AXA 15kVA-12KW 380V Three Phase Voltage Stabilizer Instruction Manual
- June 12, 2024
- AXA
Table of Contents
AXA 15kVA-12KW 380V Three Phase Voltage Stabilizer
SAFETY INSTRUCTIONS
- Make sure that the input voltage is three phase and coalition is correct. The regulator can output 380v(line-to-line voltage) or 230V (line-to-earth), make sure that the output coalition is correct.
- Be sure to connect that ground terminal to the ground for your safe.
- Do not drop any foreign material (like clips, nails, etc.) into the voltage regulator.
- In emergencies {damage to the cabinet or to the connections, splashing of liquid, drop of any foreign material into the voltage regulator), please switch it off, disconnect the wiring connection from the mains power and from the loads, then contact the authorized dealer.
- In the event of sudden temperature changes such as from cold to the normal working temperature, mist can form inside the voltage regulator. The voltage regulator must be dry before being switched on. Due to this reason, wait for at least 2 hours before switching it on.
- The voltage regulator van only be repaired by the authorized technical person. Any attempt to open and to repair it by the user on his own could prove to be dangerous. Placing magnetic storage media on top of the regulator may result in data corruption
WHEN INPUT COMES FROM GENERATOR
The capacity of the generator must be bigger than the rated capacity of the voltage regulator, otherwise the generator and voltage regulator can’t work properly. The output frequency of the generator must be within 45-65Hz. And the generator should has sine wave output, otherwise the regulator can’t work properly.
Front panel
Model: 9KVA~30KVA
- Current indicator-show input current of A phase, B phase and C phase
- Work indicator-show the work status of A phase, B phase and C phase
- Delay button-press to select long delay 180s and short delay 6s
- Door lock-press to unfold the door handle
- Line voltage selector-shift to show AB, BC and AC line voltage
Front panel
Model: 40KVA~100KVA
Wire connecting plate
Technology Parameter
Loading Capability Diagram
Caution:
-
Avoid overloading
Do not use the regulator beyond its maximum output power. -
When connected to any appliance with built-in motor compressor, the starting power(transient power) is generally several time of the appliance’s listed power rating. Make sure that the total starting power capacity of all connected appliance does not exceed the listed maximum output power of the regulator. Make sure that the regulator is of the same output voltage and frequency as the appliance’s it connected.
-
Make sure that the voltage of electrical source is within the listed range of the input voltage of the regulator
-
Always place the regulator in an environment that is:
- Well ventilated.
- Not exposed to direct sunlight or heat source.
- Out of reach from children.
- Away from water moisture oil or grease.
- Away from any flammable substance.
- Secure and no risk of falling.
-
Though the voltage regulator is designed and manufactured according to strict safety standards, but it’s not to be applied to any to any application which may cause any dangerous damage to human safety or human life, include but not limited to the following cases.
- Traffic system
- Medical equipment
- Nuclear system or power system
- Aviation and aerospace
- Other special applications
DISPOSAL
- Waste electrical and electronic equipment are a special waste category, collection, storage, transport, treatment and recycling are important because they can avoid environmental pollution and are harmful to health. Submitting waste electrical and electronic equipment to special collection centers makes the waste to be recycled properly and protecting the environment.
- Do not forget! Each electric appliance that arrives at the landfill, the field, pollutes the environment!