PIMA DPS743 Wireless 2-Way PIR PET Detector Instruction Manual
- June 12, 2024
- PIMA
Table of Contents
Wireless 2-Way
PIR/PET Detector Installation
Instructions
Model:
DPS743 / DPS786
DPP743 / DPP786
DPS743 Wireless 2-Way PIR PET Detector
Description
The Wireless DPS/DPP PIR/PET is a stylish wall mounted passive infrared
detector.
Features include:
- Selectable range of up to 10m in PIR ver. or 8m in PET ver.
- Easy battery replacement
What’s in the box:
- Wireless DPS/DPP PIR/PET Detector
- Screws Kit: 1 screw ø2.5×6 mm; 2 screws ø3.5×25 mm
- Installation Instructions
Installation
Step 1a: Preliminary Considerations
Select the mounting location for best coverage of the area that is to be
protected.
Install the device in a location where the detector’s field of view is clear
of any static obstacle.
Please note that walking direction must cut across the beam pattern (see
Figure 1).
Step 1b: Coverage Patterns (see Figures 2 and 3)
Step 2: Enrolling the Detector into the System
For complete description of the wireless configuration and device enrollments,
refer to Programming Guide for the FORCE and VISION Alarm Systems
Enrollment of the detector in the system can be performed manually or
automatically via the keypad.
Important Note: Verify that SW1 is set to ON (defines the detector as 2way).
See Figure 7.
Auto Enrolling (using RF Communication):
-
Enter Installer menu, and select :System Configuration > Peripherals > Wireless Peripherals > Enroll and delete > Detectors >Enroll >Auto Enrollment
-
Insert the batteries and close the bracket
-
In 3 seconds the detector will send an Enrollment message.
The serial number should appear on the keypad. -
Select Enroll and press .
Manual Enrolling:
- Enter Installer menu, and select: System Configuration > Peripherals > Wireless Peripherals > Enroll and delete > Detectors >Enroll >Manual Enrollment
- Enter the serial number and press .
- Select Enroll and press .
Enrolling through the Force Manager Software:
You can enroll the detector using Force Manager software; For information
refer to the Force Manager Manual.
Step 3: Mount the Detector on the Wall Bracket
Mount the detector at a height of 2.4 m. (see Figures 4 to 6).
Detector Configuration
Being 2-way, the detectors parameters can be modified from the keypad or from
the Force Manager software according to your needs.
PIR Sensitivity: | High/Low |
---|---|
LED: | On*/Off |
Step 5: Inserting Battery (see Figure 8)
CAUTION!
The detector battery may be supplied with plastic wrapping. If so, remove the
plastic wrapping from the battery before installation.
Observing battery polarity.
Insert a battery into the compartment.
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to local regulation.
Step 6: Mount the detector on the bracket (see Figure 9)
Walk Test
The detector automatically enters walk test mode for 10 minutes following
tamper closure. Walk through the entire protected area and observe the LEDs to
confirm full coverage (see LED Status).
When complete, secure the detector with screw (see Figure 10).
Manually initiate a Walk-Test
In the Installer menu, select Test and Diagnostic > Walk test. Select All or
Single zone.
The detector(s) remain in walk test mode until exiting the menu.
LED Status
LED | State | Description |
---|---|---|
Red | On | Alarm |
Flashing | Low Battery |
Technical Specifications
Parameter | Description |
---|
Current
Consumption:| 10µA standby
Supervision
Time| 1-Way: 15 min.
(868MHz); 65 min.
(433MHz) 2-Way: 15 min.
Battery Type| CR123 3V Lithium Battery
Battery Life| 3 years typical
Low Voltage Threshold| 2.6V
Power Output| 10mW
Operating temperature:| -10°C to 55°C (14°F to 131°F)
Storage temperature:| -20°C to 60°C (-4°F to 140°F)
Humidity
Range| Average relative humidity: 75%
Weight| 100gr.
Dimensions| 102.5 x 40.5mm
Frequency| 433.92MHz, 868.65MHz
Standards| EN50131-2-2 Grade 2,
Environmental Class II,
EN50131-6: Type C PD6662:2017
Ordering Information
Model | Frequency | P/N |
---|---|---|
DPS743 (PIR) | 433MHz | 8841210 |
DPS786 (PIR) | 868MHz | 8841211 |
DPP743(PET) | 433MHz | 8841212 |
DPP786(PET) | 868MHz | 8841213 |
UKCA and RED Compliance Statement:
Hereby, PIMA declares that this equipment is in compliance with the essential
requirements of the UKCA Radio Equipment Regulations 2017 and CE Directive
2014/53/EU.
For the UKCA and CE Declaration of Conformity please refer to our website:
www.pima-alarms.com
Limited Warranty
PIMA Electronic Systems Ltd. does not represent that its product may not be
compromised and/or circumvented, or that the Product will prevent any death,
personal and/or bodily injury and/or damage to property resulting from
burglary, robbery, fire or otherwise, or that the Product will in all cases
provide adequate warning or protection. The User understands that a properly
installed and maintained equipment may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a
guarantee that such will not occur or that there will be no death, personal
damage and/or damage to property as a result.
Read this guide in its entirety before attempting to program or operate your
system. Should you misunderstand any part of this guide, please contact the
supplier or installer of this system.
Copyright © 2022 PIMA Electronic Systems Ltd. All rights reserved. E&OE
Contacting PIMA
PIMA Electronic Systems Ltd.
www.pima-alarms.com
5, Hatzoref Street, Holon 5885633, Israel
Tel: +972.3.6506414
Fax: +972.3.5500442
Email: support@pima-alarms.com
© PIMA 05/2022 4412986-A
5IN2986-A
Scan for technical documentationhttps://www.pima-alarms.com/wp-
content/uploads/dps2.html
References
- Alarms.com
- Pima Electronic Systems | Residential & Commercial Security Systems
- Pima Electronic Systems | Residential & Commercial Security Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>