Francotyp-Postalia FPi 5100 Folder Inserter Installation Guide

June 12, 2024
Francotyp-Postalia

FPi 5100 Folder Inserter

Product Information

The FPi 6100/7100/8100 Series Inserting System is a
high-performance machine designed for efficient and accurate
document insertion. It features a sealing solution bottle that
needs to be refilled when prompted by a warning message on the
display screen. The sealing solution helps ensure proper sealing
and secure closure of envelopes.

Sealing Solution Refill Instructions

  1. Open the Sealer bottle cover and remove the bottle from its
    holder on the system. Place the bottle on a flat surface.

  2. Unscrew the pressure-sensitive top and remove it from the
    bottle.

  3. Pour sealing solution into the bottle until it reaches the fill
    line.

  4. NOTE: Water can be used as an alternative to
    sealing solution but is not recommended due to potential bacterial
    growth that may affect the sealer’s performance.

  5. Screw the pressure-sensitive top securely back onto the
    bottle.

  6. Wipe off any excess fluid that may have spilled.

  7. Put the bottle back into the holder on the system.

  8. Close the Sealer cover.

NOTE: The first-time use of the sealing system
or situations where the wick has become dry may require a brief
waiting period to allow the wick to become moist.

For detailed information and further instructions, please refer
to the FPi 6100/7100/8100 Series Inserting System Operator Guide
available at
User-Guide-OG- FPi-5100-8100-EN.pdf
.

Run a Job | Operator Guide
Refill the Sealing Solution
A warning message appears on the display screen when it is time to replenish sealing solution in the sealer bottle : To refill the bottle: 1. Open the Sealer bottle cover and remove the bottle from its holder on
the system and place it on a flat surface. 2. Unscrew the pressure-sensitive top and remove it from the bottle. 3. Pour sealing solution into the bottle until it reaches the fill line.
NOTE: Water is an acceptable liquid to use in the Sealer, but is not recommended. The use of water can result in bacterial growth that can inhibit the performance of the sealer. 4. Screw the pressure-sensitive top securely back onto the bottle. 5. Wipe off any excess fluid that may have spilled. 6. Put the bottle back into the holder and close the Sealer cover.
NOTE: First time use of the sealing system, as well as situations in which the wick has become dry, will require a brief waiting period to allow the wick to get moist.

09/2022

Francotyp-Postalia GmbH | FPi 5100/6100/7100/8100 Series | P-FP63136_EN; Rev. 00 3-35 FP. (2022b, September). FPi 6100/7100/8100 Series Inserting System Operator Guide. FPi 6130 Support.