Allen-Bradley 58UHF Series RFID Short-Range Transceiver Instruction Manual
- June 12, 2024
- Allen Bradley
Table of Contents
- IMPORTANT INFORMATIONS
- Features
- Typical Applications
- Specifications
- Status Indicator Functionality
- Connector Pinouts
- FCC Notice (For U.S. Customers)
- ISED Information
- Declaration of Conformity
- Rockwell Automation Support
- Documentation Feedback
- Waste Electrical and Electronic Equipment (WEEE)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Allen-Bradley 58UHF Series RFID Short-Range Transceiver
IMPORTANT INFORMATIONS
Catalog Numbers 58UHF-TR-100-SR15US, 58UHF-TR-100-SR15EU
WARNING : Never disassemble or modify the scanner. Doing so could result in an accident such as fire or electric shock.
Features
-
Global Ultra-High Frequency (UHF) RFID solution
- 865…868 MHz EU and UK model (CE)
902…928 MHz US and North America model (FCC)
- 865…868 MHz EU and UK model (CE)
-
Tag compatibility: ISO 18000-63 (EPC global Gen2) compliant
-
Sensing range up to 1.5 m (4.92 ft)
-
Built-in status indicators for diagnostics
-
All-in-one linear and circular antennas
-
Excellent reliability in harsh environments
Typical Applications
- Asset tracking
- Data acquisition
- Product handling
- Automotive
- Food and pharmaceutical
Specifications
Attribute | Value |
---|---|
Enclosure rating | IP66/67 |
Operating temperature [°C (°F)] | -20…+55 (-4…+131) |
Storage temperature [°C (°F)] | -40…+85 (-40…+185) |
Relative humidity (1) |
- Operating: 35…95%
- Storage: 25…85%
Vibration| 10 g at 10…500 Hz
Shock resistance [g]| 50
Tag compatibility| ISO 18000-63
Sensing distance, max (2) [m (ft.)]| 1.5 (4.92)
Compliance| FCC, UL/cUL, CE, UKCA, and ISED
Connector|
- EtherNet/IP™: M12 4-pin plug DC Micro
- Power and I/O: M12 4-pin socket DC Micro
Communication protocol| EtherNet/IP
Supply voltage| 19.2…26.4V DC
Current consumption at 24V DC, max|
- Supply: 1 A CLASS2/SELVS
- Input: 15 mA
- Output: 0.5 A
Communication rate|
- RFID: 1024 bps
- Ethernet: 10/100 Mbps, half or full-duplex
Frequency|
- 865.7…867.5 MHz EU and UK model (at 600 kHz intervals, 4 channels total)
- 902.75…927.25 MHz US and North America model (at 500 kHz intervals, 50 channels total)
(1) No condensation
(2) The setting limits depend on the country or the function. This
reference value can vary depending on the operating environment tag type.
Status Indicator Functionality
Name | Description | State | Indicates |
---|---|---|---|
MOD | Indicates status of the transceivers | Off | No power |
Steady green | Device operational | ||
Flashing green | Standby (device has not been configured) | ||
Flashing red | Major recoverable fault | ||
Steady red | Major nonrecoverable fault | ||
Flashing green/red | Self-test (power-up testing) | ||
Link1/2 | Indicates status of Ethernet (E1/ E2) port | Off | No link |
Steady green | Link | ||
Steady yellow | Port disabled | ||
Flashing green | Port activity (data packets currently being exchanged) | ||
Flashing yellow | Collision | ||
Steady red | Major NIC fault | ||
NET | Indicates status of the connections | Off | No power or powered on with no |
IP address
Flashing green| No connections (IP address, but no CIP™ connections are
established, and an exclusive owner connection has timed out)
Steady green| Connected
Flashing red| Connection timeout
Steady red| Duplicate IP
Flashing green/red| Self-test (power-up testing)
R/W| Indicates status of the read/write commands| Off| No power
Steady green| Powered but idle
Flashing green| Transmitting RF carrier wave (no tags detected)
Steady yellow| Succeeded at tag operation (tag read/write complete)
Flashing yellow| Failed at tag operation (tag read/write incomplete)
Flashing red| RF transmit failure
IMPORTANT Installation must be in accordance with local and/or national codes. Servicing energized industrial control equipment can be hazardous if not in accordance to recommended safety procedures.
Connector Pinouts
Table 1 – EtherNet/IP (1)
DC M12, D-coded, 4-pin Plug | Pin | Signal | Color |
---|---|---|---|
1 | TxData + | White/orange | |
2 | Recv Data + | White/green | |
3 | TxData – | Orange | |
4 | Recv Data – | Green |
(1) E1 – Standard right-angle Ethernet cables point left.
E2 – Standard right-angle Ethernet cables point right.
Table 2 – Power I/O
DC M12, D-coded, 4-pin Socket | Pin | Signal | Color |
---|---|---|---|
1 | +24V DC | Brown | |
2 | Input | White | |
3 | 0V DC | Blue | |
4 | Output | Black |
FCC Notice (For U.S. Customers)
This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: (1) This device will not cause harmful interference; and (2) This device must accept any interference received, including interference that can cause undesired operation of the device. Changes and modifications that are not expressly approved by Rockwell Automation can void your authority to operate this equipment under Federal Communications Commissions rules.
This equipment is tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
ATTENTION: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, can cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you must correct the interference at your own expense.
IMPORTANT
This equipment complies with FCC radiation exposure limits for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. When you install and operate this equipment, keep a minimum of 35 cm (13.78 in.) between the radiator and a person’s body
ISED Information
This device complies with Innovation, Science and Economic Development Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference; and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
IMPORTANT
This equipment complies with ISED radiation exposure limits for an uncontrolled environment and meets RSS 102 of the ISED radio frequency (RF) Exposure rules. When you install and operate this equipment, keep a minimum of 35 cm (13.78 in.) between the radiator and a person’s body.
Declaration of Conformity
CE Conformity
Rockwell Automation, Inc. declares that the radio equipment type 58UHF-
TR-100-LR15EU is in compliance with the 2014/53/EU Radio Equipment Directive
and the 2011/65/EU RoHS Directive.
For a comprehensive CE certificate visit:
rok.auto/certifications.
UKCA Conformity
Rockwell Automation, Inc. declares that the radio equipment type
58UHF-TR-100-LR15EU is in compliance with the Radio Equipment Regulations
(2017 No. 1206) and the Restriction of the Use of Certain Hazardous Substances
in Electrical and Electronic Equipment Regulations (2012 No. 3032).
For a comprehensive UKCA certificate visit:
rok.auto/certifications. Türkiye
Cumhuriyeti: AEEE Yönetmeliðine Uygundur
Application | Frequency Range | Power |
---|---|---|
UHF RFID | 865…868 MHz | 2 W e.r.p. |
Rockwell Automation Support
Use these resources to access support information.
Technical Support Center| Find help with how-to videos, FAQs, chat, user
forums, Knowledgebase, and product notification updates.|
rok.auto/support
---|---|---
Local Technical Support Phone Numbers| Locate the telephone number for
your country.| rok.auto/phonesupport
Technical Documentation Center| Quickly access and download technical
specifications, installation instructions, and user manuals.|
rok.auto/techdocs
Literature Library| Find installation instructions, manuals, brochures,
and technical data publications.|
rok.auto/literature
Product Compatibility and Download Center (PCDC)| Download firmware,
associated files (such as AOP, EDS, and DTM), and access product release
notes.| rok.auto/pcdc
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
Waste Electrical and Electronic Equipment (WEEE)
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Connect With us.
expanding human possibility”
AMERICAS: Rockwell Automation, 1201 South Second Street, Milwaukee, WI
53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
EUROPE/MIDDLE EAST /AFRICA: Rockwell Automation NV, Pegasus Park, De Kleetlaan
12a, 1831 Diegem, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 ASIA
PACIFIC: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport
Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 25081846 UNITED KINGDOM:
Rockwell Automation Ltd. Pitfield, Kiln Farm Milton Keynes, MKll 3DR, United
Kingdom, Tel: (44)(1908) 838-800, Fax: (44 (1908) 261-917
Allen-Bradley, expanding human possibility, and Rockwell Automation are
trademarks of Rockwell Automation, Inc.
CIP and EtherNet/IP are trademarks of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their
respective companies.
Publication 58UHF-IN001A-EN-P – December 2022 | –
Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the
Japan 10007125910 Ver 00
References
- Product Certifications | Rockwell Automation
- Publication Feedback Form | Rockwell Automation
- Literature Library | Rockwell Automation
- Product Compatibility & Download Center from Rockwell Automation
- Product Environmental Compliance | Rockwell Automation
- Phone/Onsite Support
- Support | Rockwell Automation
- Technical Documentation Center | Rockwell Automation
- Login • Instagram
- Select a Region | Rockwell Automation
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>