Altronix RB7 Ultra Sensitive Multiple Relay Module Installation Guide
- June 4, 2024
- Altronix
Table of Contents
RB7
Ultra Sensitive Multiple Relay Module
Installation Guide
Overview:
RB7 Multiple Relay Module incorporates seven (7) isolated form “C” relay outputs that can be activated via positive (+) low current trigger inputs. Typical applications include the switching of alarm devices (eg. annunciator, signals, etc.) from PGM outputs of alarm panels or from another source.
Specifications:
- 12VDC to 24VDC selectable operation.
- Seven (7) independent (3VDC to 24VDC @ 2mA minimum) positive (+) triggers.
- Seven (7) isolated form “C” 1A/120VAC or 28VDC contacts.
Board dimensions (L x W x H): 6.5” x 3.25” x 1” (165.1mm x 82.6mm x 25.4mm).
Installation Instructions:
- Mount RB7 in the desired location/enclosure.
- Connect 12VDC to 24VDC power supply to the terminals marked [POS +] and either of the terminals marked [GND].
- Connect 3VDC to 24VDC positive (+) trigger to each trigger inputs marked [INP1 to INP7].
- Triggering input 1 (INP1) activates relay output 1 (OUT1). Input 2 (INP2) activates relay output 2 (OUT2), etc.
- Connect output devices to terminals marked [NC, C, NO] dry contacts.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056 website:
www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty
IIRB7 – Rev. 103001