CHAMPION 100396 3400W Dual Fuel Electric Start Inverter Generator User Guide

October 31, 2023
Champion

3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR
QUICK START GUIDE
CHAMPION 100396 3400W Dual Fuel Electric Start
Inverter

PARTS INCLUDED

CHAMPION 100396 3400W Dual Fuel Electric Start Inverter -
parts

WARNING
Read the ENTIRE operator’s manual to become familiar with the featur of this product before operation. This Quick Start Guide IS NOT a substitute for the Operator’s Manual.
Failure to operate the product correctly could result in damage to the product, personal property or cause serious injury or death.

TAKEYOURGENERATOROUTSIDE.COM

Set Up

Add oil. Assembly > Add Engine Oil.
Recommended: 5W-30, up to 20.3 fl. oz. (600 ml) DO NOT overfill.CHAMPION
100396 3400W Dual Fuel Electric Start Inverter - setup

Move the generator outdoors.
Move generator to an open, outdoor area.
Point exhaust away from people and buildings.
Never run generator inside a home or garage.CHAMPION 100396 3400W Dual Fuel
Electric Start Inverter - outdoors

Keep all objects at least 5 feet (1.5 m) from generator. Heat from the muffler and exhaust gas can ignite combustible materials.

Add fuel – Gasoline or Propane (LPG) Assembly > Add Fuel

FOR GASOLINE OPERATION: DO NOT USE E15 OR E85CHAMPION 100396 3400W Dual Fuel
Electric Start Inverter - Gasoline

Connect the battery. Assembly > Connect the Battery.
Attach the red battery lead to the positive red terminal on the battery.
Repeat for the black negative battery lead.CHAMPION 100396 3400W Dual Fuel
Electric Start Inverter - battery

Fuel Selection. Operation > Fuel Selector Switch.
Gasoline: “Horizontal” position.
Propane: “Vertical” position.

Start Up

DO NOT plug in any electrical devices.

NEVER START OR STOP THE GENERATOR WITH ELECTRICAL DEVICES CONNECTED OR TURNED ON!
Pull the choke knob out to the “CHOKE” position.

Starting the Engine: Gasoline

Electric Start

  1. Push the battery switch to the “ON” position.
  2. Press and hold the ignition switch to the “START” position.
  3. Pull the choke knob out of the “RUN” position.

Manual Start

  1. Push the battery switch to the “ON” position.
  2. Push the ignition switch to the “ON” position.
  3. Pull the starter cord.
  4. Pull the choke knob out of the “RUN” position.

Starting the Engine: Propane (LPG)

Electric Start

  1. Open the propane tank valve.
  2. Push the battery switch to the “ON” position.
  3. Press and hold the ignition switch to the “START” position.
  4. Pull the choke knob out of the “RUN” position.

Manual Start

  1. Open the propane tank valve.
  2. Push the battery switch to the “ON” position.
  3. Push the ignition switch to the “ON” position
  4. Pull the recoil 1-2 times to prime the engine.
  5. Push the chob knob in to the “RUN” position.
  6. Pull the recoil to start the engine.
    CHAMPION 100396 3400W Dual Fuel Electric Start Inverter - Switch
5

Plug in. Operation > Connecting Electrical Loads.

NEED ASSISTANCE OR HAVE A QUESTION?
GIVE US A CALL.
1-877- 338-0999
CHAMPIONPOWEREQUIPMENT.COM

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>