hama 186420 Rainy Weather Station Instruction Manual

June 4, 2024
Hama

186420 Rainy Weather Station
Instruction Manual

186420 Rainy Weather Station


hama 186420 Rainy Weather Station


hama 186420 Rainy Weather Station - fig1hama
186420 Rainy Weather Station - fig2

Controls and Displays

ABase station

  1.  LIGHT button
    =activates the backlight (approx. 10 seconds) /manual
    Search for a signal from the wireless rain gauge

  2. Display

  3. Outdoor temperature

  4. DCF radio symbol

  5. Time

  6. Day of the week

  7. Day

  8. Month

  9. Year

  10. Room temperature

  11. Rainfall histogram

  12. Rainfall display

  13. Rain alarm symbol

  14. Battery status symbol

  15. Measuring station +wireless rain gauge wireless symbol

  16. „ “button
    =switches between °C and °F /set the time and date

  17. ‘ ’button
    =increases the current set value /manual search for a signal from the measuring station

  18. ‘ ’button
    =displays the stored maximum/minimum outdoor and indoor temperature values /reduces the current set value

  19. ‘RAIN’ button
    =rainfalldisplay (1H/24H/WEEK/MONTH/TOTAL)

  20.  ‘   ’button
    =displays rain alarm value /sets rain alarm value

  21. Rain alarm ON/OFF slide switch
    =activates/deactivates the rain alarm

  22. Recess for wall mounting

  23. Battery compartment

  24. Battery compartment release

  25. Base
    B measuring station

  26. Transmission indicator light

  27. Recess for wall mounting

  28. Channel selection

  29. Battery compartment
    C Wireless rain gauge

  30. Rain gauge cover

  31. Drill holes for ground mounting

  32. Locks for the rain gauge cover

  33. Spirit level

  34. Rocker

  35. Battery compartment

Explanation of Warning Symbols and Notes

Warning
This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.
Note
This symbol is used to indicate additional information or important notes.

Package Contents

  • ‘RAINY’ weather station with wireless rain gauge (base station for indoors /measuring station and wireless rain gauge for outdoors)
  • 4AAA Micro batteries
  • 2AAMignon batteries
  • These operating instructions

Safety Notes

  • The product is intended for private, non-commercial use only.
  • Use the product for its intended purpose only.
  • Protect the product from dirt, moistureand overheating, and only use it in a dry environment.
  • Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
  • Keep this product, as all electrical products, out of the reach of children!
  • Do not operate the product outside the power limits given in the specifications.
  • Do not use the product in areas wherethe use of electronic devices is not permitted.
  • Do not use the product in moist environments and avoid splashes.
  • Do not place the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the functionality of the product.
  • Do not drop the product and do not expose it to any major shocks.
  • Do not modify the product in any way. Doing so voids the warranty.
  • Keep the packaging material out of the reach of children due to the risk of suffocation.
  • Dispose of packaging material immediately according to locally applicable regulations.
  • Do not open the device or continue to operate it if it becomes damaged.
  • Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
  • Use the item only in moderate climatic conditions.

Warning –Batteries

  • When inserting batteries, note the correct polarity (+ and -markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
  • Only use batteries (or rechargeable batteries) that match the specified type.
  • Before you insert the batteries, clean the battery contacts and the polar contacts.
  • Do not allow children to change batteries without supervision.
  • Do not mix old and new batteries or batteries of a different type or make.
  • Remove the batteries from products that arenot being used for an extended period (unless these are being kept ready for an emergency).
  • Do not short-circuit batteries.
  • Do not charge batteries.
  • Do not throw batteries in a fire.
  • Keep batteries out of the reach of children.
  • Never open, damage, or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Immediately remove and dispose of dead batteries from the product.
  • Avoid storing, charging, or using the device in extreme temperatures and extremely low atmospheric pressure(for example, at high altitudes).

Getting Started

Note
Before use, make surethat you insert the batteries into the measuring station and the wireless rain gauge first, and then into the base station.

4.1 Insert batteries

Measuring station

  • Open the battery compartment (29) and remove the contact breaker.
  • Then close the battery compartment cover.

Wireless rain gauge

  • Remove the rain gauge cover (30) by simultaneously pressing both locks (32), on either side, inwards.
  • Open the battery compartment (35) next to the rocker (34), and insert two AAA Micro batteries with the correct polarity.
  • Then close the battery compartment cover.
  • Now replace the rain gauge cover (30), and press it down until the two locks (32) snap into place on either side.

Base station

  • Remove the screen protector from the display.
  • Open the battery compartment (23) and insert two AAA Micro batteries with the correct polarity.
  • Then close the battery compartment cover.

4.2 Replacing the batteries
Note –Replacing the batteries

  • Note that the stations have to be resynchronized each time you change the batteries in the measuring or base station or in the wireless rain gauge.
  • To do this, remove the batteries from the other station and then reinsert them, or change them as required.

Measuring station

  • Open the battery compartment (29), remove and properly dispose of the depleted batteries, and insert two new AA Mignon batteries with the correct polarity. Then close the battery compartment cover.

Wireless rain gauge

  • Remove the rain gauge cover (30) by simultaneously pressing both locks (32), on either side, inwards.

  • Open the battery compartment (35) next to the rocker (34), remove and properly dispose of the depleted batteries, and insert two new AAA Micro batteries with the correct polarity.
    Then close the battery compartment cover.

  • Now replace the rain gauge cover (30), and press it down until the two locks (32) snap into place on either side.

Base station

  • Open the battery compartment (23), remove and properly dispose of the depleted batteries, and insert two new AAA Micro batteries with the correct polarity. Then close the battery compartment cover.

Installation

Warning

  • Buy special or suitable installation material from a specialized dealer for wall mounting.
  • Ensure that no faulty or damaged parts are installed.
  • Never apply force during installation. This could damage the product.
  • Before installation, ensure that the chosen wall is suitable for the weight to be mounted, and make surethat there are no electrical wires, water, gas, or other lines at the installation site on the wall.
  • Do not mount the product above locations where persons might linger.

Note –Installation

  • We recommend initially placing the base station, measuring station and wireless rain gauge in the intended locations without installing them, and making all the settings described in 6. Operation.
  • Only install the stations once the appropriate settings have been made and an astable wireless connection is established.

Note

  • The wireless transmission range between the measuring station, base station, and wireless rain gauge is up to 100 min open spaces.
  • Before installation, ensure that wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, high-voltage lines, etc.
  • Before final installation, ensure that there is sufficient reception between the intended installation locations.
  • When installing the measuring station, ensure that it is protected from direct sunlight and rain.
  • The international standard height for measuring air temperature, according to the German Meteorological Service, is 2m(6.5 ft) above ground.

5.1 Base station

  • Use the base to position the base station (25) on a level surface.
  • Alternatively, you can install the base station on a wall using the opening (22) on the back.

5.2 Measuring station

  • You can also position the measuring station on a level outdoor surface.
  • We recommend installing the measuring station securely on an outdoor wall.
  • Install an anchor, screw, nail, etc. in the wall of your choice.
  • Hang up the base/measuring station using the opening (27) intended for this purpose.

5.3 Wireless rain gauge

  • You can also position the wireless rain gauge on a level outdoor surface.
  • It is recommended that you position the wireless rain gauge safely, stably, and horizontally in an area that is not covered by trees, roof eaves, etc., to allow rain to fall into the container without obstruction. If necessary, use the integrated spirit level (33).
  • Install an anchor, screw, nail, etc. into the intended undersurface.
  • Secure the wireless rain gauge using the drill holes provided (31).

Operation

Note
Hold down the ‘ ’button (17) or the ‘ ’button (18) to select the values faster.

6.1 Connection to the measuring station and wireless rain gauge

  • After you have inserted the batteries, the base station automatically searches for a connection to the measuring station and the wireless rain gauge and performs the initial setup.

