Explanation of symbols and safety instructions

1.1 Explanation of symbols
Warnings
In warnings, signal words at the beginning of a warning are used to indicate the type and seriousness of the ensuing risk if measures for minimizing danger are not taken.
The following signal words are defined and can be used in this document:

DANGER
DANGER indicates that severe or life-threatening personal injury will occur.
WARNING

WARNING indicates that severe to life-threatening personal injury may occur.

CAUTION
CAUTION indicates that minor to medium personal injury may occur.

NOTICE
NOTICE indicates that material damage may occur.

Important information

The info symbol indicates important information where there is no risk to people or property.

Symbol Meaning
**** Warning regarding flammable substances: the R32 refrigerant used in

this product is a gas with mild combustibility and low toxicity (A2L or A2).
| Maintenance by a qualified person should be done while following the instructions of the service manual.
| For operation follow the operating instructions for users.

Table 1

1.2 General safety instructions

Notices for the target group
These operating instructions are intended for the operator of the air conditioning system. All system relevant instructions must be observed. Failure to comply with instructions may result in material damage and personal injury, including danger to life.
▶ Read and retain the operating instructions of all system components prior to use.
▶ Observe the safety instructions and warnings.

Intended use
The indoor unit is intended for installation inside the building with connection to an outdoor unit and further system components, e.g. controls.
The outdoor unit is intended for installation outside the building with connection to an indoor unit or units and further system components, e.g. controls.
Any other use is considered inappropriate. Any damage that may result from misuse is excluded from liability.
For installation at special locations (underground garage, mechanical rooms, balcony or at any semi open areas):
▶ First refer to the requirements for the installation site in the technical documentation.

General dangers posed by the refrigerant
▶ This appliance is filled with refrigerant. If the refrigerant gas gets into contact with fire, it may generate toxic gas.
▶ Have the system inspected and serviced regularly by an approved contractor.
▶ If there is a possibility that refrigerant has escaped, thoroughly ventilate the room and notify the approved contractor.

Conversion and repairs
If modifications to the air conditioning system are not carried out correctly, this can result in personal injury and/or material damage.
▶ Have work carried out only by an approved contractor.
▶ Do not make any changes to the outdoor unit, indoor unit or other parts of the air conditioning system.
▶ Disconnect the air conditioning system from the power supply before carrying out any maintenance work.|
Notices on handling the system
If the air conditioning system is used incorrectly, this could impair your health.
▶ Do not stand directly in the airflow for any length of time.
▶ Ensure that the room temperature is suitable for all people in the room, including babies, children, elderly, bedridden or disabled people.
▶ Never insert objects into the unit, you could injure yourself.
If the unit is handled incorrectly, this can lead to reduced performance and also damage to the unit and personal injury.
▶ Do not block the air inlets and outlets of the unit.
▶ Shut doors and windows when the unit is in operation.
▶ Protect the indoor unit from water ingress.
▶ Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place.
▶ Do not apply any weight to the outdoor unit, e.g. objects or persons.
▶ Keep dust, steam and moisture in the installation room of the indoor unit to a minimum.
▶ Do not use highly-flammable gases, e.g. from spray cans, in the vicinity of the units.
▶ If there appears to be something wrong with the air conditioner (burning smell or faulty cable for example), stop using it immediately and disconnect the power supply.
Safety of electrical devices for domestic use and similar purposes
The following requirements apply in accordance with EN 60335-1 in order to prevent hazards from occurring when using electrical appliances:
“This appliance can be used by children of 8 years and older, as well as by people with reduced physical, sensory or mental capabilities or lacking in experience and knowledge, if they are supervised and have been given instruction in the  safe use of the appliance and understand the resulting dangers. Children shall not play with the appliance. Cleaning and user maintenance must not be performed by children without supervision.”
“If the power cable is damaged, it must  be replaced by the manufacturer, its customer service department or a similarly qualified person, so that risks are avoided.”
1.3 Notices regarding these instructions
The figures are shown together at the end of these instructions. The text contains references to the figures.
Depending on the model, the products may be different to those shown in these instructions.

Product Information

Declaration of conformity
The design and operating characteristics of this product comply with the European and national requirements.
The CE marking declares that the product complies with all the applicable EU legislation, which is stipulated by attaching this marking.
The complete text of the Declaration of Conformity is available on the Internet: worcester-bosch.co.uk.

2.2 Specifications of remote control

Power supply 2 AAA batteries
Signal range 8 m
Permissible ambient temperature –5 °C … 60 °C

Table 2

2.3 Usage with multi-split air conditioner
The indoor unit can be used in a system with multi-split air conditioner.
In this case, the following functions are disabled:

  • Energy saving functions ECO and GEAR
  • Self-cleaning (I clean)
  • Noise reduction (Silent Mode)
  • Manual operation
  • Refrigerant Leak Detection
  • Automatic energy-saving mode when on standby mode (1 W standby)

2.4 Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The device is hermetically closed. The following information on the refrigerant complies with the requirements of EU Regulation No 517/ 2014 on fluorinated greenhouse gases.

Information for the operator: If your installer refills refrigerant, he enters the additional fill volume and the total amount of the refrigerant in the following table.

Product type| N. cooling
capacity
[kW]| N. cooling
capacity
[kW]| Refrigerant
type| Global
warming
potential
(GWP)
[kgCo2 eq.]| Co2 equivalent
of original
charge size| Original
charge size
[kg]| Additional
charge size
[kg]| Total charge size
at commissioning
[kg]
---|---|---|---|---|---|---|---|---
CL5000i 26 E| 2,64| 2,93| R32| 675| 0,42| 0,62| (pipe length-5)
0.012|
CL5000i 35 E| 3,52| 3,81| R32| 675| 0,42| 0,62| (pipe length-5)
0.012|

Table 3 F-Gas data table

Operation

3.1 Indoor unit overview
Key to Fig. 1:

  1. Top panel
  2. Space for small filter
  3.  Air filter
  4. Back of the display
  5. Button for manual operation
  6. Airflow panel

Display of indoor unit

BOSCH CL5000iU W 26 E Split Air Conditioner - indoor

Symbol

| Explanation
---|---

Number

| Temperature display
| WLAN connections) active
| Displayed with some functions, if these are switched on. Indicates that the ON timer is active when the indoor unit is switched off.

OF

| Displayed with some functions, if these are switched off.

dF

| Automatic defrosting active

BP

| Frost protection active: the indoor unit keeps the room temperature at at least 8 °C.

CL

| The self-cleaning function is active (I clean)

Ex, Px, Fx

| Fault code (“x” stands for any digit).

  1. Only available as accessory with IP-Gateway.
    Table 4 Symbols in the display
    3.2 Remote control overview
    Keys on remote control

BOSCH CL5000iU W 26 E Split Air Conditioner - remote
control

Pos. Key Function
1 Switch on/off.
Mode Set operating mode
Eco operation mode
2 SET Select advanced operating functions
OK Confirm choice
Setting timer
Increase temperature
Reduce temperature
3 Fan speed
Swing Set swing function
Fresh Fresh air function (Ionizer)
Turbo Turbo cool/Turbo heat
LED Switch off display of indoor unit and alarm buzzer

(Mute Mode)
Clean| Self-cleaning (I clean)

Table 5 Keys on remote control
Remote control display

BOSCH CL5000iU W 26 E Split Air Conditioner - remote control
1

Pos. Symbol Explanation
1 Operating function: indirect airflow is active (Wind avoid me).
Infographic: self-cleaning is active (I clean).
Operating function: fresh air function is active

