Mitsubishi Electric Trane HVAC PUZ-A24NHA7 P-Series Air Conditioner Outdoor Unit User Manual
- June 12, 2024
- Mitsubishi Electric Trane HVAC
Table of Contents
- Mitsubishi Electric Trane HVAC PUZ-A24NHA7 P-Series Air Conditioner
- P-Series Model Reference Guide
- Product Overview
- Backup Rotation Function
- Continuous Operation
- P-Series Heat Pump Sound Levels
- Wide Operation Range
- Flexible Installation
- P-Series Heat Pump Piping Lengths and Heights
- INFO
- Cooling Only
- Continuous Operation
- Heat Pump
- Flexible Installation
- Documents / Resources
Mitsubishi Electric Trane HVAC PUZ-A24NHA7 P-Series Air Conditioner
Outdoor Unit
P-Series Model Reference Guide
Family| Type| Cooling/Heat Pump| Model Version| Compressor Voltage| Capacity
(Nominal) BTU/H (X 1,000)
---|---|---|---|---|---
P = Professional| K = Wall-mounted Indoor Unit
C = Ceiling-suspended Indoor Unit
L = Ceiling Cassette Indoor Unit
E = Horizontal-ducted Indoor Unit
V = Multi-position Air Handler
U = Single-zone Outdoor Unit| Y = Cooling Only (INVERTER-driven)
Z = Heat Pump (INVERTER-driven)
A = Both Heating And Cooling| BS = Seacoast Protection| N = 208/230V| PUZ-
A12NKA7
PUZ-A18NKA7
PUZ-A24NHA7
PUZ-A30NHA7
PUZ-A36NKA7
PUZ-A42NKA7
Product Overview
Cooling Only PUY Model offers high reliability and performance in low ambient conditions. It has a low ambient cooling operation range. The piping length varies for different models. New model (PUY-ANKA/NHA7) has a quick auto restart feature after power failure, with the unit starting back up in the same operation mode it ran when the power failure occurred. Previous model (PUY-ANKA/NHA6) does not have the quick auto restart feature.
Backup Rotation Function
The two units operate alternately to maintain equal runtimes and equivalent wear, extending their life. In this configuration, if one unit experiences issues, the other unit continues to operate. This function can only be used with PAR-40MAAU controller. New model (PUY-A**NKA/NHA7) has an auto restart time of 60 seconds after a power failure.
Continuous Operation
A control algorithm allows for stable continuous operation to meet cooling requirements all year round. The unit will quickly restart with the same operation mode as before the power failure.
P-Series Heat Pump Sound Levels
PUZ Series outdoor unit* | Sound Level (dB(A)) |
---|---|
PUZ-A12/18 cooling mode | 30 dB(A) |
Library interior | 40 dB(A) |
44 dB(A) | |
40 dB(A) | |
50 dB(A) | |
60 dB(A) | |
65-75 dB(A) | |
Quiet passenger car interior (40km/h) | 80 dB(A) |
Outdoor unit | 80 dB(A) |
Subway car interior | 60 dB(A) |
70 dB(A) | |
80 dB(A) | |
90 dB(A) |
Wide Operation Range
P-Series heat pumps offer a wide temperature operation range, easily fitting many climate design conditions.
Flexible Installation
Long piping lengths enable system design flexibility for applications such as apartment buildings, churches, or strip malls.
Piping Length (ft) | Height (ft) | HSPF | SEER |
---|---|---|---|
PUZ-A12NKA7 | 100 | 27.0 | 12.8 |
PUZ-A18NKA7 | 100 | 24.6 | 24.2 |
PUZ-A24NHA7 | 165 | 22.8 | 21.8 |
PUZ-A30NHA7 | 165 | 21.0 | 13.0 |
PUZ-A36NKA7 | 165 | 11.0 | 11.2 |
PUZ-A42NKA7 | 165 | 10.4 | 9.3 |
P-Series Heat Pump Piping Lengths and Heights
Piping Length (ft) | Height (ft) |
---|---|
PLA-A12EA7 | 100 |
PLA-A18EA7 | 100 |
PLA-A24EA7 | 100 |
PLA-A30EA7 | 100 |
PLA-A36EA7 | 165 |
PLA-A42EA7 | 165 |
INFO
- Designed for light commercial installations. Ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms
- Hyper-Heating INVERTER® (H2i®) outdoor units can provide superior heating performance at lower ambient temperatures
- Long lineset lengths
- Outside air intake on PLA, PCA, PEAD and PVA models
- P-Series ducted units have higher static than most M-Series, allowing for design flexibility
Cooling Only
PUY Model
High Reliability and Performance in Low Ambient Conditions The PUY Model
cooling only unit provides cooling all year round, even in cold climate low
ambient conditions. By controlling the fan speed, the PUY can offer stable
cooling operation down to -40° F. Optional Air Protection Guide/Wind Baffle is
needed when ambient temperature is under 23° F.
Low Ambient Cooling Operation Range
Quick Auto Restart After Power Failure
In case of power failures, auto restart time shortens from 180 seconds to 60
seconds. The unit starts back up in the same operation mode it ran when the
power failure occurred.
Piping Length
Piping | |
---|---|
Length (ft) | Height (ft) |
PUZ-A12NKA7 PUZ-A18NKA7 PUZ-A24NHA7 PUZ-A30NHA7 PUZ-A36NKA7
PUZ- A42NKA7
| 100| 100
100| 100
165| 100
165| 100
165| 100
165| 100
Backup Rotation Function
The two units operate alternately to maintain equal runtimes and equivalent
wear, extending their life. In this configuration, if one unit experiences
issues, the other unit continues to operate. Can only be used with PAR-40MAAU
controller
Continuous Operation
A control algorithm allows for stable continuous operation to meet cooling requirements all year round. The unit will quickly restart with the same operation mode as before the power failure.
Heat Pump
Wide Operation Range
P-Series heat pumps offer a wide temperature operation range, easily fitting
many climate design conditions.
- In case that the air protection guide wind baffle is installed. (In case the wind baffle is not installed, the minimum temperature will be 23° F (–5° C) DB)
- A24/30/36/42
Flexible Installation
Long Piping Length
Long piping lengths enable system design flexibility for applications such as
apartment buildings, churches, or strip malls.
Piping | |
---|---|
Length (ft) | Height (ft) |
PUZ-A12NKA7 PUZ-A18NKA7 PUZ-A24NHA7 PUZ-A30NHA7 PUZ-A36NKA7
PUZ- A42NKA7
| 100| 100
100| 100
165| 100
165| 100
165| 100
165| 100
Energy Efficiency
Documents / Resources
|
Mitsubishi Electric Trane HVAC PUZ-A24NHA7 P-Series Air Conditioner Outdoor
Unit
[pdf] User Manual
PUZ-A24NHA7, PUZ-A30NHA7, PUZ-A24NHA7 P-Series Air Conditioner Outdoor Unit,
P-Series Air Conditioner Outdoor Unit, Conditioner Outdoor Unit, Outdoor Unit
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>