HTC PVB 805 Vibration Meter User Manual
- June 12, 2024
- HTC
Table of Contents
HTC PVB 805 Vibration Meter
Product Information
- Product Name: Vibration Meter
- Model: PVB 805
- User Manual: Included
- This Vibration Meter is designed for measuring acceleration, velocity, and displacement in various applications. It comes with different probes for different purposes, allowing for accurate and reliable testing.
- The meter has a sensor, LCD display, keys for operation, LED light, and a battery cover. It operates on 2 AAA batteries and has a long working life. It has a wide frequency range for measuring vibrations and a large storage capacity for saving data. The meter is compact and lightweight, making it easy to carry and use.
Product Usage Instructions
Before Operation
Packing Details:
- The Meter: 1 unit
- 1.5V AAA Battery: 2 units
- User Manual: 1 unit
- Short Probe: 1 unit
- Long Probe: 1 unit
- Lifting Rope: 1 unit
Please check the accessories according to the packing list. If anything is missing, contact the local agent or store immediately.
Preparation
Battery Installation:
- Open the battery cover.
- Insert 2 AAA batteries, ensuring correct polarity.
- Close the battery cover.
Probe Installation:
Choose the appropriate probe for the desired purpose:
- Short Probe: Used for regular testing and provides reliable results.
- Hand Spin Probe:
- Long Probe:
Operating Instructions
Power on/off:
To power on, press the Power button. To power off, press and hold the Power button.
Measure and Data-locking:
Press the Power button to start measuring. Press it firmly to lock the measured data.
Acceleration Measurement in Low Frequency:
Use the appropriate probe for low-frequency acceleration measurement. Refer to the user manual for specific instructions.
Acceleration Measurement in High Frequency:
Use the appropriate probe for high-frequency acceleration measurement. Refer to the user manual for specific instructions.
Velocity Measuring:
Refer to the user manual for instructions on velocity measuring.
Displacement Measuring:
Refer to the user manual for instructions on displacement measuring.
Full Display:
The meter has a full display mode that shows all measurement parameters simultaneously. Refer to the user manual for instructions on activating this mode.
Menu:
- Press the Menu button to access different options and settings.
- Use the Up and Down buttons to navigate through the menu. Refer to the user manual for detailed instructions.
View Records:
Access the stored records on the meter. Refer to the user manual for
instructions on viewing records.
Auto Power off Time:
Adjust the auto power off time setting. Refer to the user manual for
instructions on changing this setting.
Information:
Access additional information and settings. Refer to the user manual for
instructions on accessing this information.
Others
General Problems:
Refer to the user manual for troubleshooting common issues with the meter.
Maintenance
Follow the maintenance guidelines provided in the user manual to ensure
proper functioning and longevity of the meter.
Appendix:
Refer to the appendix section of the user manual for additional information
and resources.
User Instructions
- This manual introduces application method, attentions and other items about the product in detail. Please read it intently to operate the meter efficiently.
- Do not use it inflammable, explosive circumstance.
- Do not throw away the electrical waste with normal household waste, please dispose it by national or local related law and regulations.
- If there are any quality problems or any doubts about how to operate, please contact the retailer or us, we will solve it as soon as possible.
Before Operation
Packing Details
Please check your accessories according to the below list. If there is
anything missing, please contact the local agent or stores immediately.
No. | Description | Unit | Quantity | Remark |
---|---|---|---|---|
1 | The Meter | PC | 1 | |
2 | 1.5V AAA Battery | PC | 2 | |
3 | User Manual | PC | 1 | |
4 | Short Probe | PC | 1 | |
5 | Long Probe | PC | 1 | |
6 | Lifting Rope | PC | 1 |
Brief Introduction
Vibration test is a crucial method of monitoring device condition and
diagnosing malfunction. The utilization of handheld vibration meter improves
the production safety, product quality and production efficiency. The
application gets piezoelectric accelerated sensor which turns vibration signal
into electrical signal, the device works by processing and analysing the input
signal, and shows vibration acceleration, velocity, displacement value on
screen. It is used widely in machine manufacturing, electric power, metallurgy
and vehicle manufacturing fields.
Parts Name
- Sensor
- LCD
- Keys
- LED
- Battery Cover
Specifications
Items | PVB 805 |
---|---|
sensor | piezoelectric accelerated sensor |
acceleration measurement range | 0.1~199.9m/s2(peak value) |
velocity measurement range | 0.1~199.9mm/s(real-time valid value) |
displacement measurement range | 0.001~1.999mm(peak-peak value) |
accuracy | ±(5%+2dgts) |
low frequency acceleration measuring frequency range | 10Hz~1KHz |
high frequency acceleration measuring frequency range | 1KHz~10KHz |
velocity measuring frequency range | 10Hz~1KHz |
displacement measuring frequency range | 10Hz~500Hz |
storage capacity | 200 sets |
data refresh time | 500ms |
power | 2*1.5V AAA battery |
battery working life | beyond four hours without breaks |
working temperature | 0°C~50°C |
working humidity | 20%RH~80%RH |
storage temperature | -20°C~60°C |
storage humidity | 20%RH~80%RH |
dimension | 1765425mm |
net weight | 121g |
height above sea level | <2000m |
Attentions
- Do not use it in high temperature and humidity environment.
- Do not use it nearing corrosive materials.
- Do not use it if it could be splashed.
- Do not use it in chemical gas condition.
Preparation
Battery Installation
Open the cover, put 2*1.5V AAA batteries in according to right polarity.
Probe Installation
There are different probes for different purposes
(tips: different probe corresponds with different purposes for different
meets)
- Short probe is utilized in common for regular testing, and the result is reliable.
- Long probe is for some places where short probe can not reach , which is good for regular testing. (However, it is not suggested to use this longer probe for testing in high frequency acceleration testing, because of the quick decreasing of high frequency.)
- No probes, it’s crucial that the head is contacted well with the measuring point for the best frequency response result which is in range of 10Hz~10KHz.
General Regulation
In frequency range of 10Hz~1KHz, short and long probes are reliable for
displacement, velocity and acceleration, but it is suggested to use short
probe for high frequency acceleration testing. The bearing stress on sensor
should be even, and do not impact the sensor to avoid split of transistor.
Operating Instructions
Power on/off
Short press to turn it on, long press to shut it down.
Measure and Data-locking
Press firmly to test, loose it, the reading remains same.
Attention:
- The stress acted on the tested object is 0.5~1.0kg
- The probe should be vertical with the surface of tested object for accurate result.
For Example:
Acceleration Measurement in Low Frequency
The applicable frequency range is 10Hz~1KHz. Operations as follows:
- Short press SET
- Choose Acceleration/Low Frequency by UP/DOWN
- Short press SET to enter this testing mode or press BACK to return
Acceleration Measurement in High Frequency
The applicable frequency range is 1KHz~10KHz. Operations as follows:
- Short press SET
- Choose Acceleration/High Frequency by UP/DOWN
- Short press SET to enter this testing mode or press BACK to return
Velocity Measuring
The applicable frequency range is 10Hz~1KHz. Operations as follows:
- Short press SET
- Choose Velocity by UP/DOWN
- Short press SET to enter this testing mode or press BACK to return
Displacement Measuring
The applicable frequency range is 10Hz~500Hz. Operations as follows:
- Short press SET
- Choose Displacement by UP/DOWN
- Short press SET to enter this testing mode or press BACK to return
Full Display
Full Display means there are three results, low frequency acceleration,
velocity and displacement, show on the screen at the same time.. Operations as
follows:
- Short press SET
- Choose Full Screen by UP/DOWN
- Short press SET to enter this testing mode or press BACK to return
Menu
It is supported with three options: record, auto-off and information in the
menu. Operations as below:
- Short press SET
- Choose Menu by UP/DOWN
- Short press SET to enter this testing mode or press BACK to return
View Records
User can check the historical data by view records. Operations as below:
- Select RECORD by UP/DOWN, press SET to go into the record page
- Turn page by UP/DOWN
- Long press OFF to delete all records in current page
- Short press SET to enter the record page
- Choose record number by UP/DOWN
- Short press SET to check the record details or press BACK to return
Auto Power off Time
There are four options for auto power off time. Operation as follows:
- Choose Power off by UP/DOWN.
- Select off time by press UP/DOWN, short press SET to save the setting. Then short press BACK to return.
Information
It shows Basic parameters in this page. Operations as follows:
- Choose Information by UP/DOWN.
- Short press BACK to return.
Auxiliary Functions
- LED Light: Short press to turn it on/off. This operation can only be done in full display measuring page.
- Screen Rotation: Short press to rotate the screen in clockwise. This operation can only be done in full display measuring page.
- Data storage: Long press to save the current result. The storage icon and record number shows on the right top of the screen. This operation can only be done when the result is locked.
Others
General Problems
- Cannot be power on: Out of battery.
- No result for acceleration testing: switch different frequency testing mode, for instance, switch low frequency acceleration into high frequency.
- The acceleration reading is unstable: check if the sensor and probe are loose. Tighten it, then test again if it is.
Maintenance
- Working environment: the vibration meter is a precise device, so keep it strictly from crash, impact, humid, strong current, magnetic field, greasy and dust environments.
- Changing batteries and maintenance
- Please change batteries when on LCD screen shows low-power icon .
- Please take batteries out if no operations for a long while, in case the leakage of batteries which can severely damage the device.
- Do not disassemble or reform inner construction of this device.
- Surface cleaning: Ethyl alcohol、diluent have corrosive effect on the body surface of the device, especially the LCD window, so please just scrub it gently with a bit of pure water.
Appendix
- **Machine vibration grading form(ISO2372)
Attention:
**
1. Ⅰtype is small-sized motor that its power is below 15kw;Ⅱtype is medium-sized that its power is from 15kw to 75kw;Ⅲ type is large-scale original motor(based on hardness connection); Ⅳ type is based on resilient connection.
2. Vibration grades:A,B,C,D grade. A for good, B for satisfaction,
C for unsatisfaction, D for unallowed. Measure velocity RMS value should be in three orthogonal directions of the bearing cap.
- The max limited vibration value for motors that its power is beyond 1 horsepower(NEMA MG1-12.05)
REV(r/min)| peak-to-peak displacement amplitude(µm)
---|---
3000~4000| 25.4
1500~2999| 38.1
1000~1499| 50.8
≤999| 63.6
For AC motor, the rev is the top synchronous speed; For DC motor or multi- purpose motor, it is working rev.
- The Max limited vibration value of lager-scale inductive motor(NEMA MG1-20.52)
REV(r/min)| peak-to-peak displacement amplitude(µm)
---|---
≥3000| 25.4
1500~2999| 50.8
1000~1499| 63.6
≤999| 76.2
Both standards above are made by National Electrical Manufactures Association in America(NEMA).
- Performed winding squirrel-cage inductive motor
synchronous speed(r/min)| peak-to-peak displacement amplitude(µm)
---|---
elastic support| steel support
720~1499| 50.8| 63.6
1500~2999| 38.1| 50.8
≥3000| 25.4| 25.4
This standard is made by American petroleum institute(API)
- ISO/IS2373 The quality standard based on vibration velocity amplitude
grade of quality
|
REV(r/min)
| shaft heightH(mm), max velocity amplituderms(mm/s)
---|---|---
80<H<132| 132<H<225| 225<H<400
N(normal level)| 600~3600| 1.8| 2.8| 4.5
R(good level)| 600~1800
1800~3600
| 0.71
1.12
| 1.12
1.8
| 1.8
2.8
S(special level)| 600~1800
1800~3600
| 0.45
0.71
| 0.71
1.12
| 1.12
1.8
This threshold value of “N” in the table applies to normal motor.
Web: www.hazari.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>