AN200, AN300 Electric Fencer
Instruction Manual 85538B – 06/2021
AN200, AN300 Electric Fencer
intellshock AN200……………………….. Type 10957intellishock AN300…………………….. Type 10958
Operating manual of the intellishock AN200_AN300
**** In association with the installation and safety instructions for the
electric fencers
General Safety Instructions
Switch off the pasture fencer before coming into contact with it!
Operating manual information
The operating manual has some important instructions on handling the
energizer. All technical details in the manual have been prepared and compiled
with the greatest possible care. Even so, errors cannot be excluded. We wish
to point out that we cannot assume any guarantee, legal responsibility or any
liability for consequences attributable to possible lack of details. We would,
at all times, welcome any notifi cation of possible errors. Safe working
depends on the indicated safety and handling instructions being adhered to.
Also to be adhered to are those local accident prevention provisions which are
in force where the energizer is used as well as the general safety
requirements.
The operating manual is to be studied carefully before any work begins!
As an integral part of the overall product it is to be securely kept right
next to the energizer and for ease of consultation by the personnel.
Do hand over this manual should this product be sold or passed on to another
party. For a better understanding of what is involved, some of the diagrams in
this manual may not be true-to-scale and may deviate slightly from the actual
constructional design.
Description and Construction of the Product
The energizer transmits voltage pulses to a connected pasture fence.
Caution! Only the optional additional parts prescribed by the
manufacturer are to be used.
Installation
Installation:
The energizer can either be mounted on a wall or on a stable post. The
earthing rod (longitudinal rod) must be driven as deeply as possible into the
ground at a moist location and connected by a corrosion-resistant wire to the
earthing terminal ( **) of the energizer.
Connect the fence cable to the terminal with the lightning symbols . The
energizer is only protected against moisture if it is properly installed.
Shield the energizer from direct solar irradiation. Do not operate the
energizer when it lies on the ground. Set the energizer up in a location where
there is no fire hazard.
Earthing:
Good earthing of the fence is extremely important for trouble-free operation
and optimum performance of the energizer; therefore it should be earthed at a
preferably moist and overgrown location.
If the ground is dry and the fence is long, an additional earth conductor with
intermediate earths (every 50 m) should be installed along the fence.
Installation with a 12V rechargeable battery:
Connect the 12V rechargeable battery (red + / black -), ensure clean pole
terminals and correct polarity. The device will not start if the polarity is
reversed.
CAUTION!
Only use rechargeable 12 V batteries; only charge rechargeable batteries with
ventilation in well-ventilated rooms. Disconnect the rechargeable battery from
the energizer during the charging process.
The rechargeable battery should be recharged before and after every use as
well as during longer periods of storage (every 2 months) and disconnected
from the energizer.
The energizer has an AUTO-ON function which ensures that as soon as power is
connected the energizer starts to operate.
Installation with a 230V/110V mains adapter:
Connect the mains adapter with the energizer, as described in Fig. 3, via the
mains connection .
CAUTION!**
The energizer has an AUTO-ON function. As such, the energizer starts following
connection to the mains network.
Commissioning
Commissioning – Power supply units:
Device starts automatically once it is connected to the power supply After 1
second, you will hear a rhythmic even ticking of the pulses; the device is in
operation.
The energizer transmits pulses to the fence and the LED display lights up. The
fact of the status LEDs not lighting up points to a defect in the power supply
Checking the earthing (10958):
Provoke a short-circuit by driving a metal rod into the ground against the
pasture fence wire (not plastic) about 50 m away from the pasture fencer. The
pasture fencer should now result in the lighting up of only a maximum 1 LED
(moist ground) or of a maximum 2 LEDs (dry ground) (Fig. 2 LED 9 and 8). If
this is not the case, then raise the number and / or length of the earthing
posts.
Energizer Operating Description
Rechargeable battery indicator:
The rechargeable battery indicator (Fig. 2 LED 2) provides information about
the rechargeable battery or battery voltage. The solar display lights up
constantly in green when the solar panel charging voltage is greater than the
voltage of the rechargeable battery/battery. Whilst the solar panel charges
the 12V rechargeable battery, it does not charge the 9 volt battery.
Power economiser:
A fi tted power economiser matches power consumption to the state of the fence.
This means less current consumption with well insulated fences and a greater
current consumption with poorly insulated fences (leakages due to plant
growth, etc.).
Maintenance
Table 13 (12V rechargeable battery) The rechargeable battery must be
recharged at the latest when discharged down to 20% (only 80% charge capacity
left) to prevent a fl at battery. The rechargeable battery indicator (LED2)
lights up:
Do note that temperature and measurement deviation may cause these fi gures to
vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no
solar power supplied – cover panel )
Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
- Switch off energizer
- Disconnect entire energy supply from the energizer.
- Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compatible manner.
Then properly clean sub-assemblies and parts and disassemble them in taking
account of the local industrial safety & environmental protection provisions
in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched
off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
Faults and Repairs
WARNING!
Repairs may only be carried out by qualifi ed persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
Table 14
Faults | Display | Corrective action |
---|---|---|
Rechargeable battery under40% capacity | LED2 fl ashes alternately red/green |
Charge the battery
Rechargeable battery under 20% capacity| LED2 fl ashes red| Charge the battery
Technical data
CEE: max. fence line length
Subject to technical alterations!
Fig. 1
Spare parts Fig. 3
Installation and connection
For 230V operation the energizer should be and the adapter must be installed in a room protected from moisture.