Honeywell RCHT9510WFW2001 T9 Smart Thermostat Installation Guide

June 13, 2024
Honeywell

Honeywell RCHT9510WFW2001 T9 Smart Thermostat

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-PRODUCT-
IMAGE

Product Information

The T9 Smart Thermostat is a state-of-the-art thermostat designed for efficient and convenient temperature control in your home. It comes in several models: RCHT9510WFW2001, RCHT9510WFW2017, RCHT9610WFSW2003, and RCHT9610WFSW2019. The thermostat is equipped with a wireless room sensor (included with RCHT9610WFS models) and can be connected to your home Wi-Fi network for remote access and control. It also includes a UWP wallplate, wire labels, screws and anchors, as well as a C-Wire Adapter for optional use.

Product Usage Instructions

  1. Before installing the T9 Smart Thermostat, read the installation guide available at honeywellhome.com.
  2. Make sure you have the following tools ready: Phillips screwdriver, small flat head screwdriver, pencil, level, and your home Wi-Fi password. You may also need a wire stripper, needle-nose pliers, drill and drill bit, and a flashlight.
  3. Caution: Before starting the installation, disconnect the power to your heating and cooling equipment to avoid electrical shock or equipment damage. This can be done by turning off the power at the breaker box or switch that controls the equipment.
  4. Caution: During testing, the compressor protection is bypassed. To prevent equipment damage, avoid cycling the compressor quickly.
  5. Caution: If the T9 Smart Thermostat is replacing a control that contains mercury, do not dispose of the old control in the trash. Contact your local waste management authority for recycling and proper disposal instructions.
  6. If you need help, refer to the online guides and support videos at HoneywellHome.com/support. You can also contact Honeywell Home via email at Honeywellhomesupport@honeywellhome.com or phone at 1-800-633-3991.
  7. Removing your old thermostat:
  8. Turn off the power at the breaker box or switch that controls your heating and cooling equipment to protect your equipment.
  9. Check that your system is off by changing the temperature on your old thermostat. If you don’t hear or feel the system turn on within 5 minutes, the power is off.
  10. Remove your existing thermostat from the wall plate by gently pulling or using screws, buttons, or clasps. Do not remove any wires at this time.
  11. Compatibility Check:
  12. Check if you have a line voltage system. Line voltage systems have thick black wires with wire nuts or are labeled high voltage (120V or higher). If you have a line voltage system, the T9 Smart Thermostat is not compatible. Visit honeywellhome.com/contacta-pro to find a professional installer in your area.
  13. If you don’t have a line voltage system, continue to the next step.
  14. Take a picture of your existing wall plate’s wiring from different angles to capture all the letters next to the terminals. This image may be needed for reference later.
  15. Remove any jumpers connecting two terminals. Keep the jumpers with your old wallplate and do not discard them.
  16. Label each wire on your existing wall plate using the stickers provided with your new thermostat. Do not label jumpers. Note that your new thermostat does not require jumpers.
  17. Write down the colors of the wires for reference.

Read before installing.

Included in your box:

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-01

Tools you will need:

You may need: Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-03

Compatibility Section

REQUIRED : A C-Wire (common wire) is needed for 24 VAC power. If you do not have a C-Wire, then a C-Wire Adapter is provided.
This guide will help you determine if you have a C-Wire or will need to use the included C-Wire Adapter (Step 10). The C-Wire is a wire that originates from your heating and cooling system and needs to be connected to the C terminal on your thermostat. There is no universal color used to designate this type of wire.

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-04

  • Compatible with most heating/cooling, and heat pump systems
  • Does not work with electric baseboard heat (120-240V)
  • Does not work with millivolt systems
  • Does not support S terminals for indoor and outdoor sensors
  • Android or iOS smartphone, tablet, or device

CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

For help, see:
ONLINE GUIDES AND SUPPORT VIDEOS AT: HoneywellHome.com/support
SOCIAL
Twitter: @Honeywell_Home,
Facebook: Honeywell Home

Or contact:
EMAIL Honeywellhomesupport@honeywellhome.com
PHONE 1-800-633-3991

Removing your old thermostat
You will need: Screwdriver, needle-nose pliers

  1. Turn off power
    To protect your equipment, turn off the power at the breaker box or switch that controls you heating and cooling equipment.
    Note: The thermostat off switch will not turn off the power to the equipment. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-05

  2. Check that your system is off
    Change the temperature on your old thermostat so that your system starts heating or cooling.
    If you don’t hear or feel the system turn on within 5 minutes, the power is off.
    Note: If you have a digital thermostat that has a blank display, skip this step. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-06

  3. Remove your existing thermostat from the wall plate
    On most thermostats, you can take off the thermostat by grasping and gently pulling. Some thermostats may have screws, buttons, or clasps.
    Do not remove any wires from your thermostat at this time! Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-07

  4. Do you have a line voltage system?
    Line voltage systems have thick black wires with wire nuts or are labeled high voltage (120V or higher).
    YES
    Your system is not compatible. Go to honeywellhome.com/contact-a-pro to find a pro installer in your area.
    NO
    Continue to the next step. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-08

  5. Take a picture of your existing wall plate’s wiring
    In order to capture all of the letters next to the terminals, be sure to take multiple pictures from different angles.
    You may need to reference this image later. Honeywell-RCHT9510WFW2001-T9
-Smart-Thermostat-09

  6. Remove any jumpers
    A jumper is used to connect two terminals. It may look like a small staple or a colored wire.
    Do not discard.
    Keep jumpers with your old wallplate. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-10

  7. Label the wires
    Use the stickers provided with your new thermostat to label each wire on your existing wall plate.
    Do not label jumpers. Your new thermostat does not need jumpers. Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-11

  8. Write down the colors of the wires
    Check the boxes and write down the color of the wires connected to terminals that are coming from the wall. Check all that apply (not all will apply).
    Terminal Wire Color
    A or L/A ¨ R
    C Required* ¨ Rc
    E ¨ Rh
    G ¨ W
    K ¨ W2 or Aux
    O/B ¨ Y
    U (1 or 2)** ¨ Y2

  • A C-wire or C-Wire Power Adapter (included) is required.
    ** The T9 Smart thermostat cannot control equipment wired to U1 or U2.
    If there are wires in terminals that are not listed, you will need additional wiring support. Visit HoneywellHome.com/support to find out more.

    1. Disconnect the wires and remove the old wall plate
      You may need a screwdriver to release wires from terminals. Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-12Tip: Wrap the wires around a pencil to prevent them from falling in the wall.

    2. Do you have a C-Wire?
      Look at the thermostat wiring checklist from Step 8, or the photo you took. Is the C-Terminal checked?
      YES
      This means you will not need to install the included C-Wire Adapter. Skip to Installing Your New Thermostat (page 9).
      NO Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-13

    3. Do you have a zoning panel?
      You have a zoning panel if you have multiple thermostats and one furnace or heating system.
      YES
      C-Wire Adapter installation is more complicated on zoned systems. Go to honeywellhome.com/contact-a-pro to find a pro installer in your area.
      NO
      Proceed to the next step. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-14

    4. Do you have an unused wire?
      Look at the bundle of wires coming from the wall.
      Note: You may have to pull the bundle of wires out from the wall to find the unused wire.
      YES
      Continue to Step 13.
      NO
      Open the included C-Wire Adapter box and follow the instruction guide. Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-15

    5. Label unused wire
      Label your unused wire with the provided “C” sticker label. You may need to use a wire stripper to expose at least 1/4 inch of the wire.
      Note: If you have multiple unused wires, then label only one wire and make note of the color here: Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-16Go to your furnace or heating system
      This system is often located in your basement, attic or garage. Bring a flashlight and screwdriver.

    6. Remove cover from furnace or heating system
      Open the heating and cooling system’s cover to find the control board. You should see the same terminal labels that are on your thermostat.
      Note: You may need to unscrew the cover. The control board may be at the top or bottom. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-17

    7. Find the other end of the unused wire
      Locate the bundle of wires that are the same as the ones at your thermostat.
      The unused wire should be the same color as the one near your existing thermostat. See Step 13 for the color you wrote down. Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-18

    8. Connect the unused wire to the C-terminal
      Note: If there are existing wires in the C-terminal, make sure they are still connected to the C-terminal after connecting this wire. Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-19

    9. Close the cover to the furnace or heating system
      Be sure the cover is completely closed. Some systems will not power up if the cover isn’t fully closed.
      You’ve connected the C-wire.
      You will NOT need to use the included C-Wire Adapter. Go back to the wall where you are installing your thermostat and continue to “Installing Your New Thermostat” on the next page.
      Installing Your New Thermostat
      You will need: Level, pencil, drill and a drill bit Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-21

    10. Position wall plate
      Pull open the wall plate that was included with your new thermostat. Insert the bundle of wires through the back of the wall plate.
      Make sure at least 1/4-inch of each wire is exposed for easy insertion into the wire terminals. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-22

    11. Insert recommended wall anchors
      It is recommended that you use the wall anchors included in the box to mount your thermostat.
      You can use the wall plate to mark where you want to place the wall anchors.

      •   * Level the wall plate
      • Mark the location of the wall anchors using a pencil

      • Remove the wall plate

      • Drill anchor holes.
        If your box contains red anchors, drill 7/32” holes.
        If your box contains yellow anchors, drill 3/16” holes.

      • Insert the wall anchors

      • Make sure the anchors are flush with the wall

      • Reposition the wall plate on wall Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-24 Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-25

    12. Determine Correct R-Switch Position and Insert R-wire or wires
      Set the R-switch up or down based on your wiring notes in Step 8. Insert wires into the inner holes of the terminals on the wall plate. The tabs will stay down once the wire is inserted.
      If you have 1 R-Wire (R, RC, RH): Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-26If you have 2 R-Wires (R, RC, RH): Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-27

    13. Connect remaining wires from Step 8
      Push down on the tabs to put the wires into the inner holes of their corresponding terminals on the wall plate (one wire per terminal) until it is firmly in place.
      Gently tug on the wires to verify they are secure.
      Tip: If you need to release the wires again, push down the terminal tabs on the sides of the wall plate. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-28

    14. Close the door and mount the wall plate
      Mount the wall plate using the provided screws. Install all three screws for a secure fit on your wall.
      Tip: Prior to tightening the screws, use a level to ensure the wall plate is level. Honeywell-RCHT9510WFW2001-T9-Smart-
Thermostat-29

    15. Attach your thermostat
      Align the thermostat on the wall plate and firmly snap into place. Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-30Go back to your circuit breaker box.

    16. Turn power back on
      Turn on the switch that controls your heating and cooling system. Honeywell-
RCHT9510WFW2001-T9-Smart-Thermostat-31Go back to your thermostat.

    17. Complete setup on the thermostat
      Remove the protective film and confirm that your thermostat reads “Welcome.”
      If you do not see this, visit HoneywellHome.com/support or call 1-855-733-5465 for more help.

Getting the most from the T9 Smart Thermostat

  • Prioritize Rooms
    Prioritize a specific room or multiple rooms, or let comfort follow your move using built-in motion detection.

  • Control on the Go
    Adjust your thermostat from anywhere using your tablet or smartphone.

  • Save Energy
    With geofencing, you can save money on the most expensive part of your energy bill while you’re away.

  • Simple Installation
    The thermostat automatically programs itself. Just answer a few simple questions and you’ll be up and running in no time.

  • Whole-Home Range
    With up to a 200-foot range, 20 sensors with temperature, humidity, and occupancy detection can connect to your thermostat from throughout your home.
    Range can vary based on home construction, wireless interference, and other factors.

  • Know Your Home Is Safe
    Get customizable alerts on your mobile device such as when the basement is so cold a pipe could burst, or if the baby’s room is getting too hot.

Using your thermostat
The screen will wake up by pressing the center area of the displayed temperature.

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-33

Using Priority
Priority creates an average temperature in your home based on specific rooms. This allows you to prioritize comfort where you want it.
From the Home screen, select MENU, then Priority.

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-34

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-35

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is blank

  • Check circuit breaker and reset if necessary.

Heating or cooling system does not respond

  • Make sure power switch for heating & cooling system is on.
  • Make sure furnace door is closed securely.
  • Make sure the C wire is connected.
  • Make sure the R/Rc jumper is set correctly. See page 11.
  • Press Menu > System Mode > Heat > Done to set the system to Heat mode. Make sure the desired temperature is higher than the indoor temperature.
  • Press Menu > System Mode > Cool > Done to set the system to Cool mode. Make sure the desired temperature is lower than the indoor temperature.
  • Check circuit breaker and reset if necessary.
  • Make sure power switch for heating & cooling system is on.
  • Make sure furnace door is closed securely.
  • Wait 5 minutes for the system to respond.

Temperature settings do not change

  • This thermostat has adjustable minimum and maximum limit settings for heating and cooling. If these settings were not adjusted when setup was done, heat has a setting range of 40-90°F and cool has a range of 50-99°F.

Aux heat runs in cooling

  • For heat pump systems, verify there is not a wire attached to W on the UWP.

Cool runs with a call for heat

  • For heat pump systems, verify there is not a wire attached to W the UWP.

Sensor will not connect

  • Press and hold Connect on the wireless sensor for 15 seconds. The LED will turn Amber. Return to the thermostat menu and press Menu > Devices and Sensors. Follow the on- screen instructions to add the sensor.

CAUTION: ELECTRONIC WASTE NOTICE
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.

2-year limited warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of two (2) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).
If the product is defective,

(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
(ii) call Resideo Customer Care at 1-800-633-3991. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.

Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE TWO YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-633-3991.
The operation of this equipment is subject to the following two conditions: (1) this equipment or device may
not cause harmful interference, and (2) this equipment or device must accept any interference, including interference that may cause undesired operation.

Electrical Ratings

Terminal| Voltage

(50/60Hz)

| Running

Current

---|---|---
W Heating| 20-30 Vac| 0.02-1.0 A
W2 (Aux) Heating| 20-30 Vac| 0.02-1.0 A
E Emergency Heat| 20-30 Vac| 0.02-0.5 A
Y Compressor Stage 1| 20-30 Vac| 0.02-1.0 A
Y2 Compressor Stage 2| 20-30 Vac| 0.02-1.0 A
G Fan| 20-30 Vac| 0.02-0.5 A
O/B Changeover| 20-30 Vac| 0.02-0.5 A
L/A Input| 20-30 Vac| 0.02-0.5 A

NOTE: Not for use with 250, 500, or 750 MV systems.

Apple® HomeKit™ Setup

  1. Touch Menu icon at the bottom of the T9 home screen.
  2. Scroll down and select “Connect HomeKit”.
  3. Use the Apple Home App and select “Add Accessory”. Scan the code shown on your thermostat with your phone.
  4. Follow the instructions on your phone.

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-36

Use of the Works with Apple badge means that an accessory has been designed to work specifically with the technology identified in the badge and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.
AirPlay, iPad, iPad Air, iPad Pro, iPhone and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. HomePod is a trademark of Apple Inc.

Honeywell-RCHT9510WFW2001-T9-Smart-Thermostat-3733-00421ES-05

www.resideo.com

Resideo Technologies Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
33-00421ES—05 M.S. Rev. 10-20 | Printed in United States

© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.
Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals