Marson Technology MT6228 2D Fixed Mount Scanner User Guide
- June 13, 2024
- Marson Technology
Table of Contents
MT6228
Fixed Mount Scanner
Quick Guide
Out of Box
Introduction
1 | Good Read LED |
---|---|
2 | Tuning Mode LED |
3 | No Read LED |
4 | Power On LED |
5 | Tuning Button / Scan Button |
6 | Mechanical Knob For Lens Focus |
I/O Box
PIN | Signal | Function |
---|---|---|
1 | Opto Isolated Input(-) | Trigger Input |
2 | Opto Isolated Input(+) | |
3 | VCC (+) | 5-36 VDC |
4 | GND (-) | |
5 | Opto Isolated Ouput (-) | Good Read |
Indicator
6| Opto Isolated Output (+)
7| Opto Isolated Output (-)| No Read
Indicator
8| Opto Isolated Output (+)
Installation
Above is an installation example:
- Connect the scanner with I/O Box via aviation plug
- Connect 5~36V DC power, which is not needed when applying USB cable.
- Connect I/O Box with PC or data terminal via RS232/USB/Ethernet.
- If external trigger mode is used, an external sensor or PLC is needed.
- If OK or NG signal is needed, connect Pin 5~8 to external device.
Input Diagram
NPN Photoelectric Switch Input
PNP Photoelectric Switch Input
Relay Photoelectric Switch Input
Output Diagram
Good Read(OK)
No Read(NG)
Specifications
Performance|
---|---
Resolution| 1280 x 800
Scan Angle| Horizontal 28° (H), Vertical 33° (V)
1D Symbologies| UPC A , UPC E , EAN 8, EAN 13 , Code 128 , Code 39, Code 93,
Code 32, Code11 , Codabar, Plessey, MSI , Interleaved 2 of 5 , IATA 2 of 5 ,
Matrix 2 of 5 , Straight 2 of 5 , Pharmacode , RSS-14 , RSS-14 Expanded ,
RSS-14 Limited , Composite Code-A Composite Code-B , Composite Code-C
2D Symbologies| PDF 417 , Micro PDF 417 , Data Matrix , QR , Micro QR , Aztec
, MaxiCode
Motion Tolerance| Continuous Mode : 1M / sec External Trigger Mode : 2M / sec
Connectivity
Interface| RS232, USB (HID; CDC), Ethernet (TCP/UDP)
External Input| 1 Optoisolated Input (NPN/PNP/Relay)
External Output| 2 Optoisolated Output (Good/NG)
Power| 5-36 VDC
Physical Characteristics
Dimension| 44 (W) x 52 (D) x 29 (H) mm
Material| Aluminum Alloy
Sealing| IP65
User Environment
Storage Temp.| -40°C-+70°C
Operating Temp.| -20°C – + 50°C
Regulatory| TBA
Depth of Field
Lens Focus | LR (Long Range) | HD (High Density) |
---|---|---|
Resolution | 1D : ≥5 mil ; 2D :≥9 mil | 1D: ≥3 mil ; 2D: ≥7mil |
DOF | Code39 (5 mil) : 150 mm – 300 mm EAN -13 (13 mil) : 115 mm – 550 mm QR | |
Code (11 mil) : 125 mm – 250 mm | Code39 (3 mil) : 85 mm – 120 mm EAN-13 (13 |
mil) : 75 mm – 245 mm QR Code (7 mil) : 80 mm – 150 mm
Field of View
Distance (mm) | Field of View (mm) |
---|---|
Horizontal (mm) | Vertical (mm) |
100 | 53 |
150 | 79 |
200 | 106 |
Dimensions
Auto-tuning
-
Press and hold the Tune Button for about 5 seconds.
-
Aim at the desired barcode. Release the Tune Button to start Auto-tuning.
-
LED status indicates Auto-tuning result (Error or Good). If the result is Good, the settings will be stored permanently. No need for re-tuning after a power cycle. If the result is Error, please start over from step 1.
Troubleshooting
If the scanner does not work properly, please do the following first:
- Check if the cable is connected firmly and is supplied by original manufacturer.
- Check if the symbology (barcode type) is enabled.
- Check if the barcode quality is good.
If the scanner still does not work properly, please contact your local distributor.