ETC ColorSource PAR v1.7 Affordable LED Fixture Installation Guide
- June 12, 2024
- ETC
Table of Contents
ETC ColorSource PAR v1.7 Affordable LED Fixture
Product Information
The ColorSource PAR is a professional lighting fixture designed for use in various settings. It comes in different versions, including v1.7, v3.0, and v4.0, and requires the latest software version for optimal performance. The fixture features safety measures to ensure proper usage and includes connectors for data input and output.
Safety Precautions
- This equipment is for professional use only. Read the entire manual before using the fixture.
- Follow all safety instructions provided in the manual.
- Install the luminaire at least 0.1 m (4.0 in) away from all lighted objects.
- Avoid mounting the fixture on or near flammable surfaces.
- Do not stare directly at the operating light source to prevent eye strain.
- Dispose of the product responsibly by sending it to separate collection facilities for recovery and recycling.
Installation
Mounting: The ColorSource PAR comes with a standard yoke for mounting using a clamp. An expandable floor stand yoke is available as an optional accessory.
Safety Cable: Attach a safety cable (or other approved safety device) to the fixture using the attachment loops on the rear. Ensure minimal slack in the safety cable to avoid catching the yoke of the fixture.
Connectors: The fixture includes RJ45 connectors for data input and output. Conversion cables are available from ETC for connecting to XLR sockets or plugs.
Set Up:
- Plug the power cord into the powerCON In connector on the rear of the fixture.
- If using power-thru cables, make the necessary connections before applying a power source.
- Make any DMX connections, and if the fixture is the last in a DMX line, terminate it with a 120 Ohm resistor.
- Plug the power cord into the power source.
User Interface
To power up the fixture, press any button to wake the display. The display
will show the DMX address. The Mode button can be used to access the
Presets/Sequences menu for playing presets and sequences.
Overview
The ColorSource PAR is an affordable LED fixture that uses the RGB-L (red,
green, blue, and lime) color system to provide a rich, bright light.
The ColorSource PAR is available in both original and Deep Blue variants. The
Deep Blue uses an array that offers richer, more saturated blues and stronger
magentas in exchange for the more jewel-toned blues like sky or turquoise. For
more information, see the ETC website at
etcconnect.com.
The ColorSource PAR is UL924 listed as a Directly Controlled Luminaire for use
in emergency lighting systems when used with the ETC DMX Emergency Bypass
Controller (DEBC).
Note: Features described in this document require the latest version of software. For information on updating fixture software, see Update the Fixture Software on page 11.
Safety
For professional use only. Read the entire manual before using this equipment.
WARNING:
- Risk of eye injury. Do not stare directly into the light.
- Do not mount the fixture on or near a flammable surface.
- When the fixture is mounted, the axis between the yoke attachment points must be parallel to the ground. Mounting the fixture in a non-parallel orientation risks property damage or bodily injury.
- Disconnect the fixture from power and DMX and allow it to cool before installing accessories or performing any cleaning and maintenance.
WARNING: The ColorSource PAR is a Directly Controlled Luminaire suitable for use in emergency lighting applications in accordance with 2017 National Electrical Code section 700.24 when used with an ETC DMX Emergency Bypass Controller. The response time to DMX control from application of power is 3 seconds. Equipment intended for this purpose must be properly selected, installed, and maintained so that facility conformance can be obtained. Installation and servicing shall be performed by qualified service personnel.
WARNING: RISK OF ELECTRIC SHOCK! The light source in this luminaire is not user-replaceable, and must be replaced only by a qualified technician. Contact ETC Customer Support for assistance.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- Do not use outdoors.
- Do not let power supply cords touch hot surfaces.
- Do not mount near gas or electric heaters.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Do not use this equipment for other than intended use.
SAVE THESE INSTRUCTIONS
The following symbols may appear on product labeling.
| The luminaire must be installed at least 0.1 m (4.0 in) away from all
lighted objects.
---|---
| Do not mount the fixture on or near a flammable surface.
| Risk of electric shock
| Do not stare at the operating light source.
| This product should not be discarded as unsorted waste but must be sent to
separate collection facilities for recovery and recycling.
| Protective earth (ground)
Emergency Lighting Considerations
Luminaires that are used in emergency lighting applications must provide a
minimum illumination level over the identified means of egress path in
accordance with the Life Safety Code®, NFPA 101. A luminaire that is intended
to serve this purpose must be mounted at a height where it will not readily be
subjected to tampering by unauthorized personnel and where the minimum
required illumination level over the egress path can be achieved. The ETC DMX
Emergency Bypass Controller that is driving the luminaire upon loss of utility
power must be programmed to drive the ColorSource PAR to full illumination.
For more information, see the DMX Emergency Bypass Controller Installation
Guide, available for download at etcconnect.com.
Installation
Mounting
The ColorSource PAR ships with a standard yoke for mounting with a clamp.
An expandable floor stand yoke is available as an optional accessory. Contact
your local dealer for more information.
Safety Cable
A safety cable (or other approved safety device) must be attached to the
fixture. Attachment loops are on the rear of the fixture. Leave as little
slack as possible in the safety cable to avoid catching the yoke of the
fixture.
Connectors
- Power: Two powerCON® connectors for power in and thru
- Data (DMX512/RDM): Two five-pin XLR connectors OR two RJ45 connectors for data in and thru
Conversion cables are available from ETC. Please contact your ETC customer service representative and request part number W6538 for RJ45 to socket XLR or part number W6539 for RJ45 to plug XLR.
Note: This fixture is not Ethernet/data network compatible.
Note: The ColorSource PAR is not self terminating. You must terminate the
last fixture in line with a 120 Ohm resistor. To
purchase a terminator, please contact ETC customer service and request part
number N4086 (RJ45 terminator) or SGE1507 (XLR terminator).
Set Up the Fixture
- Plug the power cord into the powerCON In connector on the rear of the fixture.
- Make any power-thru cable connections prior to applying a power source.
- Make any DMX connections, and if the fixture is the last in a DMX line, terminate the fixture. See Connectors above.
- Plug the power cord into the power source.
Power Up
Press any button to wake the display. The display shows the DMX address.
See Set the DMX Address below.
You can press the Mode button to access the Presets/Sequences menu. See Play
Presets and Sequences on page 9.
Adjust the Tilt
The fixture can be tilted up and down and rotated (panned) as needed.
- Loosen, but do not remove the yoke locking knob.
- Tilt the fixture to the desired angle.
- Tighten the yoke locking knob.
Set the DMX Address
- Press any button to wake the display. The display shows the DMX address.
- Use the Up and Down buttons to select the DMX address for the fixture.
You can also use RDM for DMX addressing. See RDM Values on page 14.
Change the DMX Control Mode
You can set the DMX control mode for the fixture to one of four available mode
options.
- Press any button to wake the display. The display shows the DMX address.
- Press and hold the Mode button for 3 seconds. The display shows the current DMX control mode.
- Press the Up button or Down button to change the DMX control mode. ( The currently saved mode is indicated by a decimal point at the end of the mode name.)
- 5ch: 5-channel mode (intensity, red, green, blue, and strobe). This is the default mode.
- dir: Direct emitter control (intensity, red, green, blue/indigo, lime, and strobe).
- 1ch: 1-channel mode controls the intensity of preset 1 (defaults to 3200 K White).
- rgb: RGB mode (red, green, and blue).
- Press the Mode button to confirm your selection.
The display will automatically return to the DMX address after 10 seconds of inactivity, and edits to the DMX control mode will not be saved. This cancels unsaved changes.
DMX Control Channels
DMX Channel| 5ch (5 channel)| d i r (Direct)| 1ch (1
Channel)| rgb (RGB)
---|---|---|---|---
1| Intensity| Intensity| Intensity| Red
2| Red| Red| | Green
3| Green| Green| Blue
4| Blue| Blue/Indigo*|
5| Strobe| Lime
6| | Strobe
- Original ColorSource PAR fixture uses blue in channel 4; Deep Blue fixture uses indigo in channel 4.
- Use DMX values of 0 or 255 for no strobe. Use values of 1–254 to increase the strobe rate from 1 per second up to 33 per second.
Data Loss Behavior
When DMX data is lost, the fixture does one of the following actions:
- If you selected a preset or sequence, that preset or sequence automatically plays.
- If no preset or sequence is active in the background, the fixture goes dark and the DMX start address flashes on the user interface.
Lock the User Interface
After you have set up the fixture, you can lock the user interface to
prevent additional changes.
- Press and hold the Up button and Down button simultaneously for 3 seconds. The display will show Loc to indicate that the user interface is locked.
- To unlock the user interface, press and hold the Up button and Down button simultaneously for 3 seconds.
Play Presets and Sequences
The fixture has twelve factory-configured presets and five factory-
configured sequences. When you play a preset or sequence on a fixture:
- The same preset number or sequence number plays on any connected fixtures that are not receiving DMX.
- If you power down the fixture, the preset or sequence resumes when you power it on again.
You can re-record presets and sequences through an RDM device or manually on the fixture. See Re-record Presets on the next page.
- Press the Mode button to activate the Presets/Sequences menu. The last active preset or sequence plays automatically. (If DMX data is present, the current preset or sequence plays in the background and DMX data continues to take priority.)
- Press the Up button or Down button as needed to scroll through the available presets and sequences.
- To stop the selected preset or sequence, press the Mode button a second time. The display will revert to show the DMX start address.
Pre-configured Presets
Preset | Name |
---|---|
1 | 3200 K White |
2 | 5600 K White |
3 | Red |
4 | Green |
5 | Blue |
6 | Cyan |
7 | Magenta |
8 | Yellow |
9 | Orange |
10 | Light Yellow |
11 | Light Blue |
12 | Light Pink |
Pre-configured Sequences
Sequence | Name |
---|---|
1 | Rainbow Fast |
2 | Rainbow Slow |
3 | Warm Colors Fast |
4 | Cool Colors Fast |
5 | Random |
Re-record Presets
- Using DMX, set the desired levels for the new preset.
- Press the Mode button to access the Presets/Sequences menu.
- Press the Up button or Down button to navigate to the preset number that you want to re-record.
- Press and hold the Mode button for 3 seconds to confirm the preset selection. The user interface will show a 3-second countdown. The preset number blinks once to confirm that the preset has been recorded.
Note: When the fixture is in Direct mode (dir) or 1-channel mode (1ch),
you cannot re-record presets.
When you re-record presets with the fixture in RGB mode (rgb), the intensity
is set to full and the strobe is turned off.
See Change the DMX Control Mode on page 7.
Adjust the Intensity of Presets
- Ensure that DMX data is not present.
- Press the Mode button to access the Presets/Sequences menu, and then press the Up button or Down button to select the preset that you want to edit.
- Press and hold the Mode button for 3 seconds. The display shows L: followed by either an intensity level from 0– 99 or FL for full.
- Press the Up button or Down button to change the intensity level of the preset in real time.
- Press the Mode button to confirm your selection and return to
the Presets/Sequences menu. (If you don’t press the Mode button, the display returns to the Presets menu after 10 seconds without saving your changes.)
Troubleshooting
Update the Fixture Software
ETC recommends using UpdaterAtor software to manage software updates. For
information on UpdaterAtor, see the UpdaterAtor Software Quick Guide and the
UpdaterAtor Software Release Note, which you can download from
etcconnect.com.
You can push newer software versions from a connected fixture to selected
ColorSource fixtures (see table that follows). You can push newer software
versions from a connected fixture only on ColorSource fixtures running
software v1.3.0 or newer. Use UpdaterAtor to update individual fixtures
running versions older than v1.3.0.
Note: If you have other types of fixtures in your DMX run, you do not need to disconnect them before pushing the updated fixture software. The update process will ignore any other fixture types in the DMX run.
Note: Not sure what version of fixture software is installed? The version number appears on the display when the fixture powers up.
This fixture… | …can push software to these fixtures/releases when connected |
---|---|
CYC | Linear |
≤ v1.7 | v3.1 |
v2.0 | v3.0 |
CYC v1.7 or earlier | X |
CYC v3.1 | |
Linear v1.7 or earlier | X |
PAR v1.7 or earlier | X |
PAR v3.0 | |
PAR v4.0 | |
Spot v1.7 or earlier | X |
Spot v3.0 | |
Spot jr v2.0 | |
Spot jr v3.0 |
- Remove power and DMX In from the fixture that is running the software version that you want to push to other fixtures.
- Press and hold the Up button and Down button simultaneously while restoring power.
- The display shows Udt rdy to indicate the update mode is selected.
- Press the Mode button to start the update process.
- The first time that you push an updated software version, additional required files must be copied before the update can begin. The display alternates between Udt and c:XX to indicate the percentage complete while required data is copied.
- The display alternates between Udt and the percentage complete while updating the connected fixtures.
- The display blinks once to indicate that the update is complete.
- Reconnect DMX In on the fixture.
Restore Factory Defaults
Press and hold the Mode button, Up button, and Down button simultaneously for
5 seconds. The DMX start address will blink once to confirm that defaults have
been restored.
Error Codes
These error codes may display on the user interface.
-
CAL: Screen toggles between CAL and Err to indicate a problem with the color calibration. The fixture will need to be returned to the ETC factory; contact your local dealer to set up a repair.
-
OtP: Screen toggles between OtP and Err to indicate that the fixture has gone into over-temperature protection mode to avoid damaging the fixture. Once the fixture has self-cooled, the error will automatically clear. If the error does not clear, contact
ETC Technical Support (visit etcconnect.com/contactETC). -
No App: Screen toggles between no and APP to indicate that the upgraded fixtures have a software issue. Reload software to clear the error. If the error persists, contact ETC Technical Support (visit etcconnect.com/contactETC).
Specifications and Reference
For current and complete compliance and specifications, see the ColorSource PAR datasheet at etcconnect.com.
Environment
The ColorSource PAR operates in ambient temperatures of 0°C–40°C and comes
with a variable-speed fan. The ColorSource PAR is for indoor use only.
- Maximum recommended ambient operating temperature: Ta = 40°C (104°F)
- Maximum anticipated external surface temperature at 40°C ambient: Tmax = 80°C (176°F)
- External temperatures after 5 minutes of full-brightness operation at 25°C (77°F) ambient: 30°C (86°F)
- External Temperature (steady state achieved) at 25°C (77°F): 41°C (106°F)
Electrical
- Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.
- Maximum power consumption is 120 W.
- Up to 9 luminaires (15 A max) may be linked via power thru connector (10 luminaires total per circuit) when used with an R20 Relay Module or Unison Echo Relay Panel. Consult breaker trip curves when used with other equipment. Requires power from a non-dimmable source.
- Inrush:
- 12 0 V: 35 A (first half-cycle)
- 240 V: 49 A (first half-cycle)
Typical Power Consumption
| 100 V| 120 V| 230 V
---|---|---|---
Power| Current| Power| Current| Power| Current
Idle| 1.22 W| 0.03 A| 1.21 W| 0.03 A| 1.14 W| 0.03 A
Direct at Full| 107 W| 1.07 A| 106 W| 0.88 A| 104 W| 0.46 A
RDM Values
Parameter | Fixture | Value | Description |
---|---|---|---|
Manufacturer ID | All | 0x6574 | Electronic Theatre Controls |
Model ID | ColorSource PAR | 0x0201 | ColorSource PAR (v1.7), ColorSource PAR |
CPU2 (v3.0), or ColorSource PAR CPU3 (v4.0)
ColorSource PAR
Deep Blue| 0x0202| ColorSource PAR Deep Blue (v1.7), ColorSource PAR DB CPU2
(v3.0), or ColorSource PAR DB CPU3 (v4.0)
DMX Start Address| All| 0x00F0| Range = 1–512
DMX
Personality|
All
|
0x00E0
| 1 = 5 Channel
2 = Direct
3 = 1 Channel
4 = RGB
Output Frequency| All| 0x8123| 0 = Standard (1.2 kHz)
1 = High (25 kHz)
FCC Compliance
ColorSource PAR (For any FCC matters):
Electronic Theatre Controls, Inc.
3031 Pleasant View Road
Middleton, WI 53562
+1 608-831-4116
etcconnect.com
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received; including interference that may cause undesired operation.
Visit etcconnect.com/products for current and complete compliance information including FCC compliance.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. Any
modifications or changes to this product not expressly approved by Electronic.
Theatre Controls, Inc. could void the user’s authority to operate the product.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the
interference at their own expense.
References
- ETC - Theatre, Film, Studio and Architectural Lighting
- Contacting ETC
- Patents & Trademarks
- Explore ETC Products
- Home - Electronic Theatre Controls Inc
- Home - Electronic Theatre Controls Inc
- ETC - Theatre, Film, Studio and Architectural Lighting
- Contacting ETC
- Patents & Trademarks
- Explore ETC Products
- ColorSource PAR Documentation
- Entertainment Fixtures | ETC
- UpdaterAtor Software
- DMX Emergency Bypass Controller Documentation
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>