KEBA KeContact S10 Car Charging Station User Guide

June 9, 2024
KEBA

KEBA-LOGO

KEBA KeContact S10 Car Charging Station

Notes on this document

The installation manual is part of the product and must be downloaded, read and understood before installation and initial use. The current manuals can be downloaded directly from our homepage:
www.keba.com/emobility-downloads
The downloaded manuals must be kept for the entire life of the product. In addition to the safety notes in this manual, the applicable safety and accident prevention regulations for the application must be observed.

Safety notes

WARNING!
Risk of electric shock and fire hazard!

  • Installation, commissioning, maintenance or retrofitting of the device must be performed by correctly trained, qualified and authorized electricians (1) who are fully responsible for the compliance with existing standards and installation regulations. Please observe that national regulations may be required. Also note that some countries may require a different triggering characteristic of the residual current circuit breaker (Type B).
  • Do not install or use a damaged device.
  • A damaged device must be taken out of commission and repaired or replaced by a qualified and authorized electrician.
  • Repair of the device is not permitted and may only be carried out by the manufacturer.
  • No unauthorized conversion work or modifications may be made.
  • No markings (such as safety signs, warnings, wire markings, etc.) may be removed.
  • For installation on hollow walls, at least two mounting screws must be secured to a support element of the wall. Special hollow-wall anchors must be used for the other mounting screws. It is particularly important to make sure the substructure has sufficient load-bearing capacity.
  • The X2.1 and X2.2 supply lines must be wired with a cable with the corresponding insulation for 230 V. Other lines in the housing may touch these lines.
    • Persons who, due to their special training, expertise and experience as well as knowledge of current standards, are able to assess the work performed and the possible hazards.

CAUTION!
Possible damage to property!

  • Installation and commissioning must be done in a suitable environment. The device must be protected against rain, snow and dirt. If installed outdoors, the connection panel cover is not permitted to be opened in case of rain, wind or snow.
  • Only vertical installation on a wall is permitted.
  • Do not subject the device to high humidity for a longer period of time.
  • If a cold device is brought into a significantly warmer environment (e.g. after extended transport in a cold environment), condensation moisture may form in the device. Before connecting to the power supply, you must wait until the temperature of the device is the same as the room temperature and the moisture has evaporated again.
  • Do not tighten the mounting screws with force (max. 1.2 Nm).
  • The mounting surface must be completely flat. Warpage of the housing must be prevented.
  • If adjustment is necessary, washers must be used.
  • When connecting and wiring the device, ensure that the connection area is clean so that no foreign objects (pieces of wire, etc.) get inside.
  • Never clean the device with aggressive solvents and cleaning agents, abrasive materials, spray water (garden hose, high-pressure cleaner, etc.) or excessive pressure.

General criteria for the site selection
The following criteria must be taken into account when selecting a location:

  • Take into account the local electrical installation regulations, fire prevention measures and accident prevention regulations as well as emergency routes at this site.
  • The device must not be installed in zones at potential risk of explosion (EX environment).
  • The device may only be installed in stationary applications.
  • Do not install the device at locations where it is exposed to ammonia or ammonia gas (e.g. in or at stables).
  • Do not install the device at locations where falling objects could damage the device (e.g. hung-up ladders or automobile tires).
  • The device must not be exposed to direct spray water (e.g. neighboring manual car wash facility, high-pressure cleaner, garden hose).
  • The device should be protected against direct rain as far as possible to prevent icing, hail damage or similar.
  • If possible, the device should be mounted protected from direct sunlight.
  • Observe the permissible environmental conditions (see “Technical data” in the “Installation manual”).

Disposal
ATTENTION!
Please observe the regulations regarding disposal of electric appliances and electronic devices.

Declaration of conformity

The declaration of conformity can be downloaded directly from our homepage:
www.keba.com/emobility-downloads

Technical Data

Protection class: II IEC 61140
Protection type: IP65 IEC 60529
Protection against mechanical impact: IK08 IEC 62262
Rated supply voltage (Europe): U n = 230/3×230(400) V
Rated current (configurable): I n = 16 A / 32 A
Line frequency: f n = 50 Hz
Mains forms: TT / TN / IT
Operating temperature: Tamb = -85 °C …+50 °C (without direct sunlight)

SCAN CODEKEBA-KeContact-S10-Car-Charging-Station-
FIG1

INSTALLATION

KEBA-KeContact-S10-Car-Charging-Station-FIG2 KEBA-KeContact-S10-Car-Charging-Station-FIG3

KEBA Energy Automation GmbH
Reindlstraße 51
4040 Linz / Austria
www.keba.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals