Product Information:

Feature Value
Angular travel Limited Stop
Speed N/A
Load Rating N/A
Duty Cycle N/A
Input Voltage N/A
Power Consumption N/A
Normal Operating Current N/A
Cable Requirement N/A
Operating Temperature N/A
Construction N/A
Finish N/A
Dimensions N/A
Weight N/A

Product Usage Instructions

  1. Installation:
    • The unit is intended to be mounted on a Wall Mount.
    • Installation of the pan and tilt drive to the wall mount requires a stainless steel 1/4-20 screw supplied with the wall mount.
    • Note the ribs on the underside of the unit base engage slots in the mount. This allows the positioning of the unit in any of four directions with respect to the wall mount.
    • Secure unit to the wall mount using the screw from the underside of the wall mount into the unit and tighten.
  2. Wiring of Unit:
    • Fabricate the interconnecting cable in accordance with Figure 1 for proper operation.
    • POWER (red)
    • COMMON (black)
    • TILT DOWN (yellow)
    • TILT UP (blue)
    • PAN RIGHT (green)
    • PAN LEFT (white)
  3. Inverted Mounting:
    • When the unit is mounted in the inverted position, the left-right directions are reversed for manual operation.
    • This must be corrected when wiring the cable between the control unit and the pan and tilt drive. Simply reverse leads going to terminals 3 and 4.
  4. Adjusting Limit Stops:
    • After cable is installed and unit has been mounted, proceed as follows:
    • Plug control unit into AC 24V source. Be sure auto switch is in the OFF position.
    • To adjust pan limit stops (see Figure 2), loosen screws securing both stops (1) and (3) to unit. Slide stops around unit to desired locations and secure by tightening screws.
    • To adjust tilt limit stops (see Figure 2) located in each end plate, remove two screws securing each end cap to unit. Loosen and adjust tilt limit stop screws for desired tilt limit position.
    • Tighten limit stop screws and reinstall each end cap to unit and secure with two screws.
  5. Maintenance:
    • This pan and tilt drive requires no lubrication or maintenance for the life of the unit.
    • If the unit fails to function, turn it off and check the fuse on the control unit. Replacement fuse values are given in the instructions supplied with the control unit.

INSTALLATION

The unit is intended to be mounted on a Wall Mount. Installation of the pan and tilt drive to the wall mount requires a stainless steel 1/4-20 screw supplied with the wall mount. Note the ribs on the underside of the unit base engage slots in the mount. This allows the positioning of the unit in any of four directions with respect to the wall mount. Secure the unit to the wall mount using a screw from the underside of the wall mount into unit and tighten it.

WIRING OF UNIT

Fabricate the interconnecting cable in accordance with Figure 1. for proper operation.

INVERTED MOUNTING
When the unit is mounted in the inverted position, the left-right directions are reversed for manual operation. This must be corrected when wiring the cable between the control unit and the pan and tilt drive. Simply reverse leads going to terminals 3 and 4.

ADJUSTING LIMIT STOPS
After cable is installed and unit has been mounted, proceed as follows:

  1. Plug control unit into AC 24V source. Be sure auto switch is in the OFF position.

  2. To adjust pan limit stops (see Figure 2), loosen screws securing both stops (1) and (3) to unit. Slide stops around unit to desired locations and secures by tightening screws.

  3. To adjust tilt limit stops (see Figure 2) located in each end plate, remove two screws securing each end cap to unit. Loosen and adjust tilt limit stop screws for desired tilt limit position. Tighten limit stop screws and
    reinstall each end caps to unit and secure with two screws.

  4. Right Pan Limit Stop

  5. Limit-Switch Actuator

  6. Left Pan Limit Stop

  7. Tilt Limit Stop Screw

  8. Camera Mounting Plate

  9. Screw

  10. Down Limit Stop

  11. 4-conductor cable for video signal

  12. Connection to control (VSCP1)

  13. Video Output

Specifications

  • Tilt control: Push Button, UP/DOWN
  • Pan control: Push Button, LEFT/RIGHT
  • Power control: Slide Switch MAN/OFF/AUTO
  • Input Voltage: AC 220-230V
  • Output Voltage to Scanner: AC 24V
  • Temperature Operating : -10°C to +60°C
  • Connector: Screw Terminal-Detachable
  • Construction: Steel, Off-White Textured
  • Dimensions : 212 x 218 x 45mm
  • Weight: 1.2Kgvelleman-VISP1-PAN-or-TILT-Unit-FIG- \(4\)

MAINTENANCE

This pan and tilt drive requires no lubrication or maintenance for the life of the unit. If the unit fails to function, turn it off and check the fuse on the control unit. Replacement fuse values are given in the instructions supplied with the control unit.

SPECIFICATIONS

  • Angular travel : Pan : 350° / Tilt : ± 75°
  • Limited Stop: Externally adjustable
  • Speed : Pan: 6° / second
  • Tilt: 4° / second
  • Load Rating: Pan: 7 kg / Tilt: 5 kg
  • Duty Cycle: Pan: Continuous
  • Tilt: intermittent
  • Input Voltage: AC 24V
  • Power Consumption: 6W
  • Normal Operating Current: 24V-200mA
  • Cable Requirement: Six-conductor, unshielded
  • Operating Temperature : -5°C to + 60°C
  • Construction: Aluminium and plastic
  • Finish: Off-white baked enamel finish
  • Dimensions : 150 x 160 x 200mm
  • Weight: 2.3 kg

Feature

velleman-VISP1-PAN-or-TILT-Unit-FIG- \(3\)

  • Auto on : LED – Green
  •  Bypass on : LED – Red
  • Non-light during off
  • Special screw terminal-detachable connector easy for installation

Operations

velleman-VISP1-PAN-or-TILT-Unit-FIG- \(1\)

FRONT PANEL
Power: Push the rocker switch to “AUTO”, and the Green LED will illuminate. Scanner automatic left and right adjust. Push the rocker switch to “MAN”, the Red LED will illuminate.

  1. The scanner adjusts manually.
  2. Nonlight during “OFF”
  3. UP AND DOWN: Paddle switch, UP/DOWN
  4. LEFT AND RIGHT: Paddle switch, LEFT/RIGHT

BACK PANEL

  1. AC POWER: Terminal block no. 1 point
  2. LEFT: Terminal block no. 2 point
  3. RIGHT: Terminal block no. 3 point
  4. COM: Terminal block no. 4 point
  5. UP: Terminal block no. 5 point
  6.  DOWN: Terminal block no. 6 point