UNI-T UTi320V Plus Thermal Imager User Manual
- June 12, 2024
- UNI-T
Table of Contents
UNI-T UTi320V Plus Thermal Imager
PREFACE
Thank you for purchasing the new UTi320V+ thermal imager. In order to use this
product safely and correctly, please read this manual thoroughly, especially
the cautions part.
After reading this manual, it is recommended to keep the manual at an easily
accessible place, preferably close to the device, for future reference.
LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and
workmanship within one year from the purchase date. This warranty does not
apply to damages caused by accident, negligence, misuse, modification,
contamination and improper handling. The dealer shall not be entitled to give
any other warranty on behalf of Uni-Trend. If you need warranty service within
the warranty period, please contact your seller directly.
This warranty is the only compensation you can obtain. Uni-Trend will not be
responsible for any special, indirect, incidental or subsequent damage or loss
caused by any reason or speculation. As some areas or countries do not allow
limitations on implied warranties and incidental or subsequent damage, the
above limitation of liability and stipulation may not apply to you.
cautions
-
Use or store the product at specified operating or storage temperatures. Otherwise, the device may be damaged.
-
Do not direct the product at high intensity thermal radiation sources, such as the sun, laser device, spot-welder, etc.
-
Do not knock, toss, or shake the product and accessories.
-
Do not place the battery in a high temperature environment or near high temperature objects. Do not short-circuit the positive and negative electrodes of the battery. Do not place the battery in a humid environment or water.
-
Do not expose the device to dusty or damp environment. When used in an environment with water, avoid water splashing on the product.
-
Do not use dissolved or similar liquids on the product or cables, as it may cause device damage.
-
Please follow the following instructions when wiping the device:
Non-optical surface: If necessary, use a clean and soft cloth to wipe the non- optical surface of the thermal imager.
Optical surface: Do not stain the optical surface of the lens when using the thermal imager. Be especially careful not to touch the lens with hands, as sweat from hands will leave marks on the lens glass and may erode the optical coating layer on the glass surface. When the optical surface is stained, carefully wipe it with a special lens paper. -
When using the device, please try to keep it stable and avoid violent shaking.
-
Please close the lens cover and put the product and its accessories into the carrying box when it is not used.
-
Please do not disassemble the device to avoid product damage and loss of warranty rights.
-
Due to different batches, the materials and details of actual products may be slightly different from the graphic information. Please refer to the goods received.
-
The experimental data in the manual are theoretical values and all from Uni-Trend’s internal laboratories, for reference only. Customers cannot use them as bases for placing orders. If users have any questions, please contact customer service.
-
When the temperature is close to the scale switching critical point (about 150’C), due to the sensor’s own factors, the temperature measurement accuracy may exceed +/-2%, which is normal.
Specifications
PC analysis software| (real-time image, photo download, real-time oontrol and
analysis)
---|---
Smartphone APP| iOS, Android
LED flashlight| (two LEDs, white light)
Image modes| Thermal, digital, T-Mix fusion.PIP
Image capture mode| Photo capture, time-lapse photography, video recording
Image saving format| JPG
QR code scanning|
Audio| Built-in speaker and microphone
Touch screen|
Certificates| CE,FCC,UKCA,ROHS
Operating temperature| -10°C-50°C (14°F-122°F)
Storage temperature| -20°C-60°C (-4°F-140°F)
Operating humidity| 10%-95%RH (non-condensing)
Battery| Detachable Li-ion battery pack with 5200mAh (UT-M17)
Auto power off| OFF,5min,10min,20min,30min.45min,60min.90min
Operating time| > 4h
Charging time| < 5h
Charging voltage/current| 5V/2A
Image storage| Micro SD card
IP rating| IP54
Drop proof| 2m
Altitude| < 2000m (indoor use)
Structure
LCD Indicators/Icons
Power on/off
Long press the Power button for 5s to turn on the thermal imager (it needs 30
minutes warm-up time when the device is just turned on or not used for a long
time, or the measurement environment changes). Long press the Power button for
3s, “Shutdown?” will show on the screen. Select “OK” to turn off the thermal
imager. Long press the Power button for 8s to power off directly. When the
battery is low, a low battery indicator will show on the screen, which means
the thermal imager should be turned off and the battery should be charged.
When the thermal imager is in low battery status for a long time, it will
automatically shut down.
Menu Bar
- Press the SET button in the main interface or tap the menu bar icon to open the main menu.
- Press the Left/Right and SET buttons or tap a submenu icon to open the selected submenu.
- In the submenu, press the Left/Right button or tap its icon to select an option.
- Press the SET button or tap the icon to confirm and save the selection. The thermal imager returns to the main interface.
Submenu
Markup | Display/hide the center spot, Hi/Lo spot and the value |
---|---|
Image | Select the thermal, digital, fusion or PIP mode or add the QR code |
Palette
| Switch between lronbow, Rainbow, Black Hot, White Hot, Red Hot, Lava,
Rainbow HC
Measure| Add point, line, rectangle or circle for temperature analysis
Isotherm
|
Switch between Auto, Ratio, Below, Above, Section or Manual
Settings| System settings
PIP
After the PIP mode is enabled, users can press the Left/Right and SET buttons
or tap the screen to select Move, Stretch or Mix to change the PIP position
and size and to adjust the fusion ratio.
QR Code
Users can manually input or scan the QR code. Select “Cancel” to return to the
main interface. After a QR code is input or scanned, it can be saved to a
classified folder. After saving, a QR code symbol will be displayed in the
upper right corner of the main interface. At this time, all the photos/videos
taken will be marked with this OR code and these photos/ videos will be saved
to the corresponding classified folder. Enter the QR code interface again to
cancel the current QR code.
Measure (On Screen Analyzer)
In the “Measure” submenu, press the Left/Right and SET buttons or tap the
screen to add an analysis object (point, line, rectangle or circle), choose an
object (this function can only be used if an object is added), clear or
preset.
After adding an analysis object, a submenu will appear. The optional functions in the submenu are choose, move, stretch (this function cannot be applied to point objects), difference (point objects can only be compared with point objects; the comparison information will be displayed on the right side), delete (delete the selected object). The temperature information of the added object will be displayed on the left. When a line object is selected, its temperature change graph will be displayed in the lower left comer.
When the “Clear” function is enabled, all the added analysis objects will be cleared. When the “Preset” function is enabled, a prompt “Save tool” will pop up. Select “OK” to save the current object. The preset tool can be used directly next time. If there is no analysis object in the main interface, enable the “Preset” function, and a prompt “Read tool” will pop up. Select “OK”, and the preset tool saved last time will be added to the main interface.
Note
The maximum number of point objects that can be added is 5 (line: 1;
rectangle: 3; circle: 3). The total number of objects added cannot exceed 6.
When it exceeds the specified number, a prompt “XX outnumber” will pop up.
Image Browsing and Editing
In the main interface, press the Image browsing button to enter the multimedia
browsing interface. Press the Up/Down and SET buttons or tap the screen to
open All photos/videos or other folders. Press the direction and SET buttons
or tap to browse a photo or video. Press the Left/Right button or slide the
screen to switch between photos/videos.
When browsing a photo or video:
- Press the SET button or tap the screen to open the submenu.
- Press the Left/Right and SET buttons or tap to select Info/Notes/Edit/QR code/ Delete.
Info
| Create date, modified date, emissivity, HVGA (infrared resolution), QR code
(the classified folder where the photo/video is saved}, distance (photos
only}, notes (text/voice)
---|---
Notes| Add text and voice notes to photos/videos (displayed in Info)
Edit (photos only)
| Perform Markup/Image/ Palette/Measure/ Isotherm/Graffiti function on photos
Play (videos only}| Play or pause videos
QR code| Add QR code to classify photos/videos
Delete| Delete the current photo/video
Edit
After editing a photo, press the direction and SET buttons or tap to restore
the photo to its initial state (graffiti cannot be cleared in this way).
Press the Return button after editing a photo, and a prompt “Exit?” will pop up. Select “Exit” to exit the editing interface. Select “Save” and a prompt “Cover?” will pop up. Select “Cover”, the original photo will be changed and saved. Select “New”, the original photo will not be changed and a new photo will be saved.
QR Code
When the QR code function is enabled, users can add existing QR code to
classify photos/videos, delete the QR code of photos/videos or add a new QR
code. QR codes added here are temporary and will not be saved to the existing
QR code classified folders. The classified folders can only be modified in the
Settings.
