Honeywell CL201AE Series Portable Evaporative Air Cooler User Manual
- June 13, 2024
- Honeywell
Table of Contents
Honeywell CL201AE Series Portable Evaporative Air Cooler User Manual
PARTS DESCRIPTION
- Control Panel
- Handle
- Louvers
- Power Cord & Plug
- Casters
- Ice Compartment Lid
- Water Level Indicator
- Remote Control
- Water Fill Door
- Drain Plug
WARNING — READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL.
USE & OPERATION
CONTROL PANEL
FUNCTION BUTTONS
POWER
Press the POWER button to turn the unit on. The cooler will start
automatically at medium speed. After a few seconds the speed will switch to
low. To turn the unit off, press the button again.
MODE
Press the MODE button to select your desired wind type: NORMAL – NATURAL –
SLEEP
NORMAL: You can select either High, Medium or Low fan speeds.
NATURAL: The fan speed alternates between High, Medium, Low and Off to
mimic a natural breeze
SLEEP: This mode is for comfort during the night. When the SLEEP mode is
selected, the airflow will randomly vary between High, Medium and Low.
SPEED
Press the SPEED button repeatedly to change the speed between High – Med –
Low.
TIMER
Press the TIMER button until the desired time duration setting is selected.
When the set time has passed, the unit will automatically turn off (unit
remains in Standby mode until power cord is unplugged from electrical socket).
The TIMER function allows you to program the unit for up to 8 hours of use.
FUNCTION BUTTONS (CONTINUED
SWING
Press the SWING button until the SWING indicator light is illuminated on the
control panel. The louvers will begin to move left to right
automatically.Vertical Air Flow – You can manually adjust the louvers to
change vertical air flow.
COOL
Press the COOL button until the COOL indicator light is illuminated on the
control panel. This activates evaporative cooling. The water pump will operate
and you will feel the cooler air after the Honeycomb Cooling Media is
completely wet. When the COOL indicator light is switched OFF, the unit can
still function in a fan only mode (without evaporative cooling
ROOM COOLING AND HUMIDIFYING
In cooling mode, Honeywell Air Coolers provide cool, moist air through the evaporation of water. There is a manual Water Regulator knob located in the ice compartment of the unit. This allows you to adjust the amount of water pumped over the Honeycomb Cooling Media, thus helping to control cooling and humidification levels.
When the Water Regulator is set to MIN, the water pump distributes a minimal amount of water to the Honeycomb Cooling Media. This results in less water evaporation and reduces the cooling effect.
When the Water Regulator is set to MAX, the water pump distributes the maximum amount of water to the Honeycomb Cooling Media. This results in maximum water evaporation and greater cooling performance.
REMOTE CONTROL
POWER: ON / OFF
SPEED: Low / Medium / High
COOL: Controls cooling or fan option
SWING: Controls the motion of the louvers
TIMER: Controls the Timer function for automatic off
MODE: Switch between Normal, Natural & Sleep
NOTE
-
The remote control requires AAA (2 x 1.5V) batteries for replacement.
-
Open the battery compartment at the back of the remote control and insert the batteries inside. Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment. Always point the remote control signal transmitter towards the unit when operating. Make sure
-
that the signal path is not obstructed. Remove the batteries if the unit is not going to be used for an extended period of time.
-
Do not drop the remote control.
Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries. -
Do not mix old and new batteries.
-
Do not recharge the battery.
-
Exhausted batteries are to be removed from the product and safely disposed of as per local regulations.
-
Do not dispose of batteries in fire. Batteries may explode or leak.
WARNING: Caution for ingestion of the small battery. Keep away from children and animals
COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.
FILLING WITH WATER
CAUTION:
Unplug the unit from the electrical power outlet before emptying or refilling
the water tank.
Open the Water Fill Door located on the side of the unit. The Water Level Indicator is located at the front of the unit. Refill the water tank when water level is low. Do not fill water above the “Max.” water level mark to avoid water droplets collecting on the louvers. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure.
Note: If ice is available, you may add ice in the top ice compartment to enhance the cooling performance.
Note: The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system. The water capacity in the tank at the “Max.” indicator level may be lower than the actual water capacity of the air cooler.
WARNING: Do not fill water tank with dirty water or salt water. This can damage the unit and Honeycomb media.
LOW WATER ALARM
The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the indicator light will flash continuously. The unit will automatically pause evaporative cooling.
Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again.
To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty.
Applicable for models this feature only.
If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide.
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the
electrical sock
- Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty.
- Refill the water tank with clean water, up to the maximum level and drain it completely.
- Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
- When the product is not in use, store the unit in a dry place out of direct sunlight.
CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA
- The appliance is supplied with a Carbon Dust Filter* and Honeycomb Cooling Media.
- The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
- Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time.
- The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.
- For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off.
*Removing the Carbon Dust Filter/ Honeycomb Cooling Media
**
- Carefully push down and pull out the rear grill from the cooler.
- Pull out the Carbon Dust Filter* and clean with water as needed.
- Remove all the screws from the Rear Frame and carefully pull it off the air cooler.
- To release the Honeycomb Media, remove the screws securing the Honeycomb on the Rear Frame and slide the Honeycomb out of the frame.
- Replace or clean media with water and a damp cloth as needed.
WARNING: DO NOT operate the Air Cooler when the Rear Grill or Rear Frame is removed from the AirCooler, or if there is a loose-fitting Rear Grill or Rear Frame. Doing so can cause serious injury or dangerous electrical shock.
Costumer Support
Hecho en China
© 2018 JMATEK Limited. Todos los derechos reservados.
La marca Honeywell es usada bajo licencia de Honeywell
International Inc. Honeywell International Inc. no representa
ni garantiza este producto.
Este producto es fabricado por Airtek Int’l Corp. Ltd.
(subsidiaria de JMATEK Limited)
Fabriqué en Chine
© 2018 JMATEK Limited. Tous droits réservés.
La marque déposée Honeywell est utilisée en vertu d’une
licence de Honeywell International inc.
Honeywell International inc. ne fait aucune déclaration et
ne donne aucune garantie à l’égard de ce produit.
Ce produit est fabriqué par Airtek Int’l Corp. ltée
(une filiale de JMATEK Limited).
Made in China
© 2018 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license
from Honeywell International Inc.
Honeywell International Inc. makes no representations or warranties with
respect to this product. This product is manufactured by Airtek Int’l Corp.
Ltd. (subsidiary of JMATEK Ltd.).
JMATEK North America LLC
Mahwah, New Jersey 07495 USA
Email: usinfo@jmatek.com
Web: www.jmatek.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>