TRM690G Radio Transmitter Receiver 2 Inputs 1 Output 200W
Radio transmitter/receiver.
2 inputs + 1 output 200W
– This unit is to be installed by a qualified professional only according to
the installation standard in force in the country.
– Cut off 230V power supply to the product before connection of or operation
on the inputs.
– Do not remove the insulating sleeves on the unused input wires.
TRM690G is a power supplied radio transmitter/ receiver 2-wire, supplied in
series with the 230 V load. It is used to control incandescent, LV and ULV
halogen, and dimmable LED lights. It includes :
2 inputs for connection of pushbuttons, switches or other automatic control
contacts.
One output to connect an electric load in ON/ OFF mode.
The inputs connected to the product are freely programmable. They can control
the local output or other outputs.
This product is part of the tebis system and can be remotely controlled by
radio transmitters input products, push-buttons, remote controls.
Caption
- Pushbutton or standard switch
- Wires for connecting the 2 inputs for a switch or pushbutton
- Pushbutton and feature LED T of output.
- Pushbutton and configuration LED R
- Connector block :
– L : Phase 230 Vv
– : Output connection, 230 V
Do not cut the input wires, even if they are not used.
Features
-
1 independent channel controlled by KNX radio. (output 200W AC1 230 V).
-
2 inputs for contact free of potential.
In operation : -
Availability of output manual control by pushbutton T
-
Display of output state on LED fct (red light ON = closed relay).
The specific features of each product depend on configuration and set-up.
Learning the load type
The first time it is turned on, the product undertakes automatic learning of
the connected lamp type. A brief flicker may be observed during this phase
(duration 2 to 3 s) after which the lamp type is stored in the product.
After a power outage or change of lamp, the dimmer starts a new detection.
If the user notices unsatisfactory operation, the setting can be edited
manually.
Manual setting of the load
Make 5 consecutive short presses on the dimmer pushbutton, until the lamp is
observed to flash. The dimmer is now in manual setting mode.
Briefly press the dimmer pushbutton to select the desired setting: (see table
below)
Note: Automatic departure from manual mode and setting validation occur
after 10 s inactivity.
Dimming pushbutton No. of short presses | No. of blinks | Setting type |
---|---|---|
1 x | 1 x | Automatic detection mode (default value) |
2x | 2x | Standard LED mode |
3x | The lamp is lit at the minimum level = minimum threshold setting mode |
active. Further presses of the dimming pushbutton are used to test other levels (to perform the test in the dark). Saving of the minimum threshold after 10 s inactivity
Protection against overheating and overload
The product is automatically protected againstoverloads, short circuits and
overheating. In theevent of overheating or overload, the availablepower is
automatically reduced.
Configuration
This transmitter/receiver can be configured in 3
different ways:
-
: Configuration without tool, see
Quicklink configuration instructions -
Tebis TX : Configuration»easy» with the Hager connection device
-
ETS4 or > via Media coupler : Database and description of software application available from the Manufacturer.
In order to change the configuration mode, a product «factory reset» is
required.
Factory set-up
By default, input 1 is configured to receive a pushbutton or a switch and to
control the local output in toggle switch function. This link can be edited or
deleted in configuration mode.
A factory reset of the product reinstalls this link (factory settings).
Input 2 is not pre-programmed.
Factory Reset
Maintain R pushbutton down until LED cfg flickers (>10s), then release. Cfg
LED turns OFF to signal Factory Reset end. This operation removes the entire
product configuration in any configuration mode.
After power switch-On or Factory Reset, wait for 15s before to do a new
configuration.
These instructions for use form an integral part of the product and must be
retained by the end user. www.hager.com
Load type
| 230 V| Incandescent lamps| 10 … 200 W
---|---|---|---
| 230 V| alogen lamps| 10 … 200 W
| 230 V| Halogen ELV (12 or 24 V) via ferromagnetic
transformer| 10 … 175 VA
| 230 V| Halogen ELV (12 or 24V) via electronic
transformer| 10 … 175 VA
LED | 230 V| Dimmable LEDs| 3 … 50 W
Non-dimmable LED and compact fluorescent lamps are not compatible with this product.
Technical characteristics
Supply voltage| 230 V +10 %-15% 50 Hz
240 V +6%/-6% 50 Hz
---|---
Product consumption| 100mW
Upstream protection: circuit breaker| 10A
Transmission frequency/ Emission power| 868-870 MHz 25 mW
Communication media| KNX : RF1.M
Dimensions| 40 x 40 x 18 mm
Max. connection distance per input| < 10 m
Minimum contacts closing time| 50 ms
Degree of protection| IP 20
Operating altitude| ≤ 2000 m
Pollution degree| 2
Overvoltage category| III
Operating temperature| -15 °C —> + 45 °C
Storage temperature| – 25°C —> + 70 °C
Receiver category 2 / Transmitter duty cycle 0,1%
Electric connection 0,5 mm —> 1,5 mm 2 0,5 mm —> 2,5 mm 2
Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703
SAVERNE CEDEX, France – www.hager.com
Documents / Resources
|
hager TRM690G Radio Transmitter Receiver 2 Inputs 1 Output
200W
[pdf] User Manual
TRM690G Radio Transmitter Receiver 2 Inputs 1 Output 200W, TRM690G, Radio
Transmitter Receiver 2 Inputs 1 Output 200W, Transmitter Receiver 2 Inputs 1
Output 200W, Receiver 2 Inputs 1 Output 200W, 2 Inputs 1 Output 200W
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>