MAYTAG MG2R Gas Furnace Instruction Manual
- June 12, 2024
- Maytag
Table of Contents
MAYTAG MG2R Gas Furnace
For 80+ and 90+ Single Stage Furnaces
Refer to the Installation Instructions provided with the furnace for the
proper heating and cooling speeds for your application.
Red LED Flash | Error/Condition |
---|
Flash codes stored in memory (auto-erased after 14 days)
1| System Lockout (Retries Exceeded)
2| Pressure Switch Stuck Closed
3| Pressure Switch Stuck Open
4| Open High Temperature Limit Switch
5| Flame Sensed>4.25 Seconds with Gas Valve De-Energized
6| Open Flame RO Switch
8| Ignitor Relay Error
10| Open Fuse
11| Ignitor Open
12| Inducer Relay Error
Flash codes NOT stored in memory
7| Low Flame Sense Signal
9| Twinning Fault
Off| Control Failure / No Power / Internal Fault / IRQ Loss
Gas Heating Lockout (Gas valve energized when it should be de-energized)
Or Gas valve De-energized when it should be Energized
Rapid Flash| Reverse Polarity
Continuous On| Normal Operation
If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temperature of at least 105 C.
Use copper conductors only.
Cool Motor SPEED DIPSWITCH SETTING (S1-1, S1-2, S1-3)
| | 1| 2| 3| 1| 2| 3| 1| 2| 3| 1| 2| 3| 1| 2| 3| 1| 2| 3| 1| 2| 3| 1| 2| 3
| Position| OFF OFF OFF| ON OFF OFF| ON ON OFF| OFF ON OFF| OFF OFF ON| OFF ON
ON| ON OFF ON| ON ON ON
Motor SPEED Cool| Y| T1| T2| T3| T4| T1+T2| T1| T1| T1
Heat Motor SPEED DIPSWITCH SETTING (S2-1, S2-2)
| | 1| 2| 1| 2| 1| 2| 1| 2
| Position| OFF OFF| ON OFF| ON ON| OFF ON
Motor SPEED Heat| W| T1| T2| T3| T4
Fan Motor SPEED DIPSWITCH SETTING (S2-3, S2-4)
| | 1| 2| 1| 2| 1| 2| 1| 2
| Position| OFF OFF| ON OFF| OFF ON| ON| ON
Motor SPEED Fan| G| T1| T2| T4| T1+T2
WIRING DIAGRAM