Note

  • Initial setup takes approx. 2minutes.
  • During the connection attempt, the measuring station + wireless rain gauge wireless symbol (15) will flash.
  • Do not press any buttons during setup. Otherwise, values may not be transmitted correctly and thereisarisk of value errors and inaccuracies.
  • The setup process is completed when the indoor (10) and outdoor (3) measurement data is displayed.
  • The measured value is automatically updated by the base device about every 45 seconds.
  • If the temperature is outside of the measuring range, –.- (lower than minimum temperature) or –.- (higher than maximum temperature) will appear on the temperature display.
  • If the base station consistently receives no signal from the wireless rain gauge, press and hold the LIGHT button (1) for approx. 3 seconds to start the manual search for the signal.
Display Search for a signal from the measuring station
Display flashing Active
Displayed continuously Successful – signal is being received
Displayed continuously Inactive – No signal received from measuring station

hama 186420 Rainy Weather Station - InactiveDisplayed continuously| Inactive – No signal received from wireless rain gauge

Note –Faulty transfer of measured values

  • In isolated cases, interference –for example, from a WLAN network, a computer, or a television set –can cause the transfer of measured values between the measuring station, wireless rain gauge, and base station to fail.
  • In this case, you must resynchronize the stations by briefly removing the batteries from all stations and reinserting them.
  • If the measured values arenot transferred again once the batteries are inserted, replace the batteries with new ones.
  • If necessary, select a new location for the base station in order to avoid possible interference in the future.

6.2 Basic and manual settings
Automatic setting using the DCF signal

  • After the base station has been switched on for the first time and successful transmission has been established between the base station, measuring station, and wireless rain gauge, the clock will automatically search for the PCF signal. During the search, the wireless symbol (4) will flash.
  • When the radio signal is received, the date and time are automatically set.
Radio icon Signal strength
No symbol No reception
**** Poor
Excellent
Radio icon Searching for the DCF signal
--- ---
Flashing display Active
Constant display Successful –signal is being received
No display Error –signal search ended

Note –Time settings

  • If during the initial setup of the device, the PCF radio signal is not received within the first few minutes, the search is aborted. The radio symbol disappears.
  • If there are reception problems, we recommend leaving the clock to sit overnight, since interference is generally less at night.
  • In the meantime, you can start the manual search for the DCF radio signal at another location or you can manually set the time and date.
  • The clock automatically continues to search for the DCF radio signal on a daily basis (1:00 a.m., 2:00 a.m., and 3:00 p.m.). If the signal is received successfully, the manually set time and date areoverwritten
  • Press and hold the ‘   ’button (18) to start the manual search for the DCF radio signal.
  • Press the ‘  ’button (18) again to interrupt the manual search for the DCF radio signal.

Manually setting the date/time

  • Press and hold the ‘ ’button (16) for approximately 3 seconds to make the following settings one after the other.
  • Time zone
  • 12/24-hour format
  • Hour
  • Minute
  • Year
  • Month
  • Day
  • Language setting for the day of the week
  • The setting of the rain measuring unit (mm/inch)
  • To select the individual values, press the ‘   ’button (17) or the ‘ ’button (18) and confirm each selection by pressing the ‘  ’button (16).
  • Press the ‘   ’button (16) to adopt the set value displayed and to skip.
  • If you do not make an entry for 10 seconds, you automatically exit Settings mode.

Note –Time zone

  • The DCF signal can be received over long distances, but always transmits the current Central European Time in Germany. Make sure you account for the time difference in countries with another time zone.
  • If you are in Moscow, the time is 3 hours later than in Germany. This means that you should set +3 for the time zone. The clock then automatically sets the time to 3 hours after the DCF signal is received or relative to the manually set time.

Note –Day of the week
You can choose from German (GER), English (ENG), French (FRE), Italian (ITA), Spanish (SPA), Dutch (DUT), and Danish (DAN) for the day of the week display.

6.3 Celsius/Fahrenheit

  • Press the ‘   ’button (16) when in any mode to choose between °C (Celsius) and °F (Fahrenheit).

6.4 Maximum and minimum temperature values

  • The base station automatically stores the maximum and minimum temperaturevalues in the outdoor and indoor areas.
  • Press the ” “button (18) repeatedly to toggle between the display of the current temperature, lowest temperature(MIN), and maximum temperature(MAX).
  • The maximum and minimum temperatures are displayed for 10 seconds.
  • Press and hold the “   “button (18) when the stored maximum (MAX) and minimum (MIN) values are displayed to reset them.

6.5 Backlight
Note –Backlight

  • If you press the LIGHT button (1), the display will light up for approx. 10 seconds.

6.6 Low battery charge
As soon as the battery symbol appears on the display of the base station, the capacity of the batteries in the measuring station is very low. Replace the batteries immediately.
Note –Replacing the batteries

  • Note that the stations have to be resynchronised each time you change the batteries in the measuring or base station or in the wireless rain gauge.
  • To do this, remove the batteries from all stations and then reinsert them, or change them as required.

Wireless rain gauge

Note
The fallen precipitation is measured in millimeters (mm). 1 mm of the precipitation corresponds to a precipitation amount of 1l/m². The average amount of precipitation per year in Germany is approx. 800 mm ^= 800 l/m².
7.1 Rainfall display

  • The rainfall is displayed in the form of a histogram (11).
  • The histogram shows the precipitation values for the last 6 hours (max. display range: 5mm–50mm).
  • Press the RAIN button (19) in any mode to switch between the following rainfall displays (12):
  • 1H =rainfall in the last hour
  • 24H =rainfall in the last 24 hours
  • WEEK =rainfallinthe last week
  • MONTH =rainfallinthe last month
  • TOTAL =total rainfall since first-time use or the last reset
  • Press and hold the RAIN button (19) in the respective rainfall display to reset the stored precipitation amounts.
    Each rainfall display (1H/24H/WEEK/MONTH/TOTAL) can be individually reset.

Note –Rain alarm, 24-hour count
The rain alarm informs you as soon as the amount of precipitation exceeds a user-definable value. If this value is reached within 24 hours, the base station will emit a beep.
The data is deleted daily at 24:00 hours.
7.2 Setting the rain alarm

  • Press the ‘ ’button (20) in any mode to display the current rain alarm value for approx. 10 seconds (presetting: 12.7 mm).
  • To change the preset alarm value, keep the ‘ ’button (20) pressed; the preset alarm value flashes.
  • To select the value, press the ‘ ’button (17) or the ‘ ’button (18), and confirm your selection by pressing the ‘ ’button (20).
  • If you do not make an entry for 10 seconds, the device automatically exits the settings mode, and the settings you made are saved.

7.3 Activating/deactivating the rain alarm

  • Move the rain alarm ON/OFF slide switch (21) to the left to the ON position. The rain alarm is activated and the rain alarm symbol (13) appears on the display (2).
  • Move the rain alarm ON/OFF slide switch (21) to the right to the OFF position. The rain alarm is deactivated and the rain alarm symbol (13) disappears from the display (2).

7.4 Stopping the rain alarm

  • If the rain alarm is activated and the set alarm value is exceeded, the alarm is triggered and a beep will sound on the base station for two minutes. The rain alarm symbol (13)flashes. After that, the rain alarm stops automatically.
  • Press the LIGHT button (1) or any other button of your choice to stop the rain alarm manually.

Care and Maintenance

Only clean this product with a slightly damp, lint-free cloth, and do not use aggressive cleaning agents. Make surethat water does not get into the product.

Warranty Disclaimer

Hama GmbH &CoKG assumes no liability and provides no warranty for damage resulting from improper installation/ mounting, improper use of the product, or from failure to observe the operating instructions and/or safety notes.

Technical Data

Weather Station

Max. transmitting power| Measuring station
1.5 V 2AAMignon batteries| Base station
1.5 V2AAA Micro batteries| Wireless rain gauge
1.5 V 2AAA Micro batteries
---|---|---|---
Measuring range for temperature| | Indoors: -10°C –+50°C /+14°F –+122°F
Outdoors: -40°C –+60°C /-40°F –+140°F|
Range| | Approx. 100 m|

Declaration of Conformity

Hereby, Hama GmbH &CoKG declares that the radio equipment type [00186420] is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.hama.com->00186420->Downloads.

Frequency band(s)| Measuring station 433.92 MHz
Wireless rain gauge 433.92 MHz
---|---
Maximum radio-frequency power transmitted| Measuring station 0.14 mW
Wireless rain gauge 0.16 mW

Hama GmbH &CoKG
86652 Monheim /Germany
Service &Support
www.hama.com
+49 9091 502-0
hama 186420 Rainy Weather Station - battery

All listed brands are trademarks of the corresponding companies. Errors and omissions excepted, and subject to technical changes. Our general terms of delivery and payment are applied.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals