Verkada TD52 Video Intercom Installation Guide

June 12, 2024
Verkada

Install Guide
TD52 Video IntercomVerkada TD52 Video Intercom

TD52 Video Intercom

Document
Document Details
V1.6 (20230816)
(V1.0 first published 20230214)
Firmware
Firmware version can be verified on
Verkada Command command.verkada.com.
Product Models
This install guide pertains to TD52-HW.
UL294 Performance Levels

  • Attack Level: Level I
  • Endurance Level: Level I
  • Line Security Level: Level I
  • Standby Power Level: Level I

CAN/ULC-60839-11-1

  • Environmental Level: Outdoor
  • Grade assignment: Grade I
    Note: Video, audio, and intercom performance were not evaluated by UL. Additionally, PoE+ functionality (extended temperature range) was not evaluated by UL.

Introduction

Technical Specifications

Sensor Resolution 5MP (2688 x 1944)
Lens Type Fixed
Image Sensor 1/2.8” Progressive CMOS
Focal Length 2.12mm
Iris Fixed
Aperture F2.0

Field of View

| Horizontal: 130°
Vertical: 100°
Diagonal: 160°
IR Range| 15m / 50ft in low light
Onboard Storage| 256GB
Audio Streaming| Two-way, full duplex with echo cancellation and noise suppression
Audio Output| 5W speaker ; 90dB SPL at 1m / 3.3ft
Audio Input| 2 omnidirectional digital MEMs microphones
Inputs / Outputs| 2x dry inputs
1x dry relay, 30VDC @ 1A (resistive load) 1x RS-485 port, 12V @ 250mA output
Dimensions| 238mm (L) x 128mm (W) x 44mm (H) 9.4in (L) x 5in(W) x 1.7in (H)
Weight| 1.1kg/2.3lb
Tamper Detection| Yes
Resistance Rating| IK08, IP66
Operating Specs| Power: 11.5W (IEEE 802.3af PoE) ; Extended Temperature Range: 25.5W (IEEE 802.3at PoE) Temperature: -20°C – 50°C / -4°F – 122°F, PoE 802.3af ; -40°C – 50°C / -40°F – 122°F, PoE 802.3at Humidity: 90%
Compliance| FCC Part 15B Class B, ICES-003 Class B, CE, UKCA, KCC, RCM, VCCI, UL/IEC 62368-1, CSA NO22.2 62368-1, UL 294, ULC-60839-11-1 Outdoor
Connectivity| Ethernet: 10/100Mbps RJ-45 cable connector for Network/PoE connection
Included Accessories| T10 screwdriver, mounting hardware kit, grommet punch
Mounting Options| Flush mount plate (included), surface mount box (separate accessory), angle mount box (separate accessory), trim plate (separate accessory), rain hood (separate accessory)

What’s in the box

Verkada TD52 Video Intercom - box

What you’ll need

  • A working internet connection
  • A smartphone or laptop
  • A #2 Phillips head and power drill
  • A level

Connect
Connect the TD52 to your network using the Ethernet port located behind the rear door of the device.
Supports PoE and PoE+. PoE+ required for full functionality, including extended temperature range (down to -40C/-40F) and RS-485 support. Shall be powered by an UL294 and ULC-68039-11 certified PoE Power Supply. Note,
PoE+ ratings were not evaluated by UL.
After connecting the TD52 to network and power, visit: verkada.com/start
For detailed installation instructions, visit: verkada.com/support

Overview

Verkada TD52 Video Intercom - Overview

Status LED Behavior

| Solid Orange
Intercom is on and booting up.
---|---
| Flashing Orange
Intercom is updating firmware.
| Flashing Blue
Intercom is managing doors, but cannot reach the server.
| Solid Blue
Intercom is managing doors and connected to the server.
| Flashing Pink
Identify.

Call Button LED Behavior

| Off
Intercom is unpowered
---|---
| On
Intercom is powered

Feedback LEDs

Normal Behavior

| Cascading White
The call button has been pressed and the intercom is making a call.
---|---
| Solid White
The call has been connected and audio/video is being shared.
| Solid Green
The door has been unlocked.

Setup Behavior

| Intercom is connected to power and booted
---|---
| Intercom has an IP address
| Intercom has connected to Verkade’s server
| Intercom has commissioned and has an authentication token
| Intercom can connect to Twilio’s server and register with SIP
| Intercom has all required ports enabled
| Intercom has a valid receiver and is ready to make a call

Connect
To add the TD52 to your Verkade
Command account, go to: command.verkada.com/add- device Enter the serial number printed on the back of the device, the packaging, or  the order number.
If you would like to update and configure TD52 before mounting it, connect the device to your network using the Ethernet port located in the cable bay on the back of the device.Verkada TD52 Video Intercom -
Verkada

Mounting 1/7
The flush mount plate has holes configured for the following mounting conditions:
A/B Legacy intercom back box Direct wall mounting
C 4-gang junction box mounting
Use the corresponding holes to mount to an existing intercom back box (A/B ) or 4-gang junction box (C).

Direct wall mounting
To mount directly to a wall, use the mount plate as a template to mark mounting holes (B) and the center cutout.
Use the marks to drill pilot holes for the mount plate. For direct mounting, drill 3mm pilot holes. When using wall anchors, drill 6mm pilot holes. Verkada TD52 Video Intercom - wall mountingUse the supplied screws to install the mount plate onto the wall. Ensure that the labels (A, B, C) on the mount plate are facing away from the wall.
Please note: The supplied screws are intended to cover most possible install cases. Be sure to use the best screws for your specific job.

Mounting 2/7
Route the building-side cable through the hole in the center of the mount plate.Verkada TD52 Video Intercom - wall mounting 1

On the rear of the device, loosen the four T10 Torn Security screws on the cable bay door to access the ethernet and I/O ports.

Mounting 3/7
Attach grommet punch to the RJ-45 cable.

Insert the RJ-45 ethernet cable through the right grommet using the included grommet punch and pass through the cable bay door.

Remove the grommet punch and Insert the RJ-45 ethernet cable into the PoE port.

Mounting 4/7
If the installation requires the use of the I/O terminal block, insert I/O wires through the left grommet and pass through the cable bay door. Remove the I/O terminal block with a flat head screwdriver or the end of the grommet punch tool for easier installation.Verkada TD52 Video Intercom - wall
mounting7

Attach I/O wires according to the pins below.

Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10
NO COM NC GND B A 12V GND IN 1 IN 2
Output RS-485 Input

Mounting 5/7
Plug in the RJ-45 and the I/O terminal block. Verkada TD52 Video Intercom -
wall mounting8

Return the grommets to the cable bay door. Make sure the grommet is installed in the right direction for proper sealing.

Please note: The tail of the grommet should be facing away from the device after installation for proper sealing.Verkada TD52 Video Intercom - wall
mounting10

Secure the cable bay doors by tightening the four T10 Torx Security screws at each corner.

Mounting 6/7
On the bottom edge of the device, loosen the two T10 Torx Security screws and remove the faceplate.

Attach the device to the mount plate to the wall using the four provided M4 machine screws.Verkada TD52 Video Intercom - wall
mounting11

Mounting 7/7
Reattach the faceplate by engaging the hooks at the top. Swing the faceplate down into position. Verkada TD52 Video Intercom -
faceplate

Tighten the two T10 Torx Security screws on the bottom edge of the device.

Verkada TD52 Video Intercom - Torx Security.

Wiring Instruction

Reader
The TD52 is rated to power Verkade readers at 12V and 250mA via the (+) and (-) connection. It is recommended that the drain wire be connected to earth ground at the reader side. Note: 12V power should not to be used to power other peripheral devices, as it has latch-off current limiting. Verkada TD52
Video Intercom - Reader

Inputs
The TD52 has two general purpose dry inputs. Devices commonly connected to these dry contacts include Door Position Indicator (DPI), Request to Exit (REX), and external call triggers. Both inputs are expected to be NORMALLY OPEN (NO). For each input, one wire should be connected to the IN pin, and the other to the GND pin. All associated events will be logged in Command.
Note: When configuring the TD52 as an single door controller, the DPI should be connected to IN 1, while the REX should be connected to IN 2.Verkada TD52 Video Intercom - Inputs

Output
The TD52 has one dry form C relay output, which can be configured as an access controller by connecting an access power controller to the output terminal as detailed below. The output relay can also be used as a general purpose output. For fail safe locks, + should be connected to NC to be locked by default. For fail secure locks, + should be connected to NO to be locked by default. Verkada TD52 Video Intercom - Output

Note: To maintain UL294 compliance all devices connected to TD52 devices connect to TD-52HW should be UL 294 and ULC 60839-11-1 Listed

Appendix

TD52 Compliance
FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a  residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there  is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is  encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help

IC Statement

This device complies with ISED’s license-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Appendix
Support
Thank you for purchasing this Verkade product. If for any reason you’re experiencing issues or need assistance, please contact our 24/7 Technical Support Team immediately.
Sincerely,
The Verkade Team verkada.com/support

Verkade Inc. 405 E 4th Ave, San Mateo, CA 94401
sales@verkada.com
All specifications are subject to change without notice
Copyright © 2022 Verkade Inc. All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals