PCE-SC 10 Sound Level Meter Calibrator User Manual

June 12, 2024
PCE

10 Sound Level Meter Calibrator
User Manual

User Manual
Sound Level Meter Calibrator PCE-SC 10

Safety notes

Please read this manual carefully and completely before you use the device for the first time.
The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight,  extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.

We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Introduction

The PCE-SC 10 is a class 1 acoustic calibrator used for the calibration of microphones, sound pressure level (SPL) meters and other noise meters. The sound calibrator is suitable for use with type 1 or class I noise measuring instruments.  This portable decibel (db) meter calibrator is easy to use in the field or in laboratories.

Applications

– Calibration of microphones, sound level meters and other sound measurement equipment
– Check the linearity of the equipment to be calibrated

Features

  • Complies with IEC60942:2003 Class 1, ANSI S1.40-1984 and GB/T 15173-1994
  • 1 kHz calibration frequency for all weighting networks
  • Dual 94 & 114 dB sound pressure level outputs
  • Calibration accuracy ± 0.3 dB
  • Highly stable level and frequency
  • Easy 2-key operation
  • Fits 1/2” microphones and 1/4” microphones (with adaptor)
  • Powered by 2×AA batteries and automatic power off to conserve battery life

Functional block diagram

PCE SC 10 Sound Level Meter Calibrator - block diagram

Information on calibration principle

The PCE-SC 10 sound calibrator is a battery operated sound source for quick and direct calibration of sound level meters and other sound measuring systems. It fits 1/2” microphones and 1/4” microphones (with adaptors). The calibration frequency is 1000 Hz, which is the reference frequency for the standardized international weighting networks. That enables you to use the calibrator for calibrating sound equipment with A, B, C, D weighting filters and linear.  The calibration pressure is 94 ±0.3 dB (1 Pa) and 114 ±0.3 dB (10 Pa). The PCE-SC 10 is equipped with a feed‐back arrangement to ensure a highly stable sound pressure level. The feed‐back loop contains a reference microphone, a sound  source and control circuit. The reference microphone has passed a long-term aging test and has proved to be extremely stable. The feed‐back control circuit can adjust for changes in load volume, temperature, humidity and atmospheric  pressure. The calibrator gives a continuous sound pressure level when fitted onto a microphone and detects when the microphone is removed from the cavity and automatically switched off, thereby extending the battery life. When the  ON/OFF light flashes, this means that the battery voltage is low. If the device stops working continuously, the batteries must be replaced.

Operation

  • Pull down the battery compartment cover and insert the batteries. Make sure the polarity is correct.
  • Switch on the calibrator as well as the device to be calibrated (On / off key). Set either 94 or 114 dB, using the change key.
  • Place the aperture of the calibrator on the microphone (use the adaptor if applicable).
  • A value now appears in the display of the sound level meter. When this value has stabilised, turn the calibration screw to adjust the value accordingly.

Technical specifications

Frequency 1 kHz / ±0.5 %
Sound pressure levels 94 dB and 114 dB
Accuracy ±0.3 dB
Sound distortion <2 %
Stabilization time <10 s
Microphone aperture 1/2″ and 1/4″ according to IEC 61094-4
Operating conditions -10 … +50 °C (+10 … +122 °F) 10 … 90 % RH
Power supply 2 x 1.5 V AA batteries (LR6)
Dimensions 75 x 70 x 46 mm (2.96 x 2.76 x 1.82″)
Weight 316 g (0.7 lb)

Delivery contents

1 x sound calibrator PCE-SC 10
2 x 1.5 V AA battery (LR6)
1 x adaptor

Contact

If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices  should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.

www.pce-instruments.com PCE SC 10 Sound
Level Meter Calibrator - qr codehttp://www.pce-instruments.com

User manuals in various languages   can be found by using our product search on: www.pce-instruments.com

PCE Instruments contact information

Germany
PCE Deutschland GmbH
Im Langel 4
D-59872 Meschede
Deutschland
Tel.: +49 (0) 2903 976 99 0
Fax: +49 (0) 2903 976 99 29
[email protected]
www.pce-instruments.com/deutsch| France
PCE Instruments France EURL
23, rue de Strasbourg
67250 SOULTZ-SOUS-FORETS
France
Téléphone: +33 (0) 972 3537 17
Numéro de fax: +33 (0) 972 3537 18
[email protected]
www.pce-instruments.com/french| Spain
PCE Ibérica S.L.
Calle Mayor, 53
02500 Tobarra (Albacete)
España
Tel. : +34 967 543 548
Fax: +34 967 543 542
[email protected]
www.pce-instruments.com/espanol
---|---|---
United States of America
PCE Americas Inc.
711 Commerce Way suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 561-320-9162
Fax: +1 561-320-9176
[email protected]
www.pce-instruments.com/us| United Kingdom
PCE Instruments UK Ltd
Units 12/13 Southpoint Business Park
Ensign Way, Southampton
Hampshire
United Kingdom, SO31 4RF
Tel: +44 (0) 2380 98703 0
Fax: +44 (0) 2380 98703 9
[email protected]
www.pce-instruments.com/english| Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B-Interno 6
55010 LOC. GRAGNANO
CAPANNORI (LUCCA)
Italia
Telefono: +39 0583 975 114
Fax: +39 0583 974 824
[email protected]
www.pce-instruments.com/italiano
The Netherlands
PCE Brookhuis B.V.
Institutenweg 15
7521 PH Enschede
Nederland
Telefoon: +31 (0)53 737 01 92
Fax: +31 53 430 36 46
[email protected]
www.pce-instruments.com/dutch| Chile
PCE Instruments Chile S.A.
RUT: 76.154.057-2
Santos Dumont 738, local 4
Comuna de Recoleta, Santiago, Chile
Tel. : +56 2 24053238
Fax: +56 2 2873 3777
[email protected]
www.pce-instruments.com/chile| Hong Kong
PCE Instruments HK Ltd.
Unit J, 21/F., COS Centre
56 Tsun Yip Street
Kwun Tong
Kowloon, Hong Kong
Tel: +852-301-84912
[email protected]
www.pce-instruments.cn
China
PCE (Beijing) Technology Co.,Ltd
1519 Room, 6 Building
Men Tou Gou Xin Cheng,
Men Tou Gou District
102300 Beijing
China
Tel: +86 (10) 8893 9660
[email protected]
www.pce-instruments.cn| Turkey
PCE Teknik Cihazları Ltd.Şti.
Halkalı Merkez Mah.
Pehlivan Sok. No.6/C
34303 Küçükçekmece – İstanbul
Türkiye
Tel: 0212 471 11 47
Faks: 0212 705 53 93
[email protected]
www.pce-instruments.com/turkish|

Last change: 8 February 2018
v1.0
© PCE Instruments

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PCE User Manuals

Related Manuals