(Ionizer).
| Operating function: sleep mode is active.
| Operating function: follow me function is active (Follow Me); temperature measurement at the remote control.
| Infographic: wireless control function.
| Infographic: battery status
2| | Operating mode: automatic mode
| Operating mode: cooling mode
| Operating mode: dehumidification mode
| Operating mode: heating mode
| Operating mode: fan mode
3| | Value display: shows the set temperature, fan speed
or (when timer is activated) the timer setting as
standard.
| Infographic: transmission indicator, lights up when
the remote control sends a signal to the indoor unit.
| Infographic: energy saving function active.
GEAR| Infographic: energy saving function active.
| Infographic: ON/OFF timer active.
| Infographic: noise reduction is active (Silent Mode).
| Value display: shows the current fan speed. There are
several output stages (bars) and the AUTO setting for
automatic control.
4| | Infographic: automatic vertical swing function is
active (up/down). Alternatively, display of the current
position of the horizontal louver.
| Infographic: automatic horizontal swing function is
active (left/right).
| Infographic: Turbo cool/Turbo heat is active.

Table 6 Symbols in the display

3.3 Using the remote control
The signal range is 8 m. If objects are in the way or certain fluorescent lamps are used in the same room this can affect transmission of the signal.

  • Point the remote control towards the signal receiver window of the unit and press the desired key.

The unit emits a beep when it receives a signal.

NOTICE
The remote control may be permanently prevented from working correctly.

  • Do not expose the remote control to direct sunlight.
  • Do not leave the remote control near a heating appliance.
  • Protect the remote control from moisture and impacts.

3.4 Setting main operating mode
Switching on/off the unit

  • Pressthe K key to switch the unit on or off:

The unit starts in the set operating mode.
Settings can also be made when the unit is switched off. The unit saves the settings, and also retains them in the event of a power failure.
After turning off, the unit remains in standby mode. Intelligent on-off technology enables an automatic energy-saving mode when on standby mode (1 W standby).

Automatic mode
In automatic mode, the unit automatically switches between heating and cooling mode to maintain the desired temperature.

  • Press Mode key repeatedly until appears on the display.
  • Select the required temperature with the . and keys.

The fan speed cannot be adjusted in automatic mode.

Cooling mode

  • Press Mode key repeatedly until appears on the display.
  • Press the key until the required air speed is reached.
  • Select the required temperature with the . and / keys.

Fan (Only) mode

  • Press Mode key repeatedly until appears on the display.
  • Press the key until the required fan speed is reached. AUTO can be selected to enable automatic control.

The temperature cannot be adjusted or displayed in fan mode.

Troubleshooting

4.1 Faults with indication (Self diagnosis function)
If a fault occurs during operation, the LEDs flash for an extended period or an error code is displayed (e.g. EH 02).
If a fault is present for more than 10 minutes:
▶ Briefly disconnect the power supply and switch the indoor unit back on.

If a fault persists:
▶ Call customer service and provide the fault code and details of the appliance.

4.2 Faults without indication
If faults occur during operation that cannot be eliminated:
▶ Call customer service about the fault, providing details of the unit.

Fault Possible Cause
The output of the indoor unit is too low. Temperature is set too high or too

low.
Air filter is soiled and must be cleaned.
Unfavourable ambient conditions for the indoor unit, e.g. the ventilation openings of the units are obstructed, doors/windows in the room are open or the room contains powerful heat sources.
Low-noise operation is activated and prevents the full output from being used.
Indoor unit does not switch on.| The indoor unit has a safety mechanism to prevent overloading. It may take 3 minutes until the indoor unit can be restarted.
The batteries of the remote control are empty.
The timer is switched on.
Operating mode changes from Cooling or Heating to Fan Mode.| The indoor unit changes operating mode to prevent the formation of frost.
The set temperature is reached provisionally.
A white mist is coming from the indoor unit.| In humid regions, white mist may appear if there is a significant temperature difference between the indoor air and air-conditioned air.
White mist is emerging from the indoor unit and outdoor unit.| If heating