ESBE GRB300 Manifolds for 2 Circulation Units Instruction Manual
- June 4, 2024
- ESBE
Table of Contents
- ESBE GRB300 Manifolds for 2 Circulation Units
- Function
- Cabling & Dimensions
- Electric installation
- Mounting position actuator/controller
- **Commissioning
- Display
- WILO Faults, Causes and Remedies
- Expose application info using leaflet
- Dimensioning, Pump Capacity diagram Series GRB301
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ESBE GRB300 Manifolds for 2 Circulation Units
Function
Cabling & Dimensions
Electric installation
-
Remove knob Disassembly insulation
-
Pull up insulation 7mm Remove
-
Assembling on wall
Adjust wallbracket -
Fit supply pipes
-
Assemble insulation
-
Assemble actuator/controller
Mounting position actuator/controller
Mounting position
**Commissioning
**
Commissioning actuator/controller
Display
Venting
Manual restart
WILO Faults, Causes and Remedies
LED Indicator | Faults | Causes | Remedies |
---|---|---|---|
Pump is not running although the power supply is switched on | Electrical fuse | ||
defective | Check fuses | ||
Pump has no voltage | Resolve the power interruption | ||
Pump making noises | Cavitation due to insufficient suc- tion pressure |
Increase the system pressure within the permissible range
Check the delivery head and set it to a lower head if necessary
Building does not get warm| Thermal output of the heating surfaces is too low|
Increase setpoint
Set control mode to Δp-c
Warning signals is indicated by the LED display. Fault signal LED does
not light up.
E07| Generator operation| Water is flowing through the pump hydraulics, but
pump has no mains voltage| Check mains voltage
E11| Dry run| Air in the pump| Check volumetric flow rate/water pressure
E21| Overload| Sluggish motor, pump is opera- ted outside of its
specifications (e.g. high module temperature). The speed is lower than during
normal operation.| Check the ambient conditions
Fault signals is indicated by the LED display. Fault signal
LED lights up red.
E04| Undervoltage| Power supply too low on mains side| Check mains voltage
E05| Overvoltage| Power supply too high on mains side| Check mains voltage
E10| Blocking| Rotor blocked| Activate manual restart or con- tact customer
service
E23| Short-circuit| Motor current too high| Request customer service
E25| Contacting/ winding| Winding defective| Request customer service
E30| Excessive temperature of module| Module interior too warm| Check
conditions of use
E36| Module defective| Electronics defective| Request customer service