Honeywell TH9320WF Smart Thermostat 9000 Color Touchscreen Installation Guide
- June 13, 2024
- Honeywell
Table of Contents
- TH9320WF Smart Thermostat 9000 Color Touchscreen
- Read and save these instructions Wallplate installation
- Wiring
- Initial setup
- System setup
- Connecting to the Wi-Fi network
- Setting advanced preferences
- Troubleshooting
- Accessories & replacement parts
- Specifications
- Regulatory information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Smart Thermostat 9000
Color Touchscreen
TH9320WF
TH9320WF Smart Thermostat 9000 Color Touchscreen
Read and save these instructions Wallplate installation
- Separate wall plate from thermostat.
- Mount wall plate as shown below.
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash.
Wiring
Terminal Designations
C | Common wire from secondary side of cooling transformer (if 2 transformers). |
---|---|
K | Optional C-wire adaptor. |
Rc | Cooling power. Connect to secondary side of cooling system transformer. |
R | Heating power. Connect to secondary side of heating system transformer. |
W-O/B | 1st stage heat relay. Or changeover valve for heat pumps. |
Y | 1st stage compressor contactor. |
G | Fan relay. |
W2-Aux/E | 2nd stage heat relay. Or heat pump auxiliary/Emergency heat relay. |
Y2 | 2nd stage compressor contactor. |
L | Heat pump system monitor. |
Jumper Loop, a plug with a wire loop used to connect the R to the Rc |
terminals, Leave jumper loop in place in single transformer systems. Remove (unplug) jumper loop in two transformer systems.
Wiring guide — conventional systems
Wiring Instructions
-
This thermostat requires a 24Vac common to power the thermostat. The K terminal is available for
C-wire adaptor (THP9045A1098). -
Straighten the wire. Using a pen tip to hold down the terminal, gently slide the wire into terminal hole.
Note: Terminal hole will only accept one wire.
1H/1C System (1 transformer)|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
Y| Compressor contactor
C| 24VAC common
G| Fan relay
Heat-only System|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
C| 24VAC common
W| Heat relay
1H/1C System (2 transformers)|
---|---
Rc| Power (cooling transformer) [1, 2]
R| Power (heating transformer) [1, 2]
Y| Compressor contactor
W| Heat relay
G| Fan relay
Heat-only System with Fan|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
C| 24VAC common
G| Fan relay
Cool-only System|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
Y| Compressor contactor
Cool-only System| 24VAC common
G| Fan relay
2H/2C System
(1 transformer)|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
Y| Compressor contactor (stage 1)
W| Heat relay (stage 1)
G| Fan relay
W2| Heat relay (stage 2)
Y2| Compressor contactor (stage 2)
2H/2C System
(2 transformer)|
---|---
Rc| Power (cooling transformer) [1, 2]
R| Power (heating transformer) [1, 2]
Y| Compressor contactor (stage 1)
C| 24VAC common [3]
W| Heat relay (stage 1)
G| Fan relay
W2| Heat relay (stage 2)
Y2| Compressor contactor (stage 2)
See [notes] below
Jumper Loop
NOTES
Wire specifications:
Use 18- to 22-gauge thermostat wire.
Shielded cable is not required.
[1] Power supply. Provide disconnect means and overload protection as
required.
[2] Remove jumper loop for 2-transformer systems.
[3] Common connection must come from cooling transformer.
Wiring guide — heat pump systems
Wiring Instructions
-
This thermostat requires a 24Vac common to power the thermostat. The K terminal is available for
C-wire adaptor (THP9045A1098). -
Straighten the wire. Using a pen tip to hold down the terminal, gently slide the wire into terminal hole.
Note: Terminal hole will only accept one wire.
1H/1C Heat
Pump System|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
Y| Compressor contactor
C| 24VAC common
O/B| Changeover valve [7]
G| Fan relay
2H/1C Heat
Pump System|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
Y| Compressor contactor
C| 24VAC common
O/B| Changeover valve [2]
G| Fan relay
Aux/E| Auxiliary/Emergency heat relay
L| Heat pump system monitor
3H/2C Heat Pump System|
---|---
Rc| Power [1]
R| [R+Rc joined by jumper loop]
Y| Compressor contactor (stage 1)
O/B| Changeover valve [2]
G| Fan relay
Aux/E| Auxiliary/Emergency heat relay
Y2| Compressor contactor (stage 2)
L| Heat pump system monitor
See [notes] below
Jumper Loop
NOTES
Wire specifications:
Use 18- to 22-gauge thermostat wire. Shielded cable is not required.
- Power supply. Provide disconnect means and overload protection as required.
- In Setup, set changeover valve to O or B.
Initial setup
Upon initial power up, or after being reset to factory defaults, the initial
thermostat options (language, location, and system type) must be set to define
the heating/ cooling system. Other options can be customized later.
Follow prompts on the screen to select appropriate options.
-
Touch the language you want the thermostat to display, then touch Next.
-
Select Home or Business installation, then touch Next.
-
Touch Next, or name the thermostat location—touch THERMOSTAT and follow the rest of the instructions.
-
Select what the thermostat will control and touch Next.
Note: Touch the orange Help button on any screen for more information. -
Select the system type and touch Next. The system type determines other selections for completing initial setup.
-
Touch Next after making selections on each screen.
-
Touch Done on the last screen. The thermostat displays an option to connect to the Wi-Fi network.
System setup
From the home screen, touch Menu > System Setup to modify the initial system setup.
System Setup Options (MENU > System Setup)
Screen Title | Settings and Options |
---|---|
Language | Eng lish/Francais/ EsparioL |
Thermostat installed in | Home/Business (Thermostat is used in a residential |
(default) or commercial setting).
Your thermostat location| Touch THERMOSTAT button to display a screen where
you can enter a custom name using a keypad. If you have only one thermostat,
you can leave the name as THERMOSTAT. For business installations you can check
a box to display the thermostat name on the home screen.
Your thermostat controls| Select Heating or Cooling or both (default).
Your system type| Select Forced Air (default), Heat Pump, or Hot Water or
Steam. Each option offers different choices on the following screens.
Your forced air heating system type| Select how your forced air system is
powered: Gas/Oil (default) or Electric.
Efficiency of your heating system| Select Standard Efficiency Forced Air
(default) or High Efficiency Forced Air.
Your heating system type| If you selected Hot Water or Steam on ‘Your system
type: select the specific heating system here.
Number of cooling stages| Select 1 Stage (default) or 2 Stages. If you are
unsure, note which wires are connected: ‘Y’ wire only (1 stage) or ‘Y’ and
‘Y2’.
Number of heating stages| Select 1 Stage (default) or 2 Stages. If you are
unsure, note which wires are connected: W wire only (1 stage) or W and W2′.
Your fan control| Select whether your thermostat (default) or heating system
controls the fan.
Type of changeover valve| If you selected Heat Pump on ‘Your system type,”
select whether it uses a cooling changeover valve (default) or heating
changeover valve.
Number of heat pump compressor stages| Select 1 Stage (default) or 2 Stages.
If you are unsure, note which wires are connected: Y wire only (1 stage) or
‘V’ and ‘Y2’.
Your backup heat| No or Yes (default)
Connecting to the Wi-Fi network
After the initial setup, walk the homeowner through connecting to a Wi-Fi network. Or, refer the homeowner to the User’s Guide, so the homeowner can connect the thermostat to a Wi-Fi network at a later time.
-
Connect the Wi-Fi network.
Touch Yes to connect the thermostat to the Wi-Fi network. The screen displays the message “Searching for wireless networks. Please wait…” after which it displays a list of all Wi-Fi networks it can find. Note: If you cannot complete this step now, touch I’ll do it later. The thermostat will display the home screen. Complete this process by selecting MENU > Wi-Fi Setup. Continue with Step 2. -
Select the network.
2a Touch the name of the homeowner’s network. The thermostat displays a password page.
Note: If the home network is not shown on the list, touch Rescan.
2b Using the keyboard, touch the characters that spell out the home network password.
2c Touch Done. The thermostat displays “Connecting to your network. Please wait…” then shows a “Connection Successful” screen.
2d Touch Next to display the registration information screen.
2e Have the homeowner register the thermostat by going to http://www.mytotalconnectcomfort.com
Note the Thermostat MAC and CRC; they’ll be needed during registration. Or, refer the homeowner to the User’s Guide.
Note: The Register Online screen remains active until you complete registration and/or touch Done. -
For remote access, the homeowner or end-user must register at mytotalconnectcomfort.com
Setting advanced preferences
-
Touch MENU. The thermostat displays a list of options.
-
Select Preferences > Advanced Preferences. The thermostat displays the first screen of options that you can change.
-
On each screen, make changes as needed, then touch Next to display new options. Repeat this step until you have made all changes.
-
When you have made all changes, press Done to save and exit.
Screen Title | Settings and Options |
---|---|
Scheduling Options | Select Non-programmable or Programmable. Programmable uses |
default or customized programming to automatically raise and lower temperature
settings for different times of day.
Temperature Indication Scale| Select Fahrenheit or Celsius.
Heating and Cooling System Changeover| Select Manual or Automatic.
Number of Schedule Periods| Select 2 Periods Per Day or 4 Periods Per Day.
Pre-occupancy Purge Duration •| Select how long the fan will run before each
occupied period: Off, 1, 2, or 3 hours.
Type of Override*| Select Standard to maintain the programmed periods or
Initiate Occupancy to use energy-saving settings until a user presses Start
Occupancy.
Override Duration •| Select how long to maintain temperature during an
override: 1-10 hours or No Limit.
Early Recovery for Heating’| Select No to begin recovery on schedule or Yes to
ramp up temperature early.
Early Recovery for Cooling •| Select No to begin recovery on schedule or Yes
to ramp down temperature early.
Temperature Limits| Select the Minimum Cool and Maximum Heat Limit.
Keypad Lockout| Select Unlocked/Partially Locked/Locked.
Clock Format| Select 12 Hour or 24 Hour.
Daylight Saving Time| Select Off or On. If set to On, the system will
automatically change time/date to account for daylight saving.
Indoor Display Offsets| Select the number of degrees to offset indoor
temperature or percentage to offset indoor humidity.
*Available when thermostat is installed in Business mode.
Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.
Display is blank| • Check circuit breaker and reset if necessary.
• Make sure power switch at heating and cooling system is on.
• Make sure furnace door is closed securely.
• Make sure C wire is connected.
---|---
Cannot change system setting to Cool| • Check that System Setup screen “Your
thermostat controls” or “Your system type” is set to match your heating and
cooling equipment.
Fan does not turn on when heat is required| • Check that System Setup screen
“Your fan control” is set to match your heating equipment.
“Wait” appears on the screen| • Compressor protection feature is engaged. Wait
5 minutes for the system to restart safely, without damage to the compressor.
Heat pump issues cool air in heat mode, or warm air in cool mode| • Check your
settings for correct system setup. See “Type of changeover valve” on page 7.
Heating or cooling system does not respond| • Touch SYSTEM to set system to
Heat. Make sure the temperature is set higher than the Inside temperature.
• Touch SYSTEM to set system to Cool. Make sure the temperature is set lower
than the Inside temperature.
• Check circuit breaker and reset if necessary.
• Make sure power switch at heating and cooling system is on.
• Make sure furnace door is closed securely.
• If “Wait” is displayed, the compressor protection timer is on. Wait 5
minutes for the system to restart safely, without damaging the compressor.
Heating system is running in cool mode| • Check that System Setup screen “Your
thermostat controls” or “Your system type” is set to match your heating and
cooling equipment .
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Cover plate assembly ………………….Part Number THP2400A1027W
Specifications
Temperature Ranges
- Heat: 40° to 90°F (4.5° to 32°C)
- Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
- 32° to 120°F (0° to 48.9°C)
Shipping Temperature
- -20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
- 5% to 90% (non-condensing)
Physical Dimensions
- 4-1/2″ W x 3-1/2″ H x 7/8” D (115 mm W x 88 mm H x 22 mm D)
Electrical Ratings
Terminal | Voltage (50/60Hz) | Max. Current Rating |
---|---|---|
W-O/B | 20-30 Vac | 1.0 A |
W2 (Aux/E) | 20-30 Vac | 1.0 A |
Y Cooling | 20-30 Vac | 1.0 A |
Y2 Cooling | 20-30 Vac | 1.0 A |
G Fan | 20-30 Vac | 0.5 A |
Regulatory information
FCC REGULATIONS
47 CFR § 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
47 CFR § 15.21 (USA only)
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
47 CFR § 15.105 (b)
See https://customer.resideo.com/en-US/support/residential/codes-and-
standards/FCC15105/Pages/default.aspx for additional FCC information for this
product.
IC REGULATIONS
RSS-GEN
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The operation of this equipment is subject to the following two conditions: (1) this equipment or device may not cause harmful interference, and (2) this equipment or device must accept any interference, including interference that may cause undesired operation.
DISCONNECT POWER BEFORE INSTALLATION. Can cause electrical shock or
equipment damage.
MERCURY NOTICE: If this product is replacing a control that contains
mercury in a sealed tube, do not place the old control in the trash. Contact
the Thermostat Recycling Corporation at www.thermostat-
recycle.org or
800-238-8192 for information on how and
where to properly and safely dispose of your old thermostat.
Need Help?
For assistance with this product please visit http://customer.resideo.com
or call Resideo Customer Care toll-free at
1-800-468-1502
IFT: RCPHOTH15-1247
Resideo Inc., 1985 Douglas Drive North
Golden Valley, MN 55422
69-2815EFS—07 M.S. Rev. 04-19 | Printed in United States
Wi-Fi® is a registered trademark of
Wi-Fi Alliance®
©2019 Resideo Technologies, Inc.
This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN,
1-800-633-3991.
The Honeywell Home trademark is used under license from Honeywell
International Inc. All rights reserved.
Connected by the TCC app
® U.S. Registered Trademark. Patents pending. Copyright © 2019 Resideo.
All rights reserved.
References
- Resideo Customer Portal
- Honeywell | Total Connect Comfort
- Honeywell | Total Connect Comfort
- Home - Thermostat Recycling Corporation (TRC)
- Resideo Customer Portal
- Resideo Customer Portal
- Support Materials & Resources | Resideo