a Summer Feature Seasonal Add−On, there are alternative options for a second air source such as through roof kits. SmartVent have a full range of accessories available to assist.
Outdoor Air Supply
Kit| SVO1 P2
SVO1P| SVO1 L2| SVO2E2
SVO2P2
SVO2P| SVO2L2| SVO4E2 SVO4P+ SVO4P2 SVO4P| SVO4L+
SVO4L2| SVO6E2 SVO6P+ SVO6P2 SVO6P| SVO6L+
SVO6L2
---|---|---|---|---|---|---|---|---
Outdoor Air Supply| FAN6264| –
The outdoor supply kit is designed specifically for SV01 & SV02 systems when
roof cavity air is not desirable.
The kit contains a fixed grille, duct and filter spigots.*
- All other systems include these parts in the standard kit.
Heat Transfer
Seasonal
Add−On| SV01P+
SV02P2
SV01P| SV01L+
SV01L2| SV02E2
SV02P+
SV02P2
SV02P| SV02L+
SV02L2| SV04E2
SV04P+
SV04P2
SV04P| SV04L+
SV04L2| SV06E2| SV06P+
SV06P2
SV06P| SV06L+
SV06L2
---|---|---|---|---|---|---|---|---|---
Heat Transfer| FAN2027| −| FAN2027| −| FAN2028| −| FAN2028
(1 branch)| −|
| FAN4438 (2 branch)
Heat Transfer has a motorised damper that operates to switch the air drawing from either the outside or roof cavity to instead draw air from the room where there is a heat source (usually a lounge) and transfer it to the bedrooms. This seasonal add−on can also provide internal air circulation when roof cavity and/or outside temperatures are too cold. When installing a Heat Transfer seasonal add−on, an adequate heat source is required that is capable of delivering enough excess heat to warm rooms it is transferred to, while remaining effective in the source room.
- It is important to point out that when Heat Transfer is activated, the system is not bringing in fresh air, therefore not ventilating the home – however the home is getting the benefit of transferring heat around the house (e.g. cold winter nights). It also shuts off the air supply back into the heat source room.
Note:
- Heat Transfer is recommended when there is a heat source that creates excess heat (i.e. wood fire or similar).
- A heat pump sized for the room it occupies may not be suitable for Heat Transfer.
- If planning to use a heat pump with Heat Transfer, first consult the heat pump installer/manufacturer.
Positive Pressure Systems Seasonal Upgrades
Tempering Heaters
| Seasonal Add−Ons| SV01P+
SV01P2| SV01P| SV01L+
SV01L2| SV02E2
SV02P+
SV02P2| SV02P| SV02L+
SV02L2| SV04E2
SV04P+
SV04P2| SV04P| SV04L+
SV04L2| SV06E2
SV06P+
SV06P2| SV06P| SV06L+
SV06L2
---|---|---|---|---|---|---|---|---|---|---|---|---|---
Tempering
Heater| 1 kW| DCT3478| DCT1226| −| DCT3478| DCT122| −| DCT3231| DCT1483| −|
DCT3231| DCT1483| −
2 x 1 kW*| −| −| −| | | −
2 kW| −| −| DCT3230| DCT1484| −| | | −
2 x 2 kW**| −| −| −| DCT4613| −| −
- DCT1491 and DCT3418 consist of 2 x 1kW heaters for installation into each branch of an SV06P, SV06P2, SV06P+ or SV06E2 system.
**DCT4613 consists of 2 x 2 kW heaters for installation into each branch of an SV06P2, SV06P+ or SV06E2 system.
A Tempering Heater is a 1kW or 2kW element inline heater designed to take the chill off incoming air.
- Specified when the ability to temper the delivered air to a more comfortable temperature is required.
- Tempering heaters will not provide a home heating solution.
- Using a 1kW heater, the temperature of the introduced air can be raised by up to 8°C. The temperature of the home will not increase by this much.
- A SmartVent system with an inline tempering heater is not intended to be a substitute for an effective heating system in the home.
Positive Pressure Systems Add−on Kits
Additional Outlets
Kit| SV01P+
SV01P2
SV01P| SV01L+
SV01L2| SV02E2
SV02P+
SV02P2
SV02P| SV02L+
SV02L2| SV04E2
SV04P+
SV04P2
SV04P| SV04L+
SV04L2| SV06E2
SV06P+
SV06P2
SV06P| SV06L+
SV06L2
---|---|---|---|---|---|---|---|---
Additional
Room| 3m Duct| DCT2276| DCT4276| DCT2276| DCT4276| DCT2276| DCT4276| DCT2276|
DCT4276
6m Duct| DCT2667| −| DCT2667| −| DCT2667| −| DCT2667| −
Through
Wall| DCT2286| −| DCT2286| −| DCT2286| −| DCT2286| −
Additional Fans
Kit| SV01P+
SV01P2
SV01P| SV01L+
SV01L2| SV02E2
SV02P+
SV02P2
SV02P| SV02L+
SV02L2| SV04E2
SV04P+
SV04P2
SV04P| SV04L+
SV04L2| SV06E2
SV06P+
SV06P2| SV06P| SV06L+
SV06L2
---|---|---|---|---|---|---|---|---|---
Additional
Fan| 150mm| FAN5836| −| FAN5836| −| FAN5836| −| FAN5836| −
200mm| FAN5837| −| FAN5837| −| FAN5837| −| FAN5837| −
An additional fan kit allows an additional branch with fan, filter and outlet to be fitted to the system. The additional fan kits enable a single controller to operate two systems where longer duct runs or between floor configurations would normally be required.
SmartVent Synergy2
Overview
SmartVent Synergy2 is a centralised energy or heat recovery system that
constantly evaluates the environmental dynamics in and around your home. Four
temperature and humidity sensors measure moisture content throughout the home,
in the roof cavity and outside, to calculate dew point which is the measure of
when condensation will appear on the windows given the internal temperature
and moisture conditions combined with the temperature of the coldest surface.
This comprehensive and clever solution can then determine how much improved
air quality to introduce to effect change without the risk of
over−ventilating. At the heart of these systems the exchange of heat energy
from the outgoing air to the incoming air provides an excellent solution for
homes built
after 2002.
SmartVent Synergy2 Range
Home ventilation system best suited to homes built to modern standards
Model | Description | Product Code |
---|---|---|
SYN1015E2 | 3 supply outlets/1 extract (expandable to 4 outlets/2 extracts*) | |
for homes up to 150m² | FAN6914 | |
SYN2025E2 | 3 supply outlets/1 extract (expandable to 4 outlets/2 extracts*) | |
for homes up to 250m² | FAN6915 | |
SYN3035E2 | 3 supply outlets/1 extract (expandable to 4 outlets/2 extracts*) | |
for homes up to 350m² | FAN6916 |
- Contact SmartVent for design advice if more outlets or extracts are required
System Extensions
Model | Outlet | Extract |
---|---|---|
SYN1015E2 / SYN2025E2 / SYN3035E2 | DCT4015 | DCT4016 |
Extension kits can be used to add more outlets and extracts to your SmartVent
home ventilation system.
Features and Seasonal Add−Ons
Features| SYN1015E2
SYN2025E2
SYN3035E2
---|---
Dew Point Control|
Humidity Sensing|
Temperature Sensing|
Low Temperature Protection|
Auto or Manual Operation|
Core Efficiency (ºC)| Up to 75%
Boost Control|
Filter Change Alert|
Screen Brightness Control|
Scheduler|
Seasonal Add−Ons¹ )
Flexible Air Source − Roof Cavity|
Heat Transfer|
Tempering Heater|
- See page 194 for full information on Seasonal Add−On options
Control Indoor Climate
Reduce moisture, mould and mildew with multiple seasonal add−on options
SmartVent Synergy2
Overview
SmartVent Tempra is a single room heat recovery unit suitable for residential
retrofit and new builds, elderly care facilities, student accommodation,
military barracks and apartments.
SmartVent Tempra meets the performance requirements for continuous ventilation
under the NZ Building Regulations.
With a 100mm diameter heat recovery outlet, these units have low energy
consumption and low noise levels.
Based on a 2.4m stud and 0.35 ACH (as per NZS4303.1990), SmartVent Tempra can
be set to run continuously at 6 l/s (for rooms up to 25m² ) or 9 l/s (for
rooms up to 37m2), boosting up to 13 l/s, recovering energy from the extracted
air and returning it to the dwelling.
The unique, compact heat exchanger has a temperature efficiency up to 80%,
saving energy and reducing your carbon footprint while providing quality
ventilation in situations where a traditional heat recovery ventilation system
is not practical.
SmartVent Tempra Range
Description | Order Code |
---|---|
Standard Tube | FAN4439 |
Long Tube | FAN5945 |
Constant trickle ventilation (24 hours, 7 days) with airflow boost option.
Separated airflows so that extracted moisture extracted is not re−introduced.
Consistently higher heat recovery than units that use “extract−supply cycling”
methods.
Low energy consumption.
Low noise.
Security − reduces risk of theft as windows are not required to be left open.
Can be switched to ‘extract only’ if desired.
Heat Exchanger
Dimensions (mm)
Model | A | B | C | D | E | F | G |
---|---|---|---|---|---|---|---|
FAN4439 | 190 | 266 | 262 | 117 | 321 | 496 | 450 |
FAN5945 | 190 | 266 | 262 | 117 | 461 | 636 | 590 |
Performance
Specification | Trickle − Low | Trickle − High | Boost |
---|---|---|---|
Free Air Performance | 6 l/s | 9 l/s | 15 l/s |
Power | 3.2W | 5.7W | 26.6W |
Sound* | 20 dB(A) | 22 dB(A) | 36 dB(A) |
- Octave band frequency range of 250Hz to 4KHz at 3m. Unit mounted on a reflective surface.
SmartVent Fresh
SmartVent Fresh Range
Description | Order Code |
---|---|
dMVHR Decentralised Mechanical Heat Recovery with App control | FAN7390 |
Wireless e16 wall controller | FAN7391 |
Outdoor Humidity and Temperature sensor | FAN7392 |
Indoor Humidity and Temperature sensor | FAN7393 |
Indoor CO2 sensor | FAN7394 |
Dimensions (mm)
A | B | C | D | E | F |
---|---|---|---|---|---|
270 | Ø160 | 276 | 80 | 140 | 44 |
Heat and Energy Recovery Systems
Selection Guide
Home Ventilation Systems
IMPORTANT
− The information listed above is a guide only. If there is any doubt, please
use our design service
Seasonal Add−Ons | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Second Air Source | DCT4361 | − | |||
Heat Transfer | FAN6905 | − | |||
Tempering Heater | 1 kW | DCT3231 | − | ||
2 kW | DCT3230 | − | |||
Core Bypass | − | Integrated | |||
Add−On Kits | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
--- | --- | --- | --- | --- | --- |
Additional Outlet | DCT4015 | DCT4363 | DCT2334 | ||
Additional Extract | DCT4016 | DCT4362 | DCT2335 | ||
Additional Fans | FAN7017 | FAN7018 | FAN7019 | − |
These recommendations are based on the standard components in the system.
− This selection guide assumes 2.4m stud height, if greater please increase
the square metre size by 4% for every 0.1 metre (e.g. for a 2.8m stud height,
increase your house size by 16%).
− If you choose to exceed the number of rooms listed in the selection guide
above, the performance of the system will be affected.
− Ensure that there is sufficient ceiling space to install all componentry.
− By adding additional outlets to the system the air is being divided amongst
more rooms.
− Extra duct may be required depending on the size and layout of the home (see
Accessories on page 196).
− For larger homes, or advice on adding outlets or extracts, please contact
SmartVent for technical advice on 0800 140 150.
Controllers & Componentry
Recovery Core Types
Specifications
Specifications| SYN1015E2| SYN2025E2| SYN3035E2| BAL225|
BAL405
---|---|---|---|---|---
Fan Type| AC Centrifugal| AC Centrifugal| AC Centrifugal| EC Centrifugal| EC
Centrifugal
Max. Fan Cores| 2| 2| 2| −
Spigot Size| 150mm| 150mm| 150mm| 125mm| 150mm
Fan Speeds| 3| 3| 3| 10| 10
Max. Air Flow per Fan @ 0 Pa| 55 l/s, 198m3/hr| 84 l/s, 301m3/hr| 122 l/s,
440m3/hr| 76 l/s, 275m3/hr| 136 l/s, 490m3/hr
Max. Air Flow per Fan @ 150 Pa| 29 l/s, 106m3/hr| 51 l/s, 183m3/hr| 93 l/s,
333m3/hr| 62 l/s, 223m3/hr| 110 l/s, 395m3/hr
Max. Static Pressure per Fan| 263 Pa| 308 Pa| 401 Pa| 380 Pa| 600 Pa
Power Supply| 220−240V AC
50 Hz| 220−240V AC
50 Hz| 220−240V AC
50 Hz| 220−240V AC
50 Hz| 220−240V AC
50 Hz
Total Input Power| 95W| 136W| 215W| 128W| 173W
Current (A)| 0.45A| 0.66A| 1.03A| 0.58A| 0.79A
Operating Temp| −10ºC to 40ºC| −10ºC to 40ºC| −10ºC to 40ºC| −20ºC to 45ºC|
−20ºC to 45ºC
Sound Level| 31.5 dB(A)| 34 dB(A)| 37 dB(A)| 39 dB(A)
Energy Recovery Core Dimensions (mm)| A| B| C
---|---|---|---
SYN1015E2| 220| 625| 750
SYN2025E2| 220| 650| 820
SYN3035E2| 230| 770| 960
Heat Recovery Core Dimensions (mm) | A | B | C |
---|---|---|---|
BAL225 | 285 | 550 | 550 |
BAL405 | 524 | 745 | 776 |
Heat and Energy Recovery Systems Seasonal Upgrades
Roof Cavity Air Supply
Seasonal Add−On | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Second Air Source | DCT4361 | − |
Roof Cavity Air Supply is an optional second air intake located in the roof cavity. This seasonal add−on allows the system to utilise the roof cavity temperature for increased air source flexibility.
Heat Transfer
Seasonal Add−On | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Heat Transfer | FAN6905 | − |
Heat Transfer has a motorised damper and external fan that operates to switch
the air drawing from either the outside or roof cavity to instead draw air
from the room where there is a heat source (usually a lounge) and transfer it
to the bedrooms. This feature can also provide an alternative air supply. When
installing a Heat Transfer feature, an adequate heat source is required that
is capable of delivering enough excess heat to warm rooms it is transferred
to, while remaining effective in the source room.
− It is important to point out that when Heat Transfer is activated, the
system is not bringing in fresh air, or extracting stale air, therefore not
ventilating the home − however the home is getting the benefit of transferring
heat around the house (e.g. cold winter nights). It also shuts off any supply
back into the heat source room.
Note:
− Heat Transfer is recommended when there is a heat source that creates excess
heat (i.e. wood fire or similar).
− Heat Transfer can also be used to manage the preferred temperature and
moisture conditions in the home when added to a SmartVent Synergy2 system.
− A heat pump sized for the room it occupies may not be suitable for Heat
Transfer.
− If planning to use a heat pump with Heat Transfer, first consult the heat
pump installer/manufacturer.
Recycle
The Recycle function will recycle inside air around the home when other air
sources are not suitable. The recycle function for SmartVent Synergy2 systems
is a feature of the Heat Transfer upgrade.
Tempering Heater
Seasonal Add−On | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Tempering Heater | 1kW | DCT3231 | − | ||
2kW | DCT3230 | − |
A Tempering Heater is an element in line heater designed to temper the
incoming air.
− Specified when the ability to temper the delivered air to a more comfortable
temperature is required.
− Tempering heaters will not provide a home heating solution.
− The temperature of the introduced air can be raised by up to 8°C. The
temperature of the home will not increase by this much.
− A SmartVent system with an inline tempering heater is not intended to be a
substitute for an effective heating system in the home.
Core Bypass
Model | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Core By−pass | − | Integrated |
This feature diverts fresh filtered air around the core. This is useful in
summer when the outside temperature is assumed to be lower than the inside and
you do not want to warm the incoming air with the air you are extracting from
the home. A Core Bypass is included as standard in Balance BAL225 and BAL405.
− The Core Bypass enables the system to bypass the core in the summer when
heat recovery is not desirable.
In the summer, Core Bypass ensures the coolest possible air is used to
ventilate the home.
Additional Outlets and Extracts
Kits | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Additional Outlet | DCT4015 | DCT4363 | DCT2334 | ||
Additional Extract | DCT4016 | DCT4362 | DCT2335 |
Additional Fans
Kits | SYN1015E2 | SYN2025E2 | SYN3035E2 | BAL225 | BAL405 |
---|---|---|---|---|---|
Additional Fans | FAN7017 | FAN7018 | FAN7019 | − |
An additional fan kit allows an additional branch with fan, filter and outlet to be fitted to the system. The additional fan kits enable a single controller to operate two systems where longer duct runs or between floor configurations would normally be required.
Accessories
Acoustic Insulated Duct
150mm x 3m | DCT0633 |
---|---|
150mm x 6m | DCT0634 |
200mm x 3m | DCT0635 |
200mm x 6m | DCT0636 |
Insulated Duct
150mm x 3m | DCT0583 |
---|---|
150mm x 6m | DCT0584 |
200mm x 3m | DCT0585 |
200mm x 6m | DCT0586 |
Nude Duct
150mm x 3m | DCT0561 |
---|---|
150mm x 6m | DCT0562 |
200mm x 3m | DCT0563 |
200mm x 6m | DCT0564 |
Duct Fasteners
Hanging Strap | DCT2299 |
---|---|
Duct Tape 48mm x 5m | DCT0173 |
Duct Tape 48mm x 30m | DCT0807 |
Duct Connectors
150mm Metal | DCT0723 |
---|---|
200mm Metal | DCT0724 |
Y Branch
150−150−150 | DCT1233 |
---|---|
200−150−150 | DCT0379 |
200−200−200 | DCT0376 |
250−200−200 | DCT0471 |
Branch Take Off
200−200−150 | DCT0877 |
---|---|
250−250−150 | DCT0880 |
Double Branch Take Off
200−150−150−150 | DCT0889 |
---|---|
250−200−150−150 | DCT0891 |
Fixed Louvre Grilles − White Plastic
125mm | DCT0041 |
---|---|
150mm | DCT0063 |
200mm | DCT1089 |
Ceiling Diffuser − Square White Plastic
150mm Flat | DCT2208 |
---|
Extract Diffuser − Round White Plastic
150mm | DCT2610 |
---|---|
200mm | DCT2611 |
Noise Reduction Fan Housing
150/200mm Centrifugal | DCT2297 |
---|---|
150/200mm Mixed Flow | DCT2298 |
Replacement Filters
G4 Sock | DCT1411 |
---|---|
G4 Filter | DCT2221 |
F7 Filter/EU 7 | DCT2093 |
F7 with Carbon Filter | DCT2277 |
HEPA with Carbon Filter | DCT2278 |
Replacement G3 Filters (2 Pack)
for BAL225 | DCT4493 |
---|---|
for BAL405/405 PLUS | DCT4494 |
for SYN190/E/E2 | DCT4495 |
for SYN1015/E/E2 | DCT4496 |
for SYN2025/E/E2 | DCT4497 |
for SYN3035/E/E2 | DCT4498 |
Extension Leads
3m Fan Lead (4−wire) | FAN2190 |
---|---|
3m Heater or Damper Lead (3−wire) | FAN2194 |
PureAir Room 260X
PURIFY YOUR INDOOR AIR FOR A HEALTHIER HOME ENVIRONMENT
Overview
The Vent-Axia PureAir Room provides a safe space for people suffering from
allergies or who want to be sure they are not breathing in harmful pollutants
and wish to improve their indoor air quality. The filters of an air purifier
will remove airborne contamination and allergens such as dust, pollen, animal
dander, dust mites, tobacco smoke, traffic fumes and more. Removing these can
make a positive impact to the indoor air you breathe and therefore help to
improve your health and wellbeing.
Mycotoxins released by mould spores can cause headaches, eczema & lung conditions such as asthma
House hold dust can be an irritant to our skin and lungs. It is also perfect food for dust mites which produce allergens
Bacteria and viruses spread easily around the home in the air causing cold and flu like symptoms
Odour can be unpleasant but odour also caused by pollutants like aerosols and
air fresheners are detrimental health
PureAir Room 260X Range
Description | Order Code |
---|---|
PureAir Room 260X Air Purifier with App Control | FAN7450 |
PureAir Room 260X Replacement Filter | DCT4615 |
Technical
Supply | 220−240V AC, 50Hz | Noise Range | 27-45 dB(A) |
---|---|---|---|
Rated Power | 60W | Dimensions (WDH): | 350 x 230 x 560mm |
Air Flow Rate | 260m³/h | Weight | 5.8 kg |
Timer | 1-8 hours | Room size | 30m² |
Advanced 6 Stage Filtration System
Documents / Resources
|
SmartVent Evolve2 Home Ventilation
Systems
[pdf] Instruction Manual
Evolve2 Home Ventilation Systems, Evolve2, Home Ventilation Systems,
Ventilation Systems, Systems
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>