InfiRay PT6 Network Thermal Camera User Guide

June 12, 2024
InfiRay

Dual-spectrum PT6 Network
Thermal Camera
Quick Start Guide
V1.0.2
Dual-spectrum PT6 Network Thermal Camera Quick Start Guide

Open-package Inspection

1.1 Inspection Procedures
Please check whether there is any obvious damage on the device appearance after receiving the camera. The protective materials of the product package can withstand most accidental impacts during transportation.
Then open the outer carton to check whether the accessories delivered with the product are complete. See Table 1-1 for detailed information.
1.2 Accessories
Please confirm whether the items are consistent with the list when unpacking the outer box. For details, see the following table. Please refer to  the product for actual configuration. If any parts are missing, please contactthe dealer in time.
Table 1-1 Accessories List

Accessories QTY Remarks
Shield(thermal) 1
Shield(visible) 1
Sunshield 2
PTZ 1
Flying rings 2
M6*25 screw (with flat washer and spring washer) 16 The protective cover is

connected withL-shaped bracket
H5 hex keys| 1| with M6 screw
M416 screw(with sealing fin)| 10| fix the cover plate
Cover plate| 2|
M4
20 thread-off proof screws(with flat gasket, spring gasket, sealing fin, lifting column)| 12| The protective cover is connected with
the sunshield.
Binding post| 1|
Waterproof cover of the network cable| 1|
Power Supply| 1|
Quick Operation Manual| 1|

Product Introduction

2.1 Cable Instructions
Connect the PTZ to the host communication interface by input port cable, and lock it tightly. Connect cables for the output port of the PTZ according to the labels (the actual cables shall prevail).
Instructions

  • The following connections must be performed by qualified professional technicians or system installers under conditions that meet local regulations.
  • At the same time, it is suggested that the cable connectors should be  protected by a tape, in order to avoid short circuit caused by waterinflow. Otherwise, it will affect the normal use of the product.

InfiRay PT6 Network Thermal Camera

P1Power DC48V Input| Red DC48V+
Black DC48V-| P5 Video| BNC
---|---|---|---
P2 GND| GND| P6 Alarm Output| Yellow Alarm Com1 Green Alarm Out1
Blue Alarm Com2 Red Alarm Out2
P3 Network| RJ45| P7 Alarm Input| Black Alarm GND Red Alarm In7
Yellow Alarm In6 Orange Alarm In5
Blue Alarm In4 Purple Alarm In3
Green Alarm In2 Gray Alarm In1
P4 RS485| Green RS485+
Yellow RS485-| P8 Video Output
P9 Video Input| Green Video Output
Red Video Input

2.2 Camera Introduction

InfiRay PT6 Network Thermal Camera - Camera

2.3 Camera DimensionsInfiRay PT6 Network Thermal Camera - Camera
Dimensions

Camera Installation

3.1 Lightning Protection Instructions
This product adopts plate lightning protection technology, which can effectively prevent damage to equipment caused by instantaneous lightning strikes and surges. However, when the product is installed at a high place, it is necessary to add external lightning protection device.

  • Specifications of lightning arrester: Rated voltage DC48V and recommended nominal discharge current at least 10KA.
  • Signal transmission lines must be kept at least 50m away from high-voltage equipment or high-voltage cables.
  • Outdoor wiring should be routed under the eaves as far as possible.
  • For open areas, the steel pipe must be buried for wiring, and the steel pipe must be grounded at a single point. Overhead wiring is strictly prohibited.
  • For outdoors installation, take necessary protective measures and add power surge protectors according to the actual situation to ensure electrical safety.
  • For application in areas with strong thunderstorms or high induced voltages (such as high-voltage substations), additional measures such as installing high-power lightning protection equipment and installing lightning rods must be taken.
  • The lightning protection and grounding of outdoor devices or cables must be designed according to the lightning protection requirements of buildings, and meet the requirements of relevant national standards and industry standards.
  • The system must be grounded equipotentially. The grounding device must meet the requirements of anti-interference and electrical safety, and must not be short-circuited or mixed with the neutral line of the strong

InfiRay PT6 Network Thermal Camera - connect

3.2 Waterproof Instructions
Before waterproofing, be sure to connect all necessary cables and cut the copper wires off at the unused ends.
Please use self-adhesive waterproof tape (some devices come with it, if not, you need to buy it by yourself) for waterproof treatment
The network cable needs to be protected by a waterproof kit. If the power cable is not used, please waterproof it separately, and the video output cable does not need to be treated.

  1. Wrap the cable joint with electrical tape (purchased by yourself).InfiRay PT6 Network Thermal Camera - electrical

  2. Waterproof the cable with self-adhesive waterproof tape
    (1) Stretch both ends of the self-adhesive waterproof tape until it is tight.
    (2) Wrap the stretched tape tightly at the joint or end of the cable. Please keep the waterproof tape in a tight state during the wrapping process.
    (3) Press the waterproof tape on both sides of the cable to achieve insulation seal.InfiRay PT6 Network Thermal Camera - cable

  3. Place the attached waterproof kit on the network cable in turn as shown in the picture.InfiRay PT6 Network Thermal Camera - network cable

  4. (Optional) Store the waterproof cable in a waterproof junction box (purchased by yourself).

3.3 PTZ Protocol and Address
The default protocol of PTZ: visible light is PELCO-D 9600, address is 001; infrared is PELCO-D 9600, and address is 011.
3.4 PT Installation
Installation steps:
Step 1 Place the shield on the brackets on both sides of PTZ according to the indication labels.InfiRay PT6 Network Thermal Camera - PTZ
according

Step 2 Fix the shield on the PTZ.InfiRay PT6 Network Thermal Camera -
Diagram

Note: The wire covering board of thermal part should be fixed after the coaxial adjustment of the visible image and the thermal image stated in 4.3.
Step 3 Fasten the sunshade to the hood.InfiRay PT6 Network Thermal Camera -
visible

Step 4 Connect the cables of PTZ. Please refer to 2.1 Cable Instructions for details.

Debugging Instructions

After completing the installation, check that the line connection is correct, and then carry out the power-on test. Every time, the entire system will conduct a self-inspection to test whether the basic functions are normal. If the self-inspection is successful, the equipment will stay at a fixed position.
System self-test track: rotate left and right, up and down, and detect the zoom, focus and thermal imaging of the lens at the same time. Stay at the last power-off position of the PTZ. Only after the self-inspection is completed, can other operations be carried out on the equipment.
4.1 Preparations

  1. The default IP address of the device: 192.168.1.108(visible), 192.168.1.109(thermal).
  2.  The subnet mask is 255.255.255.0, and the IP address of the PT can be modified. If you change the device address to 192.168.1.194, change your computer’s IP address to the same network segment with the network video server, and the same subnet mask. Such as 192.168.1.120;
  3. Support browsers such as IE/360.

4.2 Login System

  1. Enter the IP address of the PTZ in the address bar of IE browser to log in, and the login page is as shown below (Install plugin for the first login).
  2. Enter the user name: admin (defaulted, administrator user).
  3. Enter the password: admin (defaulted, administrator password).
  4. Click Login icon to enter the preview screen of the video server. As shown below:InfiRay PT6 Network Thermal Camera - screen

4.3 Coaxial Adjustment of Visible Image and Thermal Image

  1. Preview visible light image and thermal image, and overlay the image with the crosshair in the center of the screen. InfiRay PT6 Network Thermal Camera - Coaxial

  2. Zoom visible light and thermal image to the maximum.

  3. The reticle of visible light is aimed at the target more than 2Km away.

  4. The vertical coaxial direction has been preset in the factory.

  5. Adjust the horizontal direction: loosen the screws of the thermal imaging shield, and turn the shield to align the cross with that of visible light. E.G.
    Visible imagesInfiRay PT6 Network Thermal Camera - Thermal
imagesInfiRay PT6 Network Thermal Camera -
imaging

  6. Lock the thermal imaging shield.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals