InfiRay AT30 Online Dual-Spectrum Thermal Camera
Introduction to IRay Technology
IRay Technology concentrates on developing infrared thermal imaging technologies and manufacturing relevant products, with completely independent intellectual property rights. IRay is committed to providing global customers with professional and competitive infrared thermal imaging products and solutions. The main products include IRFPA detectors, thermal imaging modules, and terminal thermal cameras and imagers.
With R&D personnel accounts for 48% of all employees, 787 intellectual property projects in terms of IRay have been authorized and accepted: 629 patented technologies authorized and accepted in China (including those for integrated circuit chips, MEMS sensors design and manufacture, Matrix III image algorithms and intelligent precise temperature measurement algorithms, etc.); 18 patented technologies authorized and accepted overseas; 101 software copyrights; and 39 integrated circuit layout designs.(The statistic data is up to August, 2021)
IRay products have been applied in various fields, including epidemic prevention and control, industrial thermography, security and fire control, night vision observation, automatic driving, Internet of Things, AI, and machine vision.
Legal Disclaimer
The thermal cameras manufactured by IRAY TECHNOLOGY are warranted for a period
of two-year and the accessories are warranted for a period of three-month form
the delivery date of the original purchase, provided such products have been
under normal storage, use and maintenance.
This warranty extends only to the original purchaser and is not transferable.
It is not applicable to any product that has be subjected to misuse, neglect,
accident or abnormal conditions of operation.
In the case of a defect in a product covered by this warranty, the product
must not be further used or maintained in order to prevent additional damage.
The purchaser shall promptly report any defect to IRAY TECHNOLOGY or this
warranty will not apply.
IRAY TECHNOLOGY will, at its option, repair or replace any such defective product free of charge if, upon inspection, the product or accessories prove to be defective, the user can contact with after-sales service department of IRAY TECHNOLOGY within the said warranty period.
Copyright
©IRay Technology Co., Ltd. 2022. All right reserved worldwide. All contents in
this manual, including words, pictures, images, etc., belong to IRAY
TECHNOLOGY CO., LTD. (Hereinafter referred to as “THE COMPANY” or “IRAY
TECHNOLOGY”). No part of the manual, in whole or in parts, may be copied,
photocopied, translated, or transmitted without the prior written permission
of IRAY TECHNOLOGY. This manual is used as a guide. The photos, graphics,
diagrams and illustrations provided in the manual are only used to explain,
which may be different from the specific product. Please refer to the real
object. We try our best to make sure the contents in this manual are accurate.
We do not provide any representations or warranties in this manual.
IRAY TECHNOLOGY reserve the right to update the manual. If you need the latest
version of this manual, please contact us. It is recommended that you use this
manual with the guidance of professionals.
Quality Assurance
The Quality Management System under which these products are developed and
manufactured has been certified in accordance with the ISO 9001 standard.
We reserve the right to make changes and improvements on any of the products
without prior notice.
Safety Information
WARNING
- Before using the cleanser, make sure you read all applicable material safety data sheets (MSDS) and warning labels on cleanser containers.
- Do not use too long screws when installing the front/rear mounting bracket, which may damage the thermal camera.
- It is prohibited to place the product in a high temperature above 70°C or in a low temperature below-45 °C.
- It is forbidden to disassemble or refit the thermal camera at will.
CAUTION
- No matter there is a lens cover or not, do not point the thermal camera towards strong light or equipment with laser radiation. This will affect the accuracy of the thermal camera and even damage the detector in the thermal camera.
- Do not use the product under conditions that doesn’t match the environmental requirements. For specific use environment requirements, see the product parameter table.
- Do not apply solvents or equivalent liquids to the camera, the cables, or other items.
- Be careful when you clean the infrared lenses. The lens has an anti-reflective coating which is easily damaged. Damage to the infrared lens can occur with too much force or cleaning with rough objects such as tissues.
Notice to user
-
Calibration
Annual calibration to the thermal camera is recommended to ensure the accuracy of temperature measurement, either through IRAY TECHNOLOGY or third-party organizations. -
Accuracy
For accurate measurement, it’s recommended that you use the thermal camera after it is stable for 30 minutes. -
Video Teaching
You can search for mount and use videos from our website. -
Documentation Update
Our manuals are updated several times per year, and we also issue product- critical notifications of changes on a regular basis. Please visit our website to access the latest manuals and notifications.
Product Introduction
Main Features
- Accurate temperature measurement
- Support PoE
- Bi-spectral display
- Support multi-protocol access to industrial or IoT systems
- Multi-functional web client
- Wi-Fi hotspot
- Compact size
Typical Applications
- Monitoring power distribution cabinet
- Monitoring warehouse
- Monitoring production line
Please follow the steps:
- After installing the thermal camera in the desired position, use the cable to connect the thermal camera and the computer correctly. There are two power supply methods for AT30. Connect the device to the PoE port of the power supply through the M12 8-pin adapter cable or connect to the DC power supply through the M12 12- pin adapter cable. Connect AT30 to the network, and wait for 2 minutes after powering on. The power indicator light is steady blue and the network indicator light flashes green, indicating that the network connection is normal.
- Modify the computer network segment to be the same with that of thermal camera.
The specific path is “Control Panel”-“Network and Internet”-“Network and Sharing Center”-“Change Adapter Options”-“Ethernet”-“Properties”-“Internet Protocol Version 4 (TCP/IPv4)” – “Use the following IP address”-set the IP address to 192.168.1.xxx.
Product and Accessories List
Product and Accessories
- AT30 online dual-spectrum thermal camera
- M12 8-pin adapter cable
- Fixing accessories (screws, mounting stickers)
Optional Accessories
- M12 12-pin adapter cable &alarm input/output cable
- front/rear mounting bracket
Mechanical Installation
The front and back of the thermal camera are equipped with mounting interfaces, which can be installed with screws after the holes are punched with the auxiliary stickers in the package. In addition, we also provide two optional forms of front and back installation.
WARNING
- Do not use too long screws in case of damaging the thermal camera.
- The maximum hole depth of the front shell is 10mm, and the maximum hole depth of the rear shell is 4mm.
It’s normal that the thermal camera will generate heat during operation. In order to sufficiently dissipate the heat, it is suggested that the back shell of the thermal camera should be fixed on a metal object to minimize the temperature drift of the infrared detector in thermal camera.
Installing Shells with Screws
As shown in Figure 7.1, please paste the sticker to the position to be
installed, and then punch 4 Φ2.5 mounting holes according to the label on the
sticker, and use 4 M2 screws to install the front shell.
Front Mounting
There are four M4 threaded holes on the front mounting bracket for fixing.
Install the front mounting bracket
As shown in Figure 7.2, connect the front mounting bracket and the thermal
camera with ST2.2*8 self-tapping screws. The installation effect is shown in
Figure 7.3.
Punch holes
As shown in Figure 7.4, please paste the sticker to the position to be
installed, and then punch four Φ4.5 mounting holes according to the label on
the sticker.
Install the thermal came ra
As shown in Figure 7.4, use M4 screws to install the thermal camera to the
designated location.
Rear Mounting
There are four M4 threaded holes on the rear mounting bracket for fixing.
Step 1 Install the rear mounting bracket
As shown in Figure 7.5, connect the rear mounting bracket and the thermal
camera with M2*6 screws. The effect installation is shown in Figure 7.6
Step 2 Punch holes
As shown in Figure 7.7, please paste the sticker to the position to be
installed, and then punch four Φ4.5 mounting holes according to the label on
the sticker.
Step 3 Install the thermal camera
As shown in Figure7.7, use M4 screws to install the thermal camera to the
designated location.
Alarm Input and Output
-
Alarm Input
Support 1-ch active alarm input (switch value, photoelectric isolation). -
Alarm Output
Support 2-ch alarm outputs (switch value, photoelectric isolation), 3~25VDC, maximum 85mA.
Technical Data
Imaging and Optical Data
Infrared
| Resolution| 384×288
NETD| 40mK
Frequency| 25Hz
Lens| 3.8mm
FOV| 68.0°×51.8°
Focus| Focus free
Visible Light
| Visible Light Pixels| 2 MP
FOV| 81°×61°
Supplement Light| LED
Detector Data
Detector Type| VOx, Uncooled FPA detector
Spectral Range| 8~14μm
Pixel| 12μm
Temperature Measurement
Object Temperature Range| -20~650℃
Accuracy| ±2℃ or ±2%, the larger value shall prevail
Spot/Line/Area| maximum 8 spots/8 lines/8 areas
Palette| 20
Environment Variable Correction
| ****
distance, atmospheric temperature, emissivity, reflection temperature, atmospheric transmittance
---|---
Alarm
Alarm Function
| ****
The highest temperature, lowest temperature and average temperature in all temperature measurement points, temperature measurement areas and lines can be configured with separate alarm outputs.
Alarm Input/Output
| ****
1-ch alarm input; 2-ch alarm out
Other alarms: save image/video, sending file (FTP), email (SMTP), and flash alarm.
Ethernet
Ethernet Functions| control, imaging and power supply
Ethernet Connector Type| RJ45/ Wi-Fi/ Hotspot
Ethernet Power Supply| Support PoE
Network Protocol| TCP,UDP,RTSP,HTTP,SMTP
Interface Protocol| ONVIF,GB28181,Modbus TCP,MQTT
Image transmission
Image Stream
| Image Stream Format| H.264/H.265
Resolution
| visible light 1600×1200;
infrared 384×288, support super resolution up to Max. 1024×768
Image Mode
| thermal image, visual image, fusion, DDE, and parallel display of visual
images are supported.
Frame Rate Adjustment| supported
Data Stream
| ****
Data Stream Transmission
| Visible and thermal images, temperature stream, adjustable
frame rate
Image Storage
| Storage Medium| built-in 32GB storage
Storage Mode
| store thermal images and visible
images simultaneously.
File Format| JPG, MP4
Storage Form
| local storage, connected to
monitoring systems, such as NVR.
Typical Power Supply
External Power| 12~30V DC
PoE| IEEE 802.3af
Power Consumption| ≤2W
Environmental Data
Encapsulation
| ****
IP67
Operating Temperature Range
| ****
-10~50℃
Storage Temperature Range
| ****
-40~70℃
Humidity
| ****
≤95% (no condensation)
EMC
| ****
IEC 61000-4-2(anti-interference)
IEC 61000-4-3(anti-radiation)
Shock
| ****
25G,IEC68-2-29
Vibration
| ****
2G, IEC68-2-6
Physical Data
Dimension| 109×58×31mm
Weight| 191g
Housing Material
| Front shell is plastic and rear shell is
aluminum alloy.
Table 9.1 AT30 Performance Parameters
Others
Certification| CE/FCC/RoHS
SDK
| Cross-platform SDK for secondary
development.
External Interface
| M12, Type A ,8-pin, including 10M / 100M adaptive Ethernet port and PoE power supply;
M12, Type A, 12-pin, including DC power
supply, alarm input and output;
Pin Configuration for Interfaces
Ethernet Pin Configuration (8pin)
Pin | Configuration | Pin | Configuration |
---|
1
| ****
TX+
| ****
5
| ****
PD+
2
| ****
TX-
| ****
6
| ****
PD+
3
| ****
RX+
| ****
7
| ****
PD-
4
| ****
RX-
| ****
8
| ****
PD-
Power Pin Configuration (12pin)
Pin | Configuration | Pin | Configuration |
---|---|---|---|
1 | Power + | 7 | ALARM POWER2 |
2 | Power + | 8 | ALARM OUT2 |
3 | Power Ground | 9 | ALARM IN+ |
4 | Power Ground | 10 | ALARM IN- |
5 | ALARM_POWER1 | 11 | GND |
6 | ALARM_OUT1 | 12 | Video |
Mechanical Drawings
Common Troubleshooting
Troubles | Possible Cause | Solutions |
---|
Camera cannot be started.
| The supply voltage exceeds the normal working supply voltage
range.
| ****
Check whether the power supply voltage is between 12 and 30V
The power connector is loose.| Check whether the power cable is connected
Web cannot be logged in.
| ****
IP setting is wrong.
| Manually configure the
computer address to the 192.168.1.XX
Image is stuck.
| Network cable connection is loose.| After checking the network cable connection, restart the web.
Cleaning Thermal Camera
Camera Housing, Cables and Other Items
Liquids
| ****
One of the following liquids can be used. 1.Warm water
2. Neutral detergent solution
Cleaning Tools| A soft cloth
Cleaning Procedures
| Please follow this procedure: 1.Soak a soft cloth in the liquid.
2. Twist the cloth to remove excess liquid.
3. Clean the camera parts with the cloth.
Cleaning Infrared Lens
Liquids
| One of the following liquids can be used.
1.Commercial lens cleaning liquid with more than 30% is opropyl alcohol.
2.96% ethyl alcohol(C2H5OH).
---|---
Cleaning Tools| Dustless cloth, cotton wool
Cleaning Procedure
| ****
Please follow this procedure (Take dustless cloth as an example).
1.Soak the dustless cloth in the liquid. 2.Gently wipe the lens with the dustless cloth
CAUTION: The dustless cloth or cotton wool should be used one time only.
Appendix A Emissivity of Common Materials
Material | Temperature (℃) | Emissivity |
---|---|---|
Water | 0~100 | 0.95~0.98 |
Soil(dry) | 20 | 0.92 |
Soil(wet) | 20 | 0.95 |
Woods | 17 | 0.962 |
Sand | 20 | 0.9 |
Sandstone | 19 | 0.909~0.935 |
PVC plastic | 70 | 0.93 |
Asphalt | 20 | 0.967 |
Paint | 70 | 0.92~0.94 |
Wallpaper | 20 | 0.85~0.90 |
Cloth | 20 | 0.98 |
Concrete | 20 | 0.92 |
Pavement surface | 5 | 0.974 |
Smooth porcelain | 20 | 0.92 |
Ceramic tile | 17 | 0.94 |
Gypsum | 17 | 0.86 |
Bricks | 35 | 0.94 |
Hard rubber | 0~100 | 0.89 |
Charcoal | 20~400 | 0.95~0.97 |
Granite(rough) | 20 | 0.879 |
Cold rolled steel | 70 | 0.09 |
Oxidized steel | 50 | 0.88 |
Copper | 20 | 0.07 |
Oxidized copper | 50 | 0.6~0.7 |
FCC Statement
MODIFICATION: Any changes or modifications not expressly approved by the
grantee of this device could void the user’s authority to operate the device.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference,
- This device must accept any interfer-ence received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device should be installed and operated with minimum distance 7.9 inches (20 cm) be-tween the radiator & your body.
Worth comes from Service
- 24h Hotline400-998-3088
- Technical Support Hotline400-883-0800
IRay Technology Co., Ltd.
www.infiray.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>