Sunco DL_SL6-BR 6 Inch LED Selectable Slim Downlight User Manual
- June 12, 2024
- SUNCO
Table of Contents
Lighting made better.
User Manual
6” LED Selectable Slim
Downlight (Metal Trim)
SKU: DL_SL6-BR; DL_SL6-NK
What’s in the Box
Slim Downlight
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off circuit breaker before installing this fixture.
- This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended.
- Abide by related regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, relocate, or remove wiring during installation.
- Do not make or alter any open holes in wiring enclosure or electrical components during installation.
- Check for shipping damage before installing. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
- Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- Use safety precautions and abide by regional and local laws or regulations.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with occupancy sensors.
- This product is not compatible with timing devices.
WARNING: cancer , and Reproductive Harm – www.P65Warnings.ca.gov
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
QuickStart Guide
Installation Guide
STEP 1
a. Turn off circuit breaker before installation.
b. Cut out 6.33” housing size on Installation Template, then tape onto ceiling
in desired location.
c. Cut ceiling hole using Installation Template as a guide.
STEP 2
a. Open junction box and remove appropriate knockout.
STEP 3
a. Connect supply and junction wires using wire nuts:
-Black to Black (Live)
-White to White (Neutral)
b. Tuck connected wires inside junction box and close the cover.
STEP 4
Note: This step applies exclusively to the Selectable Retrofit.
Slide the CCT Selection Switch to choose from five color temperatures. Insert
junction box through ceiling hole.
New Construction: Secure to studs, joists, or similar fixed structural units.
Remodel: Do not require to secure to studs, joists, or similar fixed
structural units.
STEP 5
a. Attach fixture to junction box using connector as shown on image (1).
b. Tighten connector by hand (2).
STEP 6
a. Push up spring clips and insert fixture into ceiling.
b. Turn on circuit breaker and test light.
Product Details
Recommended Dimmers
Brand | Model |
---|---|
LUTRON | P-PKG1WB-WH |
LUTRON | MACL-153M-WH |
LUTRON | PD-6WCL-WH |
LUTRON | AYCL-153P-WH |
LUTRON | DVCL-153P-WH |
LEVITON | D26HD-2RW |
KASA SMART | HS220 |
KASA SMART | HS220P3 |
Scan for the full compatible dimmer list
Specifications
Voltage | 120V | Average Lifetime | 50,000 hrs |
---|---|---|---|
Wattage | 14W | Lumens | 850LM |
Wattage Equivalency | 120W | Moisture Rating | Damp |
Beam Angle | 90° | CRI | 90+ |
Weight | 0.7lbs | Color | Bronze, Nickel |
Housing Material | Plastic; Metal Trim | IC Rated | Ye s |
Dimmable | Ye s | Warranty | 7 Years |
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our
troubleshooting section is here to shed some light and provide you with easy-
to-follow solutions for any problem.
If you still need some assistance, please feel free to contact us with any
questions. Our team of lighting experts are happy to help brighten your day.
Installation
Light isn’t turning on.| Double check if fixture is properly connected and
circuit breaker hasn’t been tripped.
Light isn’t bright enough.| Check proper wattage and for unobstructed fixture.
Dimming
Light not dimming to lowest setting.| Ensure minimum dimmer load requirement
is met.
Light not dimming smoothly.| Verify dimmer compatibility with fixture.
Light not compatible with dimmer switch.| Check light-dimmer compatibility.
Consider purchasing compatible switch if necessary.
Flickering
Light is flickering when turning on.| Check that fixture wiring connections
are secure.
Light flickering with other lights on the same circuit.| Check that the lights
on the same circuit are not overloading the circuit.
Light flickering when turned on.| Verify fixture compatibility and that it is
grounded.
Light flickering when dimmed.| Verify dimmer switch compatibility.
Buzzing
Fixture buzzing with power outages.| Verify light is connected to surge
protector securely.
Fixture buzzing with appliances or electronic devices.| Look for nearby
interferences that can cause buzzing. Such as televisions, radios, computers,
etc.
Fixture buzzing when dimmed.| Verify dimmer switch compatibility.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light
source. It is an important factor to consider when selecting a fixture or
bulb, as it affects the way it will illuminate an area. There are two main
types of lighting distribution angles:
A symmetric lighting distribution emits light evenly in all directions,
creating a cone-shaped pattern that provides a pool of light. This type of
lighting is ideal for general lighting and illuminating large areas. Common
applications for symmetric lighting include general area illumination,
security lighting, and perimeter lighting. Symmetric lighting is also used to
a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as beam angle, creates a
pattern that focuses light in a specific direction. This type of lighting is
ideal for task lighting as it reduces glare and light spill in other areas.
Common applications include task lighting in spaces such as landscape
settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be
affected by other factors such as the reflector design of the light source,
the type of lens used, and the distance between the light source and the
surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry leading 7 year warranty.
It gets even better – scan the QR code for 2 extra years of protection!
Scan me for two extra years!
https://www.sunco.com/pages/warranty
30 Day Return Policy
At Sunco we value our customers and stand by the quality and performance of
our products.
If you are not completely satisfied with your purchase, we accept returns
within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all
your needs! Contact us at:
Lighting made better.
Email: support@sunco.com
Text or Call:
844-334-9938
6AM – 6PM PST Monday – Friday
AMERICAN COMPANY
Documents / Resources
|
Sunco DL_SL6-BR 6 Inch LED Selectable Slim
Downlight
[pdf] User Manual
DL_SL6-BR, DL_SL6-NK, DL_SL6-BR 6 Inch LED Selectable Slim Downlight, 6 Inch
LED Selectable Slim Downlight, LED Selectable Slim Downlight, Selectable Slim
Downlight, Slim Downlight, Downlight
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>