PIMA DPS743 Wireless 2-Way PIR PET Detector Instruction Manual

June 12, 2024
PIMA

Wireless 2-Way
PIR/PET Detector Installation
Instructions

Model:
DPS743 / DPS786
DPP743 / DPP786

DPS743 Wireless 2-Way PIR PET Detector

PIMA DPS743 Wireless 2 Way PIR PET Detector - FigPIMA DPS743 Wireless 2 Way PIR PET Detector - Fig
1PIMA DPS743 Wireless 2 Way PIR PET Detector - Fig
2

Description

The Wireless DPS/DPP PIR/PET is a stylish wall mounted passive infrared detector.
Features include:

  • Selectable range of up to 10m in PIR ver. or 8m in PET ver.
  • Easy battery replacement

What’s in the box:

  • Wireless DPS/DPP PIR/PET Detector
  • Screws Kit: 1 screw ø2.5×6 mm; 2 screws ø3.5×25 mm
  • Installation Instructions

Installation

Step 1a: Preliminary Considerations
Select the mounting location for best coverage of the area that is to be protected.
Install the device in a location where the detector’s field of view is clear of any static obstacle.
Please note that walking direction must cut across the beam pattern (see Figure 1).
Step 1b: Coverage Patterns (see Figures 2 and 3)
Step 2: Enrolling the Detector into the System
For complete description of the wireless configuration and device enrollments, refer to Programming Guide for the FORCE and VISION Alarm Systems
Enrollment of the detector in the system can be performed manually or automatically via the keypad.
Important Note: Verify that SW1 is set to ON (defines the detector as 2way). See Figure 7.
Auto Enrolling (using RF Communication):

  1. Enter Installer menu, and select :System Configuration > Peripherals > Wireless Peripherals > Enroll and delete > Detectors >Enroll >Auto Enrollment

  2. Insert the batteries and close the bracket

  3. In 3 seconds the detector will send an Enrollment message.
    The serial number should appear on the keypad.

  4. Select Enroll and press .

Manual Enrolling:

  1. Enter Installer menu, and select: System Configuration > Peripherals > Wireless Peripherals > Enroll and delete > Detectors >Enroll >Manual Enrollment
  2. Enter the serial number and press .
  3. Select Enroll and press .

Enrolling through the Force Manager Software:
You can enroll the detector using Force Manager software; For information refer to the Force Manager Manual.
Step 3: Mount the Detector on the Wall Bracket
Mount the detector at a height of 2.4 m. (see Figures 4 to 6).
Detector Configuration
Being 2-way, the detectors parameters can be modified from the keypad or from the Force Manager software according to your needs.

PIR Sensitivity: High/Low
LED: On*/Off

Step 5: Inserting Battery (see Figure 8)
CAUTION!
The detector battery may be supplied with plastic wrapping. If so, remove the plastic wrapping from the battery before installation.
Observing battery polarity.
Insert a battery into the compartment.
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to local regulation.
Step 6: Mount the detector on the bracket (see Figure 9)

Walk Test

The detector automatically enters walk test mode for 10 minutes following tamper closure. Walk through the entire protected area and observe the LEDs to confirm full coverage (see LED Status).
When complete, secure the detector with screw (see Figure 10).
Manually initiate a Walk-Test
In the Installer menu, select Test and Diagnostic > Walk test. Select All or Single zone.
The detector(s) remain in walk test mode until exiting the menu.

LED Status

LED State Description
Red On Alarm
Flashing Low Battery

Technical Specifications

Parameter Description

Current
Consumption:| 10µA standby
Supervision
Time| 1-Way: 15 min.
(868MHz); 65 min.
(433MHz) 2-Way: 15 min.
Battery Type| CR123 3V Lithium Battery
Battery Life| 3 years typical
Low Voltage Threshold| 2.6V
Power Output| 10mW
Operating temperature:| -10°C to 55°C (14°F to 131°F)
Storage temperature:| -20°C to 60°C (-4°F to 140°F)
Humidity
Range| Average relative humidity: 75%
Weight| 100gr.
Dimensions| 102.5 x 40.5mm
Frequency| 433.92MHz, 868.65MHz
Standards| EN50131-2-2 Grade 2,
Environmental Class II,
EN50131-6: Type C PD6662:2017

Ordering Information

Model Frequency P/N
DPS743 (PIR) 433MHz 8841210
DPS786 (PIR) 868MHz 8841211
DPP743(PET) 433MHz 8841212
DPP786(PET) 868MHz 8841213

UKCA and RED Compliance Statement:
Hereby, PIMA declares that this equipment is in compliance with the essential requirements of the UKCA Radio Equipment Regulations 2017 and CE Directive 2014/53/EU.
For the UKCA and CE Declaration of Conformity please refer to our website: www.pima-alarms.com 
Limited Warranty
PIMA Electronic Systems Ltd. does not represent that its product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The User understands that a properly installed and maintained equipment may only reduce the risk of events such as burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such will not occur or that there will be no death, personal damage and/or damage to property as a result.
Read this guide in its entirety before attempting to program or operate your system. Should you misunderstand any part of this guide, please contact the supplier or installer of this system.
Copyright © 2022 PIMA Electronic Systems Ltd. All rights reserved. E&OE
Contacting PIMA
PIMA Electronic Systems Ltd.
www.pima-alarms.com
5, Hatzoref Street, Holon 5885633, Israel
Tel: +972.3.6506414
Fax: +972.3.5500442
Email: support@pima-alarms.com

© PIMA 05/2022 4412986-A
5IN2986-A
Scan for technical documentationhttps://www.pima-alarms.com/wp- content/uploads/dps2.html 

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals