miele PWT 6089 EL Washer Dryer Stack Installation Guide
- June 12, 2024
- Miele
Table of Contents
Installation plan
Washer-dryer stack PWT 6089 EL (Electrically Heated)
M.-Nr. 10 167 290 / 00
PWT 6089 EL Washer Dryer Stack
Please have the model and serial number of your machine available when
contacting Technical Service.
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
www.mieleusa.com/professional
prosales@mieleusa.com
Technical Service & Support
Phone: 800-991-9380
proservice@mieleusa.com
**** Manufacturer | Fabricant : Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gütersloh, Germany | Allemagne
Technical datasheet
Washer/Dryer stack:
Heating:
PWT 6089 LP (Drain pump)
Electric (EL)
Legend:
Abbreviations in bold type: Connection required
Abbreviations in circle with dashes: Connection optional or required depending
on model version
Options/accessoires:
| Dispensing pump| External dispensing pumps (2 or 4 head pump):
Voltage (external power supply required)
Fusing
Supplied with supply cable and plug
Pump installation may only be performed by Miele Service.| | 120V
15A
NEMA 5-15
---|---|---|---|---
Machine connections:
| Electrical connection
EL1
| Standard voltage (2 AC 208V/220-240V 60Hz)|
|
---|---|---|---|---
NOTE: Electrical connection depending on version ordered.
Washer (EL1) – 2 AC 208V/220-240V 60Hz
Voltage Frequency| V
Hz| 2 AC 208 / 220-240
60
Rated load| kW| 4 / 4.4 – 5.2
Fuse rating| A| 2 x 30
Length of supply lead| 78“| 2000 mm
Supply lead with plug| | NEMA L6-30P
EL2
| Dryer (EL2) – 2AC 208V 60Hz
Voltage Frequency| V
Hz| 2 AC 208
60
Rated load| kW| 4.84
Fuse rating| A| 2 x 30
Length of supply lead| 78“| 2000 mm
Supply lead with plug| | NEMA L6-30P
EL2
| Dryer (EL2) – 2AC 220-240V 60Hz
Voltage Frequency| V
Hz| 2 AC 220-240
60
Rated load| kW| 5.7
Fuse rating| A| 2 x 30
Length of supply lead| 78“| 2000 mm
Supply lead with plug| | NEMA L6-30P
| |
Electrical connection must be in full compliance with national regulations and
guidelines and with relevant local codes. Similarly, relevant regulations
issued by power utilities, occupational safety authorities and insurance
companies as well as good installation practices should be observed
throughout.
Connection to the electrical supply should only be performed by qualified and
properly trained persons.
Connection using a multi-pole wall lockable socket(s) in compliance with
IEC/EN 60309 and IEC/EN 60947 is recommended in order to simplify electrical
tests. If machines are hard-wired, a multi-pole main switch must be provided
on site. Switches with a contact gap of more than 3 mm can be used. These
include switches, fuses and contactors (IEC/EN 60947). A wall socket or
electrical isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment or checks on the
protective conductor, including determination of correct fuse rating, should
only be performed by a properly trained electrician.
If necessary, equipotential bonding must be provided in accordance with all
appropriate national and local regulations.
|
NT
| Electrical isolator| Both washer-dryer stack connections must be
disengaged by a common electrical disconnect device that switches off all
poles in accordance with IEC 60947-1 [Q1].
The electrical isolator [Q1] and plug connections [EL1, EL2] must be
located in the immediate vicinity of the machine. Both must be visible,
accessible and within easy reach.
If the electrical isolator [Q1] is not in full view of a person performing
maintenance work on the machine at all times, the electrical isolator must be
fitted with a lock.
Installation proposals:
---|---|---
KW| Cold water (Soft water)| Min. flow pressure Max. pressure Max.
throughput
On-site connection thread Length of connection hose (supplied: 1 connection
hose)
Hourly water demand (average for 60°C program) for standard connection (with
hot and cold water)
If hot water supply is not available add hot water demand to cold water
demand.| 14.5 psi 145 psi
2.9 gal/min
¾” external thread 61“
approx. 18.5 gal/h| 100 kPa
1000 kPa
11 l/min
¾” external thread 1550 mm
approx. 70 l/h
---|---|---|---|---
WW| Warm water (Soft water)| Max. temperature Min. flow pressure Max.
pressure Max. throughput
On-site connection thread Length of connection hose (supplied: 1 connection
hose)
Hourly water demand (average for 140°F / 60°C program)
Machine can be connected to a hot water supply line with a temperature of
158°F (70°C) to max.185°F (85°C). This requires a separate inlet hose. This
additional inlet hose is available from Miele. The machine must also be
reprogrammed by Miele Service.
If hot water is not available, connect hot water hose to cold water valve!
| 158°F
14.5 psi 145 psi
2.9 gal/min
¾” external thread 61“
approx. 18.5 gal/hr| 70°C
100 kPa
1000 kPa
11 l/min
¾” external thread 1550 mm
approx. 70 l/h
LP| Drain pump| Max. temperature
Drain hose(int. diameter)
On-site hose connector for drain hose (int. diameter x length)
Max. transient throughput
Drain pump head height (from floor level)
Vented drainage required. If ventilation is insufficient, Miele installation
kit, Mat. no. 05238090. Drain manifolds serving several machines must be of
sufficient cross-section.| 158°F
7/8“
7/8“ x 1 3/16“
6.9 l/min 39 3/8“| 70°C
22 [DN 22] mm
22 × 30 mm
26 l/min
1000 mm
AL| Vented| Nominal air throughput in vented mode Max. permissible
pressure loss
Waste air/gas temperature, max. Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Miele adapter, Mat. no. 6595070 (int. diameter 100 mm) for flexible aluminum
ducting and adapter, Mat. no. 915051, (ext. diameter 110 mm) for connection to
standard heat- resistant plastic pipes supplied.
As relative humidity inside the vent ducting can be as high as 100%, suitable
measures must be taken to prevent a backflow of condensate into the machine.|
188 cfm
0.06 psi 176°F 4”
4”| 320 m³/h
420 Pa
80°C
100 mm
100 mm
ZL| Air intake| Standard connection:
=> Air intake from installation site Min. air intake cross-section (to prevent
draughts in room)
A sufficient supply of fresh air should be ensured to replace the air
extracted.| 37 in2| 237 cm²
B| Fittings (supplied)| 4 × clamps
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided on site.| 1/4“
x 2“
5/16“ x 1 9/16“| 6 × 50 mm
8 × 40 mm
| Machine data| Unit width| 27 1/2“| 700 mm
---|---|---|---|---
Unit depth| 30“| 752 mm
Unit height| 76“| 1930 mm
Casing width| 27 1/4“| 692 mm
Casing depth| 27 1/4“| 690 mm
Minimum width of delivery access to installation site| 28 3/8“| 720 mm
Recommended rear wall gap| 43 5/16“| 1100 mm
Minimum rear wall gap| 35 7/16“| 900 mm
Recommended rear wall gap ensures sufficient space for maintenance and
servicing| |
Net weight| 463 lbs| 210 kg
Dynamic floor load, max.| 3600 N| 3600 N
Static floor load, max.| 2850 N| 2850 N
Dynamic load, max.| 750 N| 750 N
Drum frequency, max.| 22 Hz| 22 Hz
Average heat dissipation| 2830 BTU/hr| 0.83 kWh
(dependent on ambient room temperature and program selected)| |
Sound pressure (re 20 mPA), workplace-related (at distance of 3’ 3” / 1 m and
height of 5’3” / 1.6 m)| <70dB(A)| <70dB(A)
Installation should only be carried out by authorized installers in accordance
with valid regulations! Observe installation instructions when installing
machine! All rights reserved!
Technical datasheet: PWT 6089 EL
Date: Feb-2015
Documents / Resources
|
miele PWT 6089 EL Washer Dryer
Stack
[pdf] Installation Guide
PWT 6089 EL, PWT 6089 EL Washer Dryer Stack, Washer Dryer Stack, Dryer Stack,
Stack
---|---