MSRGEAR Guardian Purifier Instruction Manual
- June 12, 2024
- MSRGEAR
Table of Contents
- TIPS
- KNOW YOUR MSR ® GUARDIAN™ PURIFIER
- GUARDIAN™ PURIFIER OPERATING INSTRUCTIONS
- PURIFIER INTEGRITY TEST
- PURIFIER INTEGRITY TEST FIELD MAINTENANCE
- SPECIFICATIONS
- TROUBLESHOOTING
- **** WARNING
- LIMITED WARRANTY/LIMITATIONS OF REMEDIES AND LIABILITY
- PURIFIER CARE AND MAINTENANCE
- HOW IT WORKS
- CUSTOMER SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MSRGEAR Guardian Purifier
TIPS
WATER COLLECTION AND PREPARATION
Use the cleanest, clearest water available.
STORAGE
DO NOT disassemble and attempt to dry out Filter Cartridge. A dry cartridge
will not work properly.
Pump out any excess water from the Purifier prior to storing it.
PREFILTER
The Prefilter is designed to draw water from just below the surface, where
it’s cleanest. Position the Dual Hose and Float such that the Prefilter’s mesh
cage floats vertically under the Float.
In some cases, the mesh cage may rotate partially out of the water. This is OK. The cage is designed to draw water even when it’s partially submerged.
If the mesh becomes clogged with debris, swirl it in water and brush the dirt off. If dirt becomes trapped inside the mesh, remove the Prefilter by gently twisting and pulling it from the Inlet Hose. Then, rinse the dirt out.
IN FREEZING TEMPERATURES
DO NOT pump the Purifier if its Filter Cartridge is frozen. The cartridge MUST
be fully thawed before pumping.
KNOW YOUR MSR ® GUARDIAN™ PURIFIER
GUARDIAN™ PURIFIER OPERATING INSTRUCTIONS
PREPARE PURIFIER
- Uncoil the Dual Hose and place Prefilter in water.
- Remove RED Clean Side Cover and pump 5-10 strokes to ensure clean-tasting water.
WARNING – DO NOT pump water over 160˚F (71˚C). DO NOT pump if purifier is frozen. These actions could damage the purifier.
PURIFY WATER
- Attach threaded container to threaded bottom of purifier. Or, a hose may be attached to the Clean Water Port.
- Pump to purify water (~60-80 strokes/min. is optimal).
PACK AND STORE PURIFIER
- Detach container and remove Prefilter from water.
- Pump the Handle to purge excess water from purifier.
- Replace Clean Side Cover & wrap Dual Hose.
WARNING – DO NOT disassemble and attempt to dry out the Filter Cartridge. See “Replacing the Filter” for more information.
PURIFIER INTEGRITY TEST
The Guardian Purifier withstands freeze- and drop-testing (6 ft. to concrete), but if you believe the Filter may have been compromised, an integrity test should be performed, and can be done in the field. A CLEAR, THREADED WIDE- MOUTH BOTTLE MUST BE CARRIED TO PERFORM THE TEST. Read all steps first.
INSTRUCTIONS:
- Uncoil Dual Hose and place Prefilter in a water source.
- Remove Clean Side Cover and attach clear, threaded bottle to bottom of purifier.
- Pump Handle to fill about 1/3 of the bottle with water.
- Remove the Prefilter from the water source and disconnect Dual Hose.
STOP. READ STEPS 5-7 BEFORE PROCEEDING.
-
With threaded container attached, orient pump upside down, and face Inlet/Outlet Barbs away from you; water will be exiting them. Pump Handle 5-10 strokes until only air exits the Outlet Barb. (A little water will drip from the bottle.)
-
Plug Outlet Barb (the smaller hole) by securely placing a finger over it. Pump 5-10 complete strokes (one stroke = complete pump in and out).
-
Keeping Outlet Barb plugged, observe water in bottle for 30 seconds: If a steady stream of air bubbles exits the Clean Water Port, the purifier is NOT SAFE to use. If a few bubbles escape, pump the Handle 5 more strokes and observe another 30 seconds. If no subsequent bubbles escape, the pump is safe.
If your Filter Cartridge has been compromised, please purchase a replacement at msrgear.com.
PURIFIER INTEGRITY TEST FIELD MAINTENANCE
The MSR Guardian Purifier is designed to be serviceable in the field. Please
purchase the Annual Maintenance Kit for replacement parts, available at
msrgear.com.
WARNING
Disassembling the Purifier can expose you to contaminated parts, resulting in sickness. MSR recommends sterilizing the Purifier before any disassembly. If you cannot sterilize the Purifier, wash your hands thoroughly after disassembly.
PUMP HEAD MAINTENANCE
DISASSEMBLY:
- Remove Handle Pin (pinch, then push) and Handle Pin Sleeve.
- Remove Pin & Pin Clip. Set Handle aside.
- Unthread Piston End Nut and remove Piston assembly.
- Separate Piston from Piston End Nut.
- Remove Umbrella Valve by lifting it out with your finger.
- Note orientation of Cup Seal. Remove all seals (Cup Seal, Piston O-ring, End Nut O-ring).
- Rinse all parts with clean water.
ASSEMBLY :
-
Using finger, firmly insert stub end of Umbrella Valve into center hole of Piston Cavity.
-
Install new End Nut O-ring and Piston O-ring. Apply a thin layer of MSR Silicone Lubricant to each.
-
Install new Cup Seal onto Piston in the same orientation as old Cup Seal.
Apply a thin layer of Lubricant to Cup Seal and the inside walls of Piston Cavity. -
Slide Piston End Nut onto Piston.
-
Thread Piston End Nut into Piston Cavity until rotation stops completely.
-
Reattach Handle with Handle Pin Sleeve and Handle Pin.
-
Align Piston to Handle and reinstall Pin & Pin Clip. Confirm that end of Pin Clip is clipped onto Pin.
PRESSURE RELIEF VALVE AREA MAINTENANCE
DISASSEMBLY:
- By hand or using a coin, push and rotate Relief Valve Assembly 1/3 rotation.
- Carefully slide Relief Valve Assembly from cavity.
- Remove Relief Valve O-ring.
- Rinse Relief Valve Assembly with clean water to remove debris.
- Flush Relief Valve Cavity with clean water. DO NOT place objects in the Relief Valve Cavity.
ASSEMBLY:
- Replace Relief Valve O-ring and apply a thin layer of Lubricant to it.
- Verify that the rubber end surface of the Relief Valve Assembly is clean of debris.
- Reinstall Relief Valve Assembly by pushing while rotating it until its arrow aligns with the arrow and lock symbol on the Pump Housing.
SPECIFICATIONS
Kit Contents| Guardian Purifier
Instruction Manual Storage Sack
---|---
Weight| 17.3 oz. / 490 g
Dimensions| 8.2 x 4.7 in. / 21 x 12 cm
Flow Rate| 2.5 liters per minute
Hollow Fiber Filter| Up to 10,000+ liters (depends on water conditions)
Patents| U.S. patent pending
TROUBLESHOOTING
Problem | Cause | Solution |
---|---|---|
Decreased/no water flow, or hard to pump | Clogged Prefilter | Rinse/Clean |
Prefilter
Clogged Filter| Replace Filter Cartridge (See Replacing Filter)
Hose kinked| Straighten hose
Limp Handle ( PULL stroke| Damaged Cup Sea| Damaged Cup Seal; replace if
necessary. (See Pump Head Maintenance)
Limp Handle ( PUSH stroke)| Piston End Nut leaks| Clean Piston End Nut, End
Nut; O-ring and Piston O-ring. (See Pump Head Maintenance)
Damaged or loose Umbrella Valve| Clean Umbrella Valve; replace if necessary.
(See Pump Head Maintenance)
Lots of water exiting Dirty Water Outlet Hose with little water exiting Clean
Water Port| Pressure Relief Valve (PRV) is contaminated| Clean Relief Valve
Assembly; replace O-ring if necessary. (See Relief Valve Area Maintenance
Clogged Filter| Replace Filter Cartridge
**** WARNING
BIOLOGICAL HAZARD
There are hazards associated with backcountry or international travel and the use of water purifiers. Drinking untreated water can result in exposure to harmful microorganisms and an increased risk of gastrointestinal illness. Using this purifier improperly increases your risk of exposure to harmful microorganisms and increases your risk of gastrointestinal illness. Reduce your chances of becoming sick by following the warnings and instructions in this manual and educating yourself on backcountry and international water safety.
YOU ARE RESPONSIBLE FOR YOUR OWN SAFETY AND THE SAFETY OF THOSE IN YOUR GROUP. PLEASE USE GOOD JUDGMENT.
Never use the Guardian purifier to filter seawater or chemically contaminated water, such as water from mining tailing ponds or near agricultural operations. The Guardian purifier does not make potable water from these sources and does not remove chemicals and radioactive materials, or particles smaller than 0.02 microns.
Keep the Inlet Hose and other potentially contaminated parts away from purified water to prevent cross contamination.
READ, UNDERSTAND, AND FOLLOW ALL instructions and warnings in this manual before using this purifier. Failure to follow warnings and instructions may result in gastrointestinal illness.
IMPORTANT
Read and understand this entire manual carefully before assembling or using
this water purifier. Keep this manual for future reference. If you do not
understand this manual or have any questions, please call Cascade Designs at
1-800-531-9531.
LIMITED WARRANTY/LIMITATIONS OF REMEDIES AND LIABILITY
Limited Warranty. Cascade Designs, Inc. (“Cascade”), to the original owner (“Owner”), under intended use and maintenance, warrants the enclosed product (“Product”) to be free from defects in materials and workmanship. No warranty against defects in materials and workmanship applies if Product is: (i) altered in any way; (ii) used for purposes inconsistent with Product’s intended purpose or design; or (iii) improperly maintained. Warranty is furthermore voided where Owner: (i) fails to follow Product instructions or warnings; or (ii) subjects Product to misuse, abuse, or neglect.
Product parts determined by Cascade to be defective in materials or workmanship will be repaired or replaced as Owner’s sole remedy. Cascade reserves the right to replace any discontinued product with a new product of comparable value and function. A returned product deemed irreparable becomes the property of Cascade and will not be returned.
EXCLUDING THE LIMITED WARRANTY PROVIDED ABOVE, CASCADE, ITS AFFILIATES AND THEIR SUPPLIERS, TO THE MAXIMUM EXTENT PERMITTED BY LAW, MAKE NO WARRANTIES, EXPRESSED OR IMPLIED, AND DISCLAIM ALL WARRANTIES, DUTIESAND CONDITIONS, WHETHER EXPRESSED, IMPLIED, OR STATUTORY, WITH RESPECT TO THE PRODUCT, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, AGAINST LATENT DEFECTS, FITNESS FOR A PARTICULAR PURPOSE, OR CORRESPONDENCE TO DESCRIPTION.
Warranty Service. To obtain service under this warranty, the warranty-eligible Product must be presented to a Cascade authorized dealer. In the United States and Canada, warranty service may also be obtained by calling 1.800.531.9531 [M-F, 8:00-4:30, PDT]. Owner is responsible for all costs associated with returning Product to Cascade for service. Where, at its sole discretion, Cascade deems Product eligible for warranty repair or replacement, Cascade will pay the shipping and handling associated with returning repaired or replaced Product to Owner. In instances where Cascade deems a returned product ineligible for warranty service, Cascade will, if possible, repair product for a reasonable charge that includes return shipping and handling.
Limitation of Remedies. Should a court of competent jurisdiction find the limited warranty breached, Cascade’s only obligation will be to, at its option, either repair or replace Product. Should the aforementioned remedy fail of its essential purpose, Cascade will, in exchange for return of Product, refund to Owner Product’s original purchase price. THE FOREGOING REMEDY IS THE SOLE AND EXCLUSIVE REMEDY OF THE PURCHASER AGAINST CASCADE, ITS AFFILIATES, AND THEIR SUPPLIERS, REGARDLESS OF LEGAL THEORY.
Limitation of Liability. Cascade’s, its affiliates’, and their suppliers’
maximum liability is limited to incidental damages not to exceed the original
purchase price of the Product.
CASCADE, ITS AFFILIATES AND THEIR SUPPLIERS HEREBY DISCLAIM AND EXCLUDE ANY
LIABILITY FOR ANY CONSEQUENTIAL OR OTHER DAMAGES RESULTING FROM ANY REASON
WHATSOEVER. THIS EXCLUSION AND LIMITATION APPLIES TO ALL LEGAL THEORIES UNDER
WHICH DAMAGES MAY BE SOUGHT, AND WILL APPLY EVEN IF ANY REMEDY FAILS OF ITS
ESSENTIAL PURPOSE.
This limited warranty gives you specific legal rights; you may have additional rights which vary state to state.
Always completely follow safety, use, operation, and maintenance instructions for this or any other Cascade product.
European Union customer statutory rights are not affected.
PURIFIER CARE AND MAINTENANCE
To keep your Guardian Purifier performing reliably for many years, service your purifier using the Annual Maintenance Kit, available at msrgear.com.
STORAGE
Before storage, pump out any excess water and attach the Clean Side Cover. DO NOT disassemble and dry the Filter Cartridge. A dry cartridge will not work properly. (Please contact MSR customer service if you suspect your filter has dried out.)
Towel dry the outside of the pump. Gently rub off any debris from the Prefilter and rinse it with fresh water.
Before or after long-term storage, sterilize the purifier to ensure fresh-
tasting
water (see “Sterilizing the Purifier”).
STERILIZING THE PURIFIER
When to sterilize: Sterilize the Purifier before and/or after long-term storage to ensure long life and fresh-tasting water. Also sterilize it before any disassembly.
- Mix a solution of 2 mL (~1/2 tsp) of household bleach (free of dyes or perfumes) with 2 L of water, or dissolve 12 MSR Aquatabs® tablets in 2 L of water.
- Pump most of this solution through the purifier, stopping before air can enter the pump.
- Wait 30 minutes.
- Pump 1-2 liters of clean water to clear any remaining solution from pump.
- Pump the Handle to purge excess water from the Purifier.
WARNING
Disassembling the Purifier can expose you to contaminated parts, resulting in sickness. MSR recommends sterilizing the Purifier before any disassembly. If you cannot sterilize the Purifier, wash your hands thoroughly after disassembly.
REPLACING THE FILTER CARTRIDGE
The Guardian Purifier’s Hollow Fiber Filter has been tested to over 10,000 liters. When to replace: The Filter Cartridge should be replaced when the flow rate drops to less than 1L /min. when pumping 70 strokes per minute. The filter is still purifying water, but more wear occurs on internal parts as the flow rate drops.
DISASSEMBLY
- Unthread the Filter Base from Pump Housing.
ASSEMBLY
- Lightly lubricate the Filter Cartridge O-ring and Filter Base O-ring.
- Thread the Filter Base into the Pump Housing. Don’t over tighten. The Filter Base is designed to stop rotating when it’s fully threaded.
HOW IT WORKS
The Guardian Purifier’s Hollow Fiber Filter removes pathogens and other particles through size exclusion purification. This is the most reliable means of purification because the fibers’ pores physically block pathogens,including viruses. Pressure forces clean water through the walls of these fibers. The microbes and dirt left behind are pumped out through the Dirty Water Outlet Hose.
Other purifiers rely on chemicals or UV light to kill pathogens, or adsorption (such as carbon) to attract them. While these methods can be effective in clear water, the Guardian Purifier is reliably effective in all water types – clear, turbid, tea colored or muddy.
The Guardian Purifier also uses a patent-pending system to self-clean with every stroke. It does not require in-field cleaning to maintain flow.
CUSTOMER SUPPORT
RECYCLED | RECYCLABLE
Printed on recycled paper containing 30% post-consumer waste.
Cascade Designs, Inc.
4000 First Avenue South, Seattle, WA 98134 USA
1-800-531-9531 or
206-505-9500
Cascade Designs, Ltd.
Dwyer Road, Midleton, County Cork, Ireland
(+353) 21-4621400
www.msrgear.com
For product information and service contact
Cascade Designs, Inc.
4000 First Avenue South, Seattle, WA 98134 USA
1-800-531-9531 or
206-505-9500
www.msrgear.com
info@cascadedesigns.com
References
- MSR | Mountain Safety Research: Backpacking, Camping & Mountaineering
- MSR | Mountain Safety Research: Backpacking, Camping & Mountaineering
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>