J-SCALE JZ-115 Pocket Scale User Manual
- June 12, 2024
- J-SCALE
Table of Contents
J-SCALE JZ-115 Pocket Scale
Product Information
The JZ-115, JZ-230, and JZ-560 are precision digital scales designed for
accurate weight measurement. They have different capacities and precision
levels as mentioned below:
Model | Precision | Capacity |
---|---|---|
JZ-115 | 0.01g / 0.001oz / 0.001ozt / 0.01dwt | 115g / 4.06oz / 3.7ozt / 73.9dwt |
JZ-230 | 0.1g / 0.01oz / 0.01ozt / 0.1dwt | 230g / 8.12oz / 7.4ozt / 147.9dwt |
JZ-560 | 0.1g / 0.01oz / 0.01ozt / 0.1dwt | 560g / 19.75oz / 18ozt / 360.1dwt |
Product Usage Instructions
Operation
- Place the scale on a horizontal flat surface.
- Press the [ ] key to turn on the scale. Hold [ ] for 3 seconds to turn off.
- Wait until 0 is displayed.
- Place the object(s) on the weighing platform.
- Press the [ M ] key to toggle the weighing units.
Tare
- Turn on the scale as described above.
- Place the tare item on the platform.
- Press and wait until 0 is displayed.
- Add the net-weight item.
- Press again to return the scale to zero.
Calibration
JZ-115 Calibration
- Ensure the scale is off and place it on a stable surface.
- Press and hold [ M ] and buttons. Release when the display shows “CAL” and the AD value (a series of random numbers).
- Press again. The LCD display will flash the required calibration weight.
- Place the required calibration weight on the tray and wait for 3 seconds. The display will show “PASS”.
- Calibration is complete. Remove the weight and continue.
JZ-230 Calibration
- Ensure the scale is off and place it on a stable surface.
- Press and hold the [ M ] and [ ] buttons. Release when the display shows the AD value (a series of random numbers).
- Press [ ] again. The LCD display will show “CAL” and the required calibration weight.
- Place the required calibration weight on the tray and press The display will show “PASS”.
- Calibration is complete. Remove the weight and continue.
JZ-560 Calibration
- Ensure the scale is off and place it on a stable surface.
- Press and hold [ M ] andbuttons. Release when the display shows the AD value (a series of random numbers).
- Press again. The LCD display will show “CAL” and the required calibration weight.
- Place the required calibration weight on the tray and press The display will show “PASS”.
- Calibration is complete. Remove the weight and continue.
Thank you for purchasing the J-SCALE® JZ pocket scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service.
Precision | Capacity |
---|---|
0.01g | 115g |
0.001oz | 4.06oz |
0.001ozt | 3.7ozt |
0.01dwt | 73.9dwt |
0.1g | 230g |
--- | --- |
0.01oz | 8.12oz |
0.01ozt | 7.4ozt |
0.1dwt | 147.9dwt |
0.1g | 560g |
--- | --- |
0.01oz | 19.75oz |
0.01ozt | 18ozt |
0.1dwt | 360.1dwt |
OPERATION
- Place the scale on a horizontal surface, and press the [ ] key to turn on the scale. Hold [ ] for 3 seconds to turn.
- Wait until “0” is displayed.
- Place the object(s) on the weighing platform.
- Press the [M] key to toggle the weighing units.
TARE
- Turn on the scale as described above.
- Place the “tare item” on the platform.
- Press [ ] and wait until “0” is displayed.
- Add the “net-weight-item”.
- Press [ ] again to return the scale to zero.
CALIBRATION
The JZ-115 requires a 100g weight to calibrate.
- Ensure the scale is placed on a stable surface.
- Press and hold the [M] and [ ] buttons. Release when the display shows “CAL” and the AD value (a series of random numbers).
- Press [ ] again, and the LCD display will ash the required calibration weight.
- Place the required calibration weight on the tray and wait 3 seconds. The display will show “PASS”.
- Calibration is complete. Remove the weight and continue.
The JZ-230 requires a 200g and JZ-560 requires a 500g weight to calibrate.
- Ensure the scale is placed on a stable surface.
- Press and hold the [M] and [ ] buttons. Release when the display shows the AD value (a series of random numbers).
- Press [ ] again, and the LCD display will show “CAL” and then the required calibration weight.
- Place the required calibration weight on the tray and press [ ]. The display will show “PASS”.
- Calibration is complete. Remove the weight and continue.
SPECIFICATIONS
- Tare Range Full Capacity
- Op. Temp 10 to 30 ºC
- Power 2 x AAA
- Scale Dim. 88mm x 60mm x 20mm
- Tray 50mm x 55mm
- Modes g, oz, ozt, dwt
DISPLAY ERROR MESSAGES
- [88888] Overload
- [OUT2] Recalibrate