KEBA KeContact T10 Payment Terminal User Guide

June 13, 2024
KEBA

KEBA LOGO KeContact T10
Payment Terminal
Safety notes and quick guideKEBA KeContact T10 Payment
Terminal

Information on this document

The operating manual (operation and installation) is part of the product and must be downloaded, read and understood before installation and initial use. The current manuals can be downloaded directly from our homepage: www.keba.com/emobility-downloads
The downloaded manuals must be kept for the entire life of the product. If you require the information in another language, please contact your customer advisor.
In addition to the safety notes in this manual, the applicable safety and accident prevention regulations for the application must be observed.

Safety notes

WARNING!
Risk of death due to electric shock and fire hazard!

  • The device may only be installed and operated in perfect condition.
  • A damaged device must be taken out of commission and repaired or replaced by a qualified and authorized electrician.
  • Repairs may only be made to the device by trained service technicians with replacement parts approved by the manufacturer and checked before installation.
  • The device does not have its own cut-off from the power supply. A suitable cut-off device (e.g. circuit breaker, cut-off switch or equivalent means of disconnection) must be provided as part of the electrical system of the building. To interrupt the power supply, always use the designated cut-off device.
  • The device must be protected by a residual current circuit breaker (at least type A).
  • No unauthorized conversion work or modifications may be done to the device.
  • No markings (such as safety signs, warnings, wire markings, etc.) may be removed from the device.
  • The device must be regularly checked for damage, defects, deterioration and dirt.

When installing the device, the following additional notes must be observed:

  • Installation, commissioning, maintenance or retrofitting of the device must be performed by correctly trained, qualified and authorized electricians who are fully responsible for the compliance with existing standards and installation regulations(1).
  • For installation on hollow walls, at least two mounting screws must be secured to a support element of the wall. Special hollow-wall anchors must be used for other mounting screws. It is particularly important to make sure the substructure has sufficient load-bearing capacity.
  • For the Ethernet connection (LAN), only voltages and circuits are permitted to be connected which have a safe separation from hazardous voltages (for example sufficient insulation).
  • The connection panel is never permitted to be left open unattended. Before leaving the device, the connection panel cover must be mounted.
  • Compensation currents flowing through shielding in extended systems can lead to damage to the interfaces and hazards when working on the data lines. Any measures (such as connecting to a shared distribution board, expanding a TN-S network, etc.) should be discussed with the person responsible for building services. (2)
    (1) Persons who, due to their special training, expertise and experience as well as knowledge of current standards, are able to assess the work performed and the possible hazards.
    (2) Please note that additional overvoltage protection may be required by national regulations.

ATTENTION!
Possible damage to property!

  • Never clean the device with aggressive solvents and cleaning agents, abrasive materials, spray water (garden hose, high-pressure cleaner, etc.) or excessive pressure.

When installing the device, the following additional notes must be observed:

  • During outdoor installation, the connection panel cover must not be opened in unsuitable weather (rain, wind, snow, etc.).
  • The device must be mounted on the wall vertically, without any tilt, on a completely flat wall or floor-mounted column; the back side of the charging station must be completely protected.
  • The mounting holes may be drilled only by an authorized specialist in compliance with the safety regulations. The supply line must not be damaged during this process.
  • When connecting and wiring the device, ensure that the connection area is clean so that no foreign objects (pieces of wire, etc.) get inside the device.
  • The joints between the wall/floor-mounted column and the device must not be sealed with silicone. Water must be able to drain off behind the device.
  • The device must not be used as a climbing aid.

General criteria for the site selection

  • Observe the permissible ambient conditions (see “Technical data” in the operating manual).
  • Take into account the local electrical installation regulations, fire prevention measures and accident prevention regulations as well as emergency routes at this site.
  • The device must not be installed in zones at potential risk of explosion (EX environment); areas with special hazards (flooding, mudslides, avalanches, etc.) must be avoided.
  • Do not install the device in the immediate vicinity of flammable materials.
  • The device may only be installed in stationary applications.
  • Install the device so that it is not in the direct path of people.
  • Do not install the device at locations where it is exposed to ammonia or ammonia gas (e.g. in or at stables).
  • The mounting surface must be sufficiently stable in order to withstand the mechanical forces.
  • Do not install the device at locations where falling objects could damage the device (e.g. hung-up ladders or automobile tires).
  • The device must not be exposed to direct spray water (e.g. neighboring manual car wash facility, high-pressure cleaner, garden hose).
  • If possible, the device should be installed with protection from direct rain and sunlight.
  • Follow the applicable national installation standards and regulations.

Disposal
ATTENTION!
Please observe the regulations regarding disposal of electric appliances and electronic devices.

SIMPLIFIED EU DECLARATION OF CONFORMITY
KEBA Energy Automation GmbH
Reindlstraße 51
4040 Linz
AUSTRIA
Hereby, KEBA declares that the radio equipment type model (1) is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet Address: (2)
(*1)

Variants of the Payment terminal / form designation system (example)

KC – T10 –
I| C
II| G
III| 1
IV| P
V| 0
VI| –| 00
VII|
I| Basic serie| KC-T10| …Device generation (KeContact T10)
II| Payment terminal| C| …CCV
III| Region| G| …Germany
IV| Connectivity| 1| …LAN
V| Payment Provider| P
C| …Pay One
…Concardis
VI| Load management| 0| …not available
VII| Customer options| 00| Options for individual customer versions, not relevant for EU declaration of conformity.

(*2) www.keba.com/emobility-downloads

Technical data

Overvoltage category: III gemäß EN 60664
Protection class: I
Protection type: IP54 (Housing) / IP55 (Payment terminal)
Protection against mechanical impact: IK08
Rated supply voltage: Un = 230 V
Rated current: In = 0.1 A
Line frequency: fn = 50 Hz
Mains forms: TT / TN
Operating temperature: Tamb = -20 °C … +50 °C (without direct sunlight)

Radio communication

| Type| Band| Frequency f [MHz]| EIRP [mW]
---|---|---|---|---
NFC| 13,56 MHz| 13,553 – 13,567| ≤ 0.2
KEBA KeContact T10 Payment Terminal - FIGURE 1| KEBA KeContact T10 Payment Terminal - FIGURE 2
---|---

KEBA LOGO KEBA Energy Automation GmbH
Reindlstraße 51
4040 Linz / Austria