Digital Zoom
In the main interface, press the Up button to zoom in the screen. The current
magnification is displayed in the upper right comer of the screen. The
magnification steps through 1X, 2X, 4X and 1X.
Settings
After entering the Settings interface, press the Up/Down and SET buttons or
tap the screen to select a setting item.
Camera mode | Single show VIDEO /Time-lapse (10s-1000s) |
---|---|
Units | Temperature: ·c, K, “F; Distance: m, ft |
Parameter | Adjust the emissivity (refer to the emissivity table) and object |
distance (manual/auto)
Hi/Lo alert| Hi/Lo/LED/audible alert
QR code| Change the name of classified folders and reset OR codes
Language| Switch between English/Chinese
Date & Time| Modify time-format/date/time
Wi-Fi| Turn on/off the hotspot, modify hotspot information when it is on
USB mode| USB storage/USS projection
Brightness| Adjust the brightness (1-100)
Volume| Adjust the volume (1-100)
Laser distance measure| Laser distance measure mode: single/continue
measurement
Shutdown
(auto power off)
| Off/5 min/10 min/20 min/30 min/45 min/60 min/90 min
Factory reset| Restore the factory settings
Format| Format the SD Card
About
| Display product model, HVGA (infrared resolution), SWV (software version), HWV {hardware version), SYSV (system version), SD card capacity
Hi/Lo alert
After entering the settings interface, press the Up/Down and SET buttons or
tap the screen to select “Hi/Lo alert”. In the submenu, users can select
Hi/Lo/LED/audible alert. When Hi/ Lo alert is enabled, press the Up/Down and
SET buttons or slide the screen to adjust the Hi/Lo value. When the measured
temperature exceeds the Hi value, a red triangle will pop up in the main
interface. When the measured temperature is lower than the Lo value, a green
inverted triangle will pop up. (If the LED alert is enabled, the alerts will
be accompanied by flashing lights. If the audible alert is enabled, a sound
will be emitted.)
Wi-Fi
After entering the settings interface, press the Up/Down and SET buttons or
tap the screen to select “Wi-Fi”. Press the SET button or tap the screen to
turn on the Wi-Fi Hotspot. Press the Up/Down and SET buttons or tap to change
the AP bands, ID or password.
Laser Distance Measure
In the main interface, press the “Laser distance measure” button to take
measurements. If “Single” is selected in the settings interface, press and
hold the “Laser distance measure” button until the distance value appears.
Release the button to exit. If “Continue” is selected in the settings
interface, long press the “Laser distance measure” button until the distance
value appears. Release the button and move the thermal imager to take
continuous measurements. Press the button again to exit the measurement.
SD Card
The device can be inserted into a Micro SD card to store images. To avoid
affecting the device operating speed, please copy the backup data regularly
and clean up the SD card in time. Do not insert or remove the SD card
repeatedly; otherwise the data in it may be abnormal. If the SD card is
removed when users are viewing or editing images, a prompt “SD lost” will pop
up.
Maintenance
Use a wet cloth or weak soap solution to clean the outer housing of the
device. Do not use abradant, isopropyl alcohol or solvents to clean the
housing or lens.
Notes
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received .including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Product label
Emissivity Table
Material | Emissivity | Material | Emissivity |
---|---|---|---|
Wood | 0.85 | Black paper | 0.86 |
Water | 0.96 | Polycarbonate | 0.8 |
Brick | 0.75 | Concrete | 0.97 |
Stainless steel | 0.14 | Copper oxide | 0.78 |
Tape | 0.96 | Cast iron | 0.81 |
Aluminum plate | 0.09 | Rust | 0.8 |
Copper plate | 0.06 | Gypsum | 0.75 |
Black aluminum | 0.95 | Oil paint | 0.9 |
Human skin | 0.98 | Rubber | 0.95 |
Asphalt | 0.96 | Soil | 0.93 |
PVC plastic | 0.93 |
The contents of this manual are subject to change without notice.
UNl-“‘I’:UNI-TRENDTECHNDLDGV (CHINA) CD.,LTD.
No. 6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City, Guangdong Province, China
Read User Manual Online (PDF format)