sensitron SMART3G-C2 Gas Detector Instructions
- June 12, 2024
- sensitron
Table of Contents
sensitron SMART3G-C2 Gas Detector
Product Information
The SMART3G-C2 gas detector with catalytic sensor is designed to meet
industrial requirements. The enclosure is explosion-proof and can be installed
in ATEX Zone 1 and, when equipped with a dust adapter, in Zone 21. The sensing
element is placed in a stainless
steel head, with two available options: Type head 2 with a 40 mm diameter and
Type head 3 with a 48 mm diameter. The gas detector utilizes pellistor sensors
for flammable gas detection, offering excellent output linearity up to 100%
LEL and fast response time.
The SMART3G-C2 gas detector has a power supply of 12-24 Vdc and a standard 4-20 mA 3-wires output. It can also be equipped with optional serial RS485 communication and a 1 or 3 relays board. The aluminium enclosure has dimensions of 120 x 162 x 90 mm when equipped with Type head 2 and 120 x 184 x 90 mm when Type head 3 is used. The enclosure has 3 cable entries with 3/4 NPT threaded connections.
The gas detector can be ATEX marked as follows: 0722 II 2G Ex db IIC T5 Gb. When equipped with a dust adapter, it is SIL2 hardware and SIL3 software. With a redundant system, the hardware is also SIL3.
Product Usage Instructions
Sensor:
- Application: Industrial area, ATEX Zone 1 and Zone 21 (when equipped with dust adapter, optional)
- Sensing element: Catalytic
- Predicted sensor lifetime: 4 / 5 years
- Gas detected: Flammable gas
- Full scale: 0 – 100% LFL
Electrical data:
- Power supply: 12-24 Vdc
- Output: Analogue 4-20 mA output; 1 or 3 relay board (optional); serial RS485 output (optional)
- Maximum dissipated power: 5.4 W
- Relays contact ratings (optional board): 1.0 A at 24 Vdc
Environmental conditions:
-
Storage temperature: N/A
-
Operating temperature: N/A
-
Operating humidity: N/A
-
Operating pressure: 80 / 120 kPa *
-
Air velocity: 6 m/s *
-
Time of response: t90 < 60 s; t50 < 20 s
-
Data tested with tests described in EN 60079-29-1 standard
External case:
- Material: Enclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant; Sensor head: stainless steel
- Protection mode: Ex d: Explosion-proof enclosure, Ex t: Equipment dust ignition protection by enclosure (when equipped with dust adapter, optional)
- Dimensions: With Type head 2: 120 x 162 x 90 mm, With Type head 3: 120 x 184 x 90 mm
- Weight: With Type head 2: 1050 g, With Type head 3: 1250 g
- Cable entries: 3 x 3/4 NPT
- IP grade: IP65
Compliance:
- EMC: EN 61000-6-3:2007 + A1:2011; EN 50270:2015
- ATEX directive: 2014/34/EU EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-31:2014 EN 60079-29-1:2016
- IECEx: IEC 60079-0:2011 IEC 60079-1:2014 IEC 60079-31:2013
- SIL: EN 61508:2010 Parts 1, 2, 3, 4, 5, 6, 7 EN50402:2017
Note: Sensitron srl reserves the right to change technical data without notice. For updated product characteristics, please check the website www.sensitron.it or contact sales@sensitron.it.
Product Codes:
- ATEX code: S2097ME Methane gas detector, 12-24 Vdc
For more information and inquiries, please contact Sensitron srl at the following:
Address: Viale della Repubblica 48, Cornaredo (MI) – 20007
Email: sales@sensitron.it
Telephone: +39 0293548155
Fax: +39 0293548089
-
SMART3G-C2 gas detector is designed to meet industrial requirements; the enclo-sure is explosion-proof and can be installed in ATEX Zone 1 and, when equipped with dust adapter, in Zone 21.
-
The sensing element is placed in the stainless steel head. Sensitron has developed two type heads with different dimensions: the model “Type head 2” has a 40 mm diameter, the “Type head 3” version has a 48 mm diameter. The pellistor sensors employed for flammable gas detection show an excellent output linearity up to 100% LEL and fast time of response.
-
The gas detector has a 12-24 Vdc power supply and a standard 4-20 mA 3-wires output. Optionally, the SMART3G-C2 can be equipped with serial RS485 communication and a 1 or 3 relays board.
-
The aluminum enclosure has dimensions 120 x 162 x 90 mm when equipped with type head 2, 120 x 184 x 90 mm when the head type 3 is used. The enclosure has 3 cable entries 3/4” NPT threaded.
-
The gas detector can be ATEX marked as follows:
-
0722 II 2G Ex db IIC T5 Gb Or, when equipped with dust adapter:
-
0722 II 2GD Ex db IIC T5 Gb Ex tb IIIC T100°C Db IP65
-
The gas detector is IECEx compliant and can be marked as follows:
Ex db IIC T5 Gb -
Or, when equipped with dust adapter:
Ex db IIC T5 Gb
Ex tb IIIC T100°C Db -
IP65
SMART3G-C2 is SIL2 hardware and SIL3 software; with a redundant system also the hardware is SIL3.
-
SPECIFICATION
- Data tested with tests described in EN 60079-29-1 standard
Product codes
Mechanical drawings
Sensitron srl works for a constant improvement of its products and reserves the right to change the technical data without notice. To have the updated product characteristics check on the website www. sensitron.it or write an e-mail to sales@sensitron.it
DS4737E R6 11/03/2022
Sensitron srl, Viale della Repubblica 48, Cornaredo (MI) – 20007
sales@sensitron.it
TEL. +39 0293548155
FAX. +39 0293548089
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>