Sunco DL_SL6-HO-2750K 6 Inch High Lumen Selectable Slim Downlight User Manual
- June 12, 2024
- SUNCO
Table of Contents
Sunco DL_SL6-HO-2750K 6 Inch High Lumen Selectable Slim Downlight
Product Information
- Product Name: 6 High Lumen Selectable Slim Downlight
- SKU: DL_SL6-HO-2750K
- Manufacturer: Sunco Lighting
- Contact Information: support@sunco.com / 844-334-9938
American Company
What’s in the Box?
- Slim Downlight Fixture x1
- Junction Box x1
- Installation Template x1
- Wire Nuts x2
- Tape
- Hole Saw 1
- Ladder
- Wire Strippers
Product Usage Instructions
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
-
This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions: -
This device may not cause harmful interference.
-
This device must accept any interference that may cause
undesired operation.
Please review all instructions carefully prior to
installation.
Quickstart Guide
- Use the provided template to cut a hole in the ceiling.
- Connect the supply and junction wires.
- Attach the fixture to the junction box.
- Insert the fixture into the ceiling.
Installation Guide
Note: The following steps assume that the circuit breaker is turned off before installation.
- Step 1
- Cut out a 6.33-inch hole on the Installation Template.
- Tape the template onto the ceiling in the desired location.
- Cut the ceiling hole using the Installation Template as a guide.
- Step 2 Open the junction box and remove the appropriate knockout.
- Step 3
- Connect the supply and junction wires using wire nuts:
* Black to Black (Live)
* White to White (Neutral)
2. Tuck the connected wires inside the junction box and close the cover.
- Step 4
- Slide the CCT Selection Switch to choose from five color temperatures:
* 5000K
* 4000K
* 3500K
* 3000K
* 2700K
2. Insert the junction box through the ceiling hole.
3. a. For New Construction Applications: Secure the fixture to studs, joists, or similar fixed structural units.
4. b. For Remodel Applications: No need to secure the fixture to studs, joists, or similar fixed structural units.
- Step 5
- Attach the fixture to the junction box using the provided connector (refer to image 1).
- Tighten the connector by hand (refer to image 2).
- Step 6
- Push up the spring clips and insert the fixture into the ceiling.
- Turn on the circuit breaker and test the light.
Product Details
Recommended Dimmers
- Lutron P-PKG1WB-WH
- Lutron MACL-153M-WH
- Lutron PD-6WCL-WH
- Lutron AYCL-153P-WH
- Lutron DVCL-153P-WH
- Leviton D26HD-2RW
- Kasa Smart HS220
- Kasa Smart HS220P3
Specifications
- Voltage
- Wattage
- Wattage Equivalency
- Beam Angle
- Weight
- Housing Material
- Dimmable
- Model
- Average Lifetime
- Lumens
- Moisture Rating
- CRI Usage
- IC Rated
- Warranty
Common Troubleshooting
If you encounter any issues with your product, please refer to the following troubleshooting guide:
- Light isn’t turning on:
- Double-check if the fixture is properly connected and the circuit breaker hasn’t been tripped.
- Light isn’t bright enough:
- Check if the dimming function is properly adjusted.
- Light not dimming to lowest setting:
- Ensure that the dimmer switch is compatible with the light fixture.
- Light not dimming smoothly:
- Verify compatibility between the light fixture and the dimmer switch.
- Light is flickering:
- Check if the light flickers when turned on or when other lights on the same circuit are on.
- Ensure that the dimmer switch is compatible with the light fixture.
- If the light flickers when dimmed, adjust the dimmer settings or consider using a different dimmer switch.
- Fixture buzzing with power outages:
- Contact our support team for further assistance.
If you require additional assistance, please feel free to contact our team of lighting experts. We are here to help brighten your day!
What’s in the Box?
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off the circuit breaker before installing this fixture.
- This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended.
- Abide by related regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, relocate, or remove wiring during installation.
- Do not make or alter any open holes in the wiring enclosure or electrical components during installation.
- Check for shipping damage before installing. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
- Suitable for damp locations at temperatures ranging from 4°F to 113°F. Not for use where directly exposed to water.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- Use safety precautions and abide by regional and local laws or regulations.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with occupancy sensors.
- This product is not compatible with timing devices.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
-
Step 1
Use the template to cut the hole. -
Step 2
Connect supply & junction wires. -
Step 3
Attach the fixture to the junction box. -
Step 4
Insert fixture into ceiling.
Installation Guide
- STEP 1
- Turn off the circuit breaker before installation.
- Cut out the 6.33” housing size on Installation Template, then tape it onto the ceiling in the desired location.
- Cut ceiling hole using Installation Template as a guide.
- STEP 2
- Open the junction box and remove the appropriate knockout.
- STEP 3
- Connect supply and junction wires using wire nuts:
- Black to Black (Live)
- White to White (Neutral)
- Tuck connected wires inside the junction box and close the cover.
- STEP 4
- Slide the CCT Selection Switch to choose from five color temperatures. Insert the junction box through the ceiling hole.
- New Construction Applications: Secure to studs, joists, or similar fixed structural units.
- Remodel Applications: Do not require secure studs, joists, or similar fixed structural units.
- STEP 5
- Attach the fixture to the junction box using the connector as shown in the image (1).b. Tighten the connector by hand (2).
- STEP 6
- Push up spring clips and insert fixture into ceiling.
- Turn on the circuit breaker and test the light.
Recommended Dimmers
Brand | Model |
---|---|
LUTRON | P-PKG1WB-WH |
LUTRON | MACL-153M-WH |
LUTRON | PD-6WCL-WH |
LUTRON | AYCL-153P-WH |
LUTRON | DVCL-153P-WH |
LEVITON | D26HD-2RW |
KASA SMART | HS220 |
KASA SMART | HS220P3 |
Scan for the full compatible dimmer list!
Specifications
Voltage | 120V | Average Lifetime | 50,000 hrs |
---|---|---|---|
Wattage | 14W | Lumens | 1500LM |
Wattage Equivalency | 120W | Moisture Rating | Damp |
Beam Angle | 90° | CRI | 90+ |
Weight | 0.6lbs | Usage | Indoor |
Housing Material | Plastic | IC Rated | Yes |
Dimmable | Yes | Warranty | 7 Years |
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy- to-follow solutions for any problem.
If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts is happy to help brighten your day.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles:
Asymmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as a beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry-leading 7-year warranty.
It gets even better – scan the QR code for 2 extra years of protection !
30-Day Return Policy
At Sunco we value our customers and stand by the quality and performance of our products.
If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all
your needs! Contact us at
- Email: support@sunco.com
- Text or Call: 844-334-9938 6AM – 6 PM PST Monday – Friday
Lighting made better
support@sunco.com 844-334-9938
AMERICAN COMPANY
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>