ROLAIR PMP11MK256FC Portable Air Compressor Owner’s Manual
- June 12, 2024
- ROLAIR
Table of Contents
PORTABLE AIR COMPRESSOR
OWNER’S MANUAL
PMP11MK256FC Portable Air Compressor
MODEL: FC250090L
SERIAL NUMBER:
Thank you for purchasing a ROLAIR!
If after reading this manual you have any questions whatsoever on the proper
installation, operation, or maintenance of your air compressor please feel
free to contact our Customer Service Department at
1-800-310-3573.
We would love to hear from you! PARTS
Genuine ROLAIR replacement parts are sold nationwide through a network of
authorized dealers and service centers. Please contact the dealership where
your air compressor was purchased or our factory Customer Service Department
if you need help troubleshooting, obtaining parts, or locating an authorized
ROLAIR service representative.
To order replacement parts:
- Give compressor model number
- Give compressor serial number
- Name of part
- Part number
- Quantity required
RECORD OF PERTINENT INFORMATION
Make a permanent record of the model and serial number of your new air
compressor here. You’ll save time and expense by including this reference
information when requesting service or replacement parts.
Place & Date of Purchase | Volts | |
---|---|---|
Model | HZ | |
Serial # | HP |
INTRODUCTION
Congratulations on the purchase of your new ROLAIR air compressor!
With over 50 years experience building ROLAIR air compressors specifically
designed for the professional, Associate Engineering Corporation has earned a
reputation for providing a product unsurpassed in quality and reliability. We
are committed to continuing this tradition by analyzing and adapting to the
changing needs and rigorous demands of your industry. You can depend on ROLAIR
because they are built to last.
This manual was compiled for the benefit of the operator. Do not use or allow
anyone else to use your air compressor until this manual is read and all
safety/operating instructions are understood. By reading and following the
instructions contained in this manual, you can achieve years of trouble free
service from your new air compressor. If you have any additional safety or
operating questions after reading this manual, please contact your distributor
or our customer service department. Do not remove or paint over any of the
warning decals attached to the compressor. If any warning decal is missing or
unable to be read, discontinue use and contact us for a free replacement
(1-800-310-3573).
Definitions — Safety Warnings
Safety symbols are used throughout this manual to alert you to imminently
hazardous and potentially hazardous situations. The following definitions
describe the level of severity for each signal word.
DANGER:
Indicates an imminently hazardous situation which, if not avoided, WILL
result in death or serious injury.
WARNING:
Indicates a potentially hazardous situation which, if not avoided, COULD
result in death or serious injury.
CAUTION:
Indicates a potentially hazardous situation which, if not avoided, MAY result
in minor or moderate injury or damage to the air compressor, or other
property.
WARNING: Do not start, operate, or service this machine until you read
and fully understand owner’s manual. Failure to do so could result in death or
serious injury. If you have any questions, call us toll free at
1-800-310-3573.
WARNING: CONTAINS LEAD. May be harmful if eaten or chewed. May generate
dust containing lead. Wash hands after use. Keep out of reach of children.
WARNING: This product can expose you to chemicals including lead, which
is known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
SAVE THESE INSTRUCTIONS! DANGER: RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Electrical components within the motor and pressure switch will spark. This
is normal. If
electrical sparks from the compressor come into contact with flammable vapors,
they may
ignite, causing fire or explosion.| • Always operate the compressor in a well-
ventilated area away from any flammable
vapors, liquid, paint, gasoline, or any other combustible material.
• Always locate compressor at least 20 ft. (6.1m) away from work area if
spraying flammable materials.
• Store flammable materials in a secure location away from the compressor.
•Inadequate ventilation, or restrictions to any of the compressor’s
ventilation openings, will
cause serious overheating and could cause a fire.| • Never place objects
against or on top of an air compressor.
• Always operate air compressor at least 18″ away from any wall or
obstruction.
• Always operate in a clean, dry, and well- ventilated area.
• Unattended compressors with leaks in the unit or air system could start
unexpectedly and
repeatedly and could result in overheating, fire, and personal injury or
property damage.| • Always remain in attendance with the compressor when it is
operating.
• Always turn off and unplug the compressor when it is not in use.
• A fire can occur if spilled gas or vapors come into contact with hot engine
parts, lit cigarettes,
or other sources of ignition.| • Never attempt to fill the gas tank while the
engine is hot or running.
• Add fuel outdoors and in a well-ventilated area.
• Do not fill gas tank near lit cigarettes or near other sources of ignition.
DANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Air from your compressor is not safe for breathing and may contain carbon
monoxide, toxic vapors, or solid particles. Serious injury or death may occur
from inhaling the compressed air from your air compressor.| • Never inhale
compressed air directly from the pump, tank, receiver, or breathing device
connected to the air compressor.
• The compressor is not equipped with suitable filters and in-line safety
equipment for human consumption. Do not use discharge air for breathing.
• Sprayed materials such as paint, stucco, insecticides, solvents, etc. may
contain harmful vapors and poisons.| • Operate compressor and perform work
only in a well-ventilated area. Read and follow the safety instructions
provided on the label or safety data sheets for the materials you are
spraying.
Always use certified safety equipment designed for your specific application.
• For gas-powered compressors, engine exhaust fumes contain poisonous carbon
monoxide which is odorless and colorless. Inhaling those fumes could lead to
serious injury or death.| • Operate compressors only in well-ventilated areas.
Avoid inhaling engine exhaust fumes, and never run a small gas-powered engine
in a closed building or confined area without
adequate ventilation.
WARNING: RISK OF BURSTING
AIR TANK: Air tanks do not have an infinite life and should be inspected
once every year to ensure they are still safe for use. To find your state
pressure vessels inspector, look under the Division of Labor and Industries in
the government section of a phone book or call us toll-free at
1-800-310-3573 for assistance.
The following conditions could lead to a weakening of the air tank, and result
in a violent air tank explosion:
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Failure to properly and regularly drain condensed water from the air tanks
will lead to rust and thinning of the steel air tank can lead to a violent air
tank explosion.| • Drain tanks daily or after every 4 hours of use. If a tank
develops a leak, replace it immediately
with a new air tank, or new complete compressor.
• Modifications, alterations, or attempted repairs made to the air tank can
lead to a violent air tank explosion.| • Never drill into, dent, weld, patch,
or modify the air tank, or its attachments in any way. If you
are in possession of a tank in which it appears any of those conditions exist
or were attempted, discontinue use and replace air tank immediately.
• Never attempt to repair a damaged or leaking air tank. Replace with a new
tank immediately.
• Unauthorized modifications to the safety valve, pressure switch, pilot
unloader valve, or any other component which controls air tank pressure can
lead to a violent air tank explosion.| • The air compressor is designed to
safely operate and withstand specific factory set pressure.
Never make adjustments or parts substitutions to components that control air
tank pressure or factory set operating pressures.
• Do not make alterations to the factory operating pressure settings.
• Before starting, and with air tank pressure at zero, pull the ring on the
safety valve to make sure it moves freely.
• Never operate without a factory approved safety valve.
Attachments & Accessories:
• Exceeding the pressure rating of air tools, spray guns, accessories, tires,
or any other inflatables can cause them to explode or fly apart.| • Do not use
air tools or attachments before reading the owner’s manual to determine the
safe maximum pressure rating.
• Never exceed the manufacturer’s maximum allowable pressure ratings.
• Never use the compressor to inflate small low pressure objects such as
children’s toys, balls, etc.
DANGER: RISK OF INJURY OR PROPERTY DAMAGE WHEN TRANSPORTING OR STORING
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Oil from the compressor can leak or spill and could result in fire or
breathing hazard; serious injury or death can result. Oil leaks will damage
carpets, paint, or any other surfaces.| • Always keep compressor level and
never lay on its side. When transporting, always place compressor on a
protective mat to prevent against damage from leaks. Always remove compressor
from vehicle immediately upon
arrival at your destination. If an oil leak is found, follow all local safety
codes for cleanup of hazardous materials.
WARNING: RISK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Electrical Grounding: Failure to provide adequate grounding to the
compressor could result in serious injury or death from electrocution.| •
Always make certain that the electrical circuit to which the compressor is
connected provides proper electrical grounding, correct voltage, and adequate
fuse protection. If you are unsure, or have any questions about proper
electrical grounding, correct voltage, or adequate fuse protection please call
us toll-free at 800-310-3573.
• Your air compressor is powered by electricity. Like any electrically powered
device, if it is not used properly it may cause electric shock.| • Never
operate the compressor outdoors when it is raining, snowing, or in wet
conditions.
• Never let your electrical cord lay in water.
• Never operate the compressor with a damaged power cord, or with protective
covers damaged or removed.
• Never touch plug with wet hands.
• Never pull on electric cord to disconnect from the outlet.
• Serious injury or death can occur if repairs are attempted by unauthorized
personnel.| • Any electrical repairs or wiring performed on this compressor
should only be performed by ROLAIR authorized service personnel and in
accordance with all national and local electrical codes.
WARNING: RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Serious injury and property damage can occur from loose debris being
propelled at high speeds from the compressed air stream.| • Always wear
certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA 794.3) with
side shields when using the compressor.
• Never direct the air stream, nozzle, or sprayer towards any part of your
body, other people, or animals.
• Always turn off the compressor and drain tank pressure completely before
attempting maintenance or attaching air hose or tools.
WARNING: RISK OF HOT SURFACES
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Serious burn injuries can result from touching exposed metal parts such as
the engine or motor, pump, or any part of the copper/braided discharge lines
and components. These parts will become hot during operation and stay hot
for an extended period of time even after the compressor is shut down.| •
Never touch any of the exposed metal parts during operation and for an
extended period of time after shut down.
• Do not reach around shrouds or attempt any maintenance until the unit has
been allowed to completely cool.
WARNING: RISK FROM MOVING PARTS
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Serious injury or death can occur if moving parts such as belts, flywheels,
pulleys, or fans come into contact with you or your clothing.| • Prior to
operation, always make sure all protective guards and covers are in good
condition, and never operate the compressor if any guard or cover has been
removed or damaged.
• Always keep your hair, jewelry, clothing, and gloves away from moving parts
as they can be caught.
• It is common for air vents to cover moving parts, so they should be avoided
as well.
• An electric air compressor can restart at any time when plugged in, and an
unexpected startup can result in serious injury, death, or property damage.| •
Always unplug the compressor when not in use.
• Always drain air tank pressure completely before attempting any repairs or
maintenance.
• Never allow children or adolescents to operate the air compressor.
• Attempting to operate the compressor with any damaged or missing parts,
protective guards, shrouds, or covers will expose you to moving parts and can
result in serious injury or death.| • Any repairs to the air compressor must
only be made by ROLAIR factory authorized personnel.
WARNING: RISK FROM LIFTING
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Serious injury can result from attempting to lift an object that is too heavy.| • Always obtain assistance from others before attempting to lift any object that is too heavy for you.
WARNING: RISK OF FALLING
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• A compressor may vibrate and move during the course of normal operation resulting in a fall from a table, workbench, roof, or other platform causing damage to the compressor, property damage, and could result in serious injury or death to anyone nearby.| • Always operate air compressor in a stable and secure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use air hose to reach high locations.
WARNING: RISK FROM NOISE
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Under some conditions and duration of use, oise from this product may contribute to hearing loss.| • Always wear certified safety equipment: ANSI $12.6 (S3.19) hearing protection.
WARNING: RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Serious injury or death can occur to you or others if air compressor is used
in an unsafe manner.| • Review and understand all instructions in your owner’s
manual.
• Know how to stop the air compressor at all times.
• Do not operate until you are thoroughly familiar with all of the controls.
• Do not operate the compressor if you are fatigued, under the influence of
alcohol or drugs, or in any other state which might impair judgment.
• Stay alert while operating the compressor and pay close attention to the
task at hand.
CAUTION: RISK OF DAMAGE TO AIR COMPRESSOR OR PROPERTY
WHAT CAN HAPPEN | HOW TO AVOID IT |
---|
• Failure to transport or operate the compressor properly may result in major
repair expenses.| • Check oil levels daily and maintain proper oil levels.
• Always operate compressor in a secure and level position.
• Do not operate without an air filter or in a corrosive environment.
FOR GAS ENGINE POWERED AIR COMPRESSORS — Please note that your gas powered air compressor may not be equipped with a spark arresting muffler. If the compressor is operated around flammable materials or agricultural crops, brush, forests, and grasslands, an approved spark arrestor must be installed, maintained and in good working order. An approved spark arrestor is legally required in the state of California under sections 4442 and 4443 of the California Public Resources Code Statute section 130050. Check your local and state regulations to determine if a spark arrestor is needed for your area of operation.
SYSTEM CONTROLS
-
SAFETY-RFI IEF VALVE Every ROLAIR air compressor is equipped with a safety-relief valve which is designed to discharge tank pressure at a predetermined setting when a systems failure occurs. Check the safety valve daily by pulling on the ring only when the tank pressure is completely drained. The spring loaded valve should move freely within the safety valve body. An inoperable safety valve could allow an excessive amount of tank pressure to build causing the air tank to violently rupture or explode.
Do not tamper with or attempt to eliminate the safety relief valve. -
MANUAL OVERLOAD / MOTOR RESET Every ROLAIR electric air compressor is built with manual overload protection. If the motor overheats, the overload sensor will trip the reset button to protect the motor. If this occurs, please allow the motor to cool for approximately five minutes. Locate and push in the reset button. The use of an undersized or excessive length of extension cord may be the cause of overheating. Re-evaluate the power source and gauge/length of extension cord being used. (Refer to chart on page 10)
-
PRESSURE SWITCH Most electric air compressors are operated by the use of a pressure switch. Always make sure the lever is in the “Off” position before plugging in the power cord. By moving the lever to the “On/Auto” position, the compressor will start and stop automatically within the settings of the pressure switch which are typically 95 — 125 PSI. Do not attempt to stop the compressor Jayunpluggiagthe power cord. To stop, simply move the lever to the “Off” position. The lever operates a relief valve that dumps off head pressure and allows the compressor to restart without load the next time it is used.
-
REGULATOR – WORKING PRESSURE To adjust the output/line pressure, simply lift up on the regulator adjustment knob and rotate clockwise to increase working pressure or counterclockwise to decrease. Push adjustment knob back down to lock in setting. Never exceed the manufacturer’s maximum allowable pressure rating of the tool being used or item being inflated.
-
PRESSURE GAUGE(S) Typically, most compressors are designed with a gauge to measure tank or storage pressure and another gauge attached to the regulator that indicates output or working pressure.
-
DRAIN VALVE(S) One or more drain valves are installed to allow moisture to be drained on a daily basis from the compressor storage tank(s). Onen drains carefully and slowly to prevent scale, rust, or debris from becoming expelled at a high rate of speed.
-
AIR INTAKE FILTER Air intake filters are installed to prevent foreign matter from entering the engine or compressor pump. Check intake elements on a regular basis and either clean or replace as needed. Warm soapy water or low compressed air may be used to clean the elements. Check intake canisters or elbow components for cracks or broken seals and replace if structural problems are found.
-
CHFCK VALVE Every ROLAIRair compressor is built with a check valve to seal off and maintain tank pressure after the top end pressure setting of pilot valve or pressure switch is reached. The check valve works in conjunction with the pressure switch relief valve to provide a loadless start for the compressor system. A quick burst of air escaping from the pressure switch relief valve after an electric unit reaches top end indicates the check valve is working properly. If the compressor has a mysterious leak after stopping that cannot be traced elsewhere, the check valve may require servicing/replacing.
-
VIBRATION DAMPENER(S) The rubber pads installed beneath every portable ROLAIR tank assembly are very important to the proper operation of the air compressor. They provide protection from vibration that left unchecked could cause damage to many system components.
-
QUICK DISCONNECT A universal or 3-way quick disconnect is installed on your air compressor . Simply push a 1/4″ male plug into coupler to snap hose fitting into coupler. Always relieve pressure from coupler before installing or removing hose. See instructions for regulator (#4 above). Pull back on collar to remove air hose after pressure is relieved
-
COID-START VAVLE Most ROLAIR direct-drive air compressors are built with an automatic cold-start valve that allows the motor/pump to warm up before being subjected to tank pressure. Our belt-driven portable units have a manual drain valve installed on the pump aftercooler to assist with cold weather starting. Open drain valve and allow the motor and pump to run unloaded for a minute to warm up. Close the drain and repeat the procedure if the motor or engine continue to struggle.
-
DIPSTICK Prior to daily operation, make a habit of checking the oil level of the compressor pump and engine (if compressor is gas powered). Every direct drive hard carry air compressor has a dipstick to help check and maintain the proper oil level. The dipstick also functions as a crankcase vent. Never operate a direct drive unit without the factory-supplied dipstick.
-
PRFSSURF SWITCH RFI IFF VALVE Most electric air compressors set up to operate start/stop are equipped with a pressure switch relief valve. This valve works in conjunction with the tank check valve to bleed off the compressed air trapped between the pump and check valve after each cycle, allowing for easier restarts. A brief, audible hiss of air at the end of each cycle signifies the valve is working properly. A continuous leak at the relief valve at the end of a cycle would indicate a problem with the check valve. An improperly functioning relief valve/check valve could lead to premature gasket and/or motor failures.
PRE-START CHECKLIST
Read the owner’s manual thoroughly. Make sure that you completely understand all of the safety warnings, system controls and instructions provided before attempting to operate this air compressor. Every effort has been made to provide you with the information needed to obtain many years of reliable and trouble-free service out of your new air compressor. It is your responsibility to operate the air compressor properly. To obtain the longest possible service life from your air compressor you must always keep the following instructions in mind.
-
ALWAYS OPERATE THE COMPRESSOR IN A LEVEL POSITION
All splash-lubricated pumps have a dipper on the bottom of the connecting rod that must remain submerged in the oil bath. Operation at more than a 10 degree angle will cause the pump to seize and void the product warranty -
OPERATE IN A CLEAN, DRY AND WELL VENTILATED AREA
Do not operate in the rain or in areas of standing water. Never operate in an area where other gases, fumes or vapors are present which may become explosive when compressed. Do not operate compressor in an enclosed area. -
CHECK OIL LEVEL DAILY AND CHANGE AT REGULAR INTERVALS
Refer to the maintenance section of this owner’s manual for the correct type/weight of oil to use and how often the oil should be changed. Check oil levels daily. -
INSPECT/CLEAN/CHANGE INTAKE ELEMENTS ON A REGULAR BASIS
The ingestion of dirt into the pump and engine is the primary cause of premature wear. Pay special attention to the intake filters. Check intake filters daily. -
USE LONGER, PROPERLY SIZED AIR HOSE RATHER THAN EXTENSION CORDS
If an extension cord must be used, please refer to the chart below for the proper gauge and maximum length that can be used. The use of inadequately sized air hose will also lead to frictional pressure drops that could affect the proper performance of your air tools. ELECTRIC EXTENSION CORD TABLEMinimum Wire Size
Extension
Cord Length| Motor
1/2 and 3/4 HP| Motor
1, 1-1/2, and 2 HP
Up to 25 ft.| 14 Ga.| 12 Ga.
25 – 50 ft| 12 Ga.| 10 Ga.
50 – 100 ft.| 10 Ga.| 8 Ga. -
DO NOT USE A GENERATOR AS THE POWER SOURCE
Air compressors use inductive motors that require 3-5 times the full-load amp draw to properly start. Most generators will not provide the wattage needed to properly start this type of electric motor. -
CHECK TENSION OF BOLTS AND HARDWARE ON A REGULAR BASIS
Operation of any equipment with loose bolts and/or fittings will lead to excessive vibration and the premature failure of the compressor system control components. -
MAINTAIN RUBBER VIBRATION PADS
Excessive vibration is a major cause of premature compressor failure. Always maintain the rubber vibration pads located beneath tank assembly. Operation without them will void your warranty. -
DRAIN MOISTURE FROM AIR TANKS DAILY
Water is a natural byproduct of compressed air. Drain air tank(s) after each use to combat internal tank corrosion. Keep drain valve(s) closed if storing compressor for any length of time.
SPECIFICATIONS
FC250090L
Horsepower| 2.0 HP| Tank Capacity| 24 Gallons
Voltage| 120 V| Pump-Up Time (0-125 PSI)| 5:35
Hertz| 60 hZ| Recovery Time (95-125 PSI)| 1:05
Phase| Single| CFM Displacement| 10.1
Motor RPM| 3400| Cu. Ft. Delivered @ 40 PSI| 5.4
Stages| Single| Cu. Ft. Delivered @ 90 PSI| 5.1
Amperage| 14.6| Dimensions (LxWxH in)| 23x28x44
Thermal Protection| Manual| Weight| 160 lb
Factory Settings| 95-125 PSI| Noise Level| 80 dBA
Oil Fill Amount| 12 oz| Duty Cycle| Continuous
OPERATION
WARNING — Your safety and the wellbeing of others during the operation of
every ROLAIR compressor is our main concern. Do not operate or permit anyone
else to operate your air compressor until the information contained in this
manual is read and completely understood. Please contact your distributor or
our customer service department if you have any questions on the proper use of
your air compressor.
WET CONDITIONS: Do not operate your compressor in damp or wet conditions,
or after it has been exposed to rain/sleet/ice/snow or moisture of any kind.
Failure to follow this warning could lead to electric shock and/or rust and
ice forming on critical components, making the compressor dangerous to
operate. Always operate and/or store compressor in a clean, dry location with
good ventilation.
DIRECT-DRIVE ELECTRIC
Establish that the air compressor is ready to operate by reviewing the
topics and information provided in the “Pre-Start Checklist” section of this
manual. Slowly open tank drain to remove any condensate that has accumulated
and keep drain open for a few seconds after starting to warm up motor/pump
assembly. Make sure the pressure switch lever is in the “Off” position before
plugging power cord into a properly grounded outlet. Move pressure switch
lever to the “On/Auto” position to build and automatically maintain top end
tank pressure setting. Rotate regulator adjustment knob counterclockwise until
the gauge attached reads 0 PS| before attaching air hose and accessory. Set
working pressure by rotating regulator adjustment knob clockwise and lock in
working pressure according to specifications provided by the tool
manufacturer. Always use the pressure switch “On(Auto)/Off” lever to start or
stop the air compressor. Never stop the compressor by unplugging it from the
power source. Store compressor in a warm/dry location and perform maintenance
as indicated in manual.
DUTY CYCLE:
Several ROLAIR direct-drive machines, Models FC1500HBP2, FC1500HS3 and JC10,
are rated for 70% duty cycle. If subjected to continuous operation the
internal overload will shut down the motor and only restart when sufficient
cooling has occurred.
FREEZING TEMPERATURES:
Proper fluid maintenance and warm up procedures are mandatory before
attempting to start or operate an air compressor in freezing temperatures.
Water, a natural byproduct of compressed air, could turn into ice and
potentially block air flow into, though, and/or out of the pump, air tank(s),
and air line(s). Drain air tanks/ lines after every use and leave drain valves
open when not in use.
If all, or part, of the compressor may be frozen, you must completely thaw the
compressor before attempting to start. Gradually increase the temperature
above freezing and then drain moisture from the air tanks, intercoolers, and
water traps.
Cold Weather Best Practices:
- Do not attempt to start a frozen compressor. Thaw completely first.
- Store your air compressor in a clean, dry area that stays consistently above freezing temperatures.
- Change the oil in the pump and engine to winter grade (check owner’s manual).
- Prior to starting, open the tank drain(s) and allow the compressor to run for 45-60 seconds with the tank drain(s) open before closing to build tank pressure.
- Using a lubricator with de-icing fluid may also be needed to keep your air lines from freezing up/blocked by ice.
- Contact your ROLAIR dealer or our factory customer service department if you have additional questions.
HIGH-ALTITUDE OPERATION:
Due to a decrease in atmospheric pressure air compressor pumps produce less
CFM at higher elevations. As a rule of thumb the output will decrease
approximately three percent per 1000 feet of elevation. Also, because air at
higher elevations is less dense and does not cool as well, electric motors
cannot be subjected to the full nameplate service factor amp rating and may
need to be upgraded to avoid repeated overheating. Direct drive or hand-carry
compressors built with cold-start valves may need to be modified when operated
in higher elevations. Contact our factory Customer Service Department if your
normally reliable air compressor fails to operate correctly at higher
elevations.
MAINTENANCE
Your new air compressor represents the finest engineering and construction
available. Even the best machinery requires periodic maintenance. Please stick
to the maintenance schedule and consider the suggestions that follow to keep
your compressor in peak condition.
NOTE: Always unplug or shut down your compressor and drain the air tanks
completely before attempting any type of maintenance. Wait for compressor to
cool before servicing.
IMPORTANT: Replace the oil after the first 50 hours of operation.
MAINTENANCE HINTS:
- Use a soap/water solution to check for air leaks.
- Never clean filters with a flammable solvent.
- Retorque head bolts only after pump has cooled.
- Never weld on air tank(s).
- Use heat to loosen Loctite seal on drain valves, engine pulleys, and flywheels before attempting to remove.
LUBRICATION
Prior to each use, make a habil of checking the pump oil level. Most direct-
drive air compressors have a dipstick with casting marks that indicate the
minimum and maximum acceptable levels of oil.
Do not operate the pump with an inadequate or excessive amount of oil. The
cost of failures which occur due to incorrect oil levels will not be covered
under warranty.
DO NOT USE A DETERGENT QIL!
NOTE: Unit must be level when in operation
OIL CHART
- ROLAIR Standard 10 WT or 30 WT Should be changed every 200-400 hours after the break-in period
- ROLAIR Semi-synthetic should be changed every 1,000 – 2,000 hours
- ROLAIR Full-synthetic should be changed every 2,000 – 4,000 hours
MAINTENANCE SCHEDULE
Recommendation| Daily| Weekly| Monthly| Quarterly|
Annually
---|---|---|---|---|---
Check Oil Level| X| | | |
Drain Moisture from Tank(s)| X| | | |
Inspect Air Filter(s)| X| | | |
Check for Unusual Noise or Vibration| X| | | |
Inspect Belt Guard| X| | | |
Check for Air or Oil Leaks| X| | | |
Clean Exterior of Air Compressor| | X| | |
Check Condition of Vibration Pads| | X| | |
Tighten/Retorque Bolts| | X| | |
Check Belt Tension| | X| | |
Check Operation of Safety Valve| | X| | |
Change Compressor Oil| | | X| |
Clean/Change Air Filter| | | X| |
Perform Pump Up Time Test| | | X| |
Check Operation of System Controls| | | | X|
Check Air Tanks for Dents/Leaks| | | | X|
Tank Inspection by Certified Inspector| | | | | X
TORQUE CHART (INCH/LB)
Pump Type | Direct Drive |
---|---|
Head Bolts | 96 |
Cylinder Bolts | 120 |
TROUBLESHOOTING
WARNING – Make sure you completely understand all of the safety warnings and operation of each system control component before attempting any maintenance or repair. Always drain the tank pressure completely, make sure the power cord is unplugged, and unit has time to cool before performing any maintenance or service operations.
PROBLEM | CAUSE | SOLUTION |
---|---|---|
Pump is slow to build tank pressure | Excessive leaks in system | Correct air |
leaks
Blown gasket| Replace head gaskets
Broken reed valve| Replace reed valves
Obstructed intake filter| Clean or replace intake element
Leaking regulator| Replace regulator
Excessive oil consumption| Too much oil in crankcase| Drain to proper level
Improper weight of oil| Replace with proper oil
Obstructed crankcase vent| Replace dipstick or oil fill plug/crankcase vent
Dirty/plugged intake filter| Clean/replace intake filter
Worn piston rings| Take unit in for service
Scored cylinder| Take unit in for service
Knocking noise| Internal pump problem| Take unit in for service
Overheating compressor| Poor ventilation| Relocate compressor
Internal pump problem| Take unit in for service
Electric motor dead,
will not even hum| Thermal overload tripped| Locate and push reset button
Reset physically broken| Replace overload/reset
Loose motor leads or electrical connection| Locate and correct loose
electrical connection(s)
Short in power cord| Replace power cord
Motor trips overload/reset button| Motor is starting/stopping excessively|
Install constant speed or dual control kit
Overload is defective/weak| Replace overload
Improper gauge of extension cord| heavier cord
Stripped or poorly tightened motor thru bolts| Retighten or replace stripped
thru bolts
Cracks in end bell or housing| Take unit in for service
Guarantee
Associate Engineering Corporation warrants that all ROLAIR compressors will be
free of defects in material and workmanship for a period of twelve months from
the date of initial retail purchase, or eighteen months from the date of
manufacture, whichever may occur first.
Should any failure to conform to this warranty be reported to the company
within said period, the company shall, upon purchaser shipping the compressor
to our plant transportation prepaid, correct such nonconformity by suitable
repair or, at its option, furnish a replacement part F.0.B. our plant.
Associate Engineering Corporation shall not be liable for any unauthorized
repairs, replacements, adjustments to the compressors, or the costs of labor
performed by the purchaser.
This warranty is expressly in lieu of all other warranties expressed, implied
or statutory (including, but not limited to, warranties of merchantability and
fitness for purpose) and of any other obligations, and/or liabilities on the
part of Associate Engineering Corporation.
Associate Engineering Corporation neither assumes nor authorizes any other
person to assume for it any other obligations or liability in connection with
or with respect to any compressor, Associate Engineering Corporation shall in
no event be liable neither for any consequential, incidental or special
damages nor for the improper selection of any compressor for a particular
application.
Quality
Associate Engineering Corporation is devoted to continual quality control
and thorough research of the products we build. It is our creed to give you,
the user, all of the experience and engineering available in the production of
every piece of equipment we produce.
Our line covers the complete needs of today’s varied air requirements. Rely on
ROLAIR for all the newest and finest features that are available for the
modern compressor.
PARTS LIST FOR FC250090L
Schematic # | Description | Part # | Qty. |
---|---|---|---|
1 | Complete Motor/Pump Assembly | PMP11MK256FC | 1 |
2 | Vibration Dampener | FC199575000 | 4 |
3 | Quick Disconnect | U9001 | 2 |
4 | Check Valve | FC347043000 | 1 |
5 | Disc* | NLA | 1 |
6 | Spring | FC047113002 | 1 |
7 | 0-Ring | FC010024000 | 1 |
8 | Nylon Tubing | FC046001000 | 1.5′ |
9 | Discharge Tube | FC172QC0001 | 1 |
10 | Brass Insert | FC011304000 | 2 |
Brass Compressor Ring | 11,077,000 F | 2 | |
11 | Rubber Plug | FCO20093000 | 2 |
12 | Hair Pin Cotter | FC127QC4018 | 2 |
13 | Drain Valve | U6006 | 1 |
14 | Rubber Foot | FCO20004000 | 2 |
15 | Nipple | FC011080000 | 1 |
16 | Safety Relief Valve | FC047208000 | 1 |
17 | Pressure Switch | FC321099000 | 1 |
18 | Plug | FC011731001 | 2 |
19 | Gauge | FC330063001 | 2 |
20 | Manifold | FC127QCO315 | 1 |
21 | Clamp | FC127QCO290 | 2 |
22 | Tubing | 178A | 1.5′ |
23 | Handle Grip | FCO20306001 | 1 |
24 | Elbow | FC127QC0181 | 1 |
25 | Tank Assembly | FC173079001V88 | 1 |
26 | Plug | FC011008000 | 1 |
27 | Plug | FC011018000 | 1 |
28 | Handle Assembly | FC199000045V51 | 1 |
29 | Lock Nut | FC011117002 | 1 |
30 | Discharge Tee | FC199617000 | 1 |
31 | Ring | FC011117000 | 1 |
32 | Cold Start Valve | FC011158000 | 1 |
33 | Cord with Plug | FC164A08400 | 1 |
34 | Wheel | FCO20296000 | 2 |
35 | Elbow | FC011100013 | 1 |
36 | Nipple | FC199000037 | 1 |
*No longer available, must order complete check valve.
PARTS LIST FOR PMP11MK256FC
Schematic # | Description | Part # | Qty. |
---|---|---|---|
1 | Bolt | FC014002021 | 4 |
2 | Head | FC116022002 | 1 |
3 | Intake Filter Assembly | FC317081000 | 1 |
4 | Gasket | U1100 | 1 |
5 | Valve Plate | U1103 | 2 |
6 | Gasket | U1102 | 1 |
7 | Reed Valve | U1104 | 2 |
8 | Gasket | U1101 | 1 |
9 | Cylinder | FC116QR0001 | 1 |
10 | Bolt | FC014011064 | 2 |
11 | Gasket | FC116091016 | 1 |
12 | Ring Set* | NLA | 1 |
13 | Piston* | NLA | 1 |
14 | Piston Pin | U1115 | 1 |
15 | Snap Ring | U1116 | 2 |
16 | Complete Piston/Connecting Rod Assembly | ||
(Includes Ref# 12, 13, 14, 15, & 17) | U1105 | 1 | |
17 | Connecting Rod | U1106 | 1 |
18 | Capacitor | U1107 | 1 |
19 | Capacitor Cover | FC116034013 | 1 |
20 | Dipstick | U1110 | 1 |
21 | Screw | FC014013021 | 4 |
22 | Drain Plug | FC014013024 | 1 |
23 | Shroud | FC116117030 | 1 |
24 | Crankcase Cover | FC116091002 | 1 |
25 | 0-Ring | FC010072000 | 1 |
26 | Fan | U1109 | 1 |
27 | Diaphragm | FC116091011 | 1 |
28 | Motor Housing | FC116091001 | 1 |
29 | End Bell | U1108 | 1 |
30 | Bearing | FCO33118000 | 1 |
31 | Manual Reset Button | FC008331000 | 1 |
32 | Crankshaft | FC116022011 | 1 |
33 | Bearing | U1114 | 1 |
34 | Seal | FC010029000 | 1 |
35 | Rotor | FC134102000 | 1 |
36 | Stator | FC416GH3652 | 1 |
37 | Gasket Set | FC216093003 | 1 |
38 | Screw | FC014006121 | 2 |
39 | Bolt | FC116011038 | 2 |
Valve Kit (Includes Ref# 4,6,7,8) | VKMK246 | 1 |
606 South Lake Street > P.0. Box 346 > Hustisford,
W1 53034-0346 > 920,349.3281
fax 920.349.8861
www.rolair.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>