DIMENSIONS AND INSTALLATION INFORMATION
Installation Instructions:
- Select a level surface that provides enough open space for the intake and/or outlet vents.
- A minimum clearance of 3.0 inches (7.5 cm) is required between the oven and all adjacent walls; one side must be open.
- Leave a minimum clearance of 12 inches (30 cm) above the oven.
- Do not remove the legs from the bottom of the microwave oven.
- Blocking the intake and/or outlet openings can damage the oven.
- Place the microwave oven as far away as possible from radios and television, as the operation of the microwave oven, may cause interference with the devices.
- Plug your microwave oven into a standard household outlet that matches the voltage and frequency on the rating label.
Warning: Do not install the microwave oven over a range cooktop or other
heat-producing appliances, another heat source could damage the microwave
oven, voiding your warranty.
TRIM KIT LOCATION REQUIREMENTS
- The microwave oven may be installed over a built-in oven. If installing over a built-in oven, ensure there is a minimum of 3” (7.6 cm) between the top of the lower oven cutout and the microwave oven cutout floor.
- The microwave oven may also be installed in a cabinet without a built-in oven below. We recommend a minimum distance of 36” (91.4 cm) from the floor to the cutout floor.
- Ensure the surrounding cabinetry has clearance to open and close freely. Allow a clearance of at least 1 9/16” (4 cm) below the cutout floor, 3” (7.6 cm) for installation above a built-in oven and a 2” (5.1 cm) above the cutout opening.
REQUIRED CUTOUT DIMENSIONS
- Height dimension is critical: 17” (43.2 cm) minimum and 17 1/8” (43.5 cm) maximum.
- Width and depth measurements have a 1/16” (2mm) tolerance.
- 3” (7.6 cm) minimum dimension is from the lower oven cutout ceiling to the microwave oven cutout floor.
- The Trim kit frame extends 1 1/16” (2.7 cm) above and below the cutout opening.
TRIM KIT FRAME DIMENSIONS
forteappliances.com
support@forteappliances.com
718-249-1215
1870 Bath Avenue, Suite 3, Brooklyn, NY 11214
Spec sheets are subject to change without notice.
For further questions and more detailed information, please visit
forteappliances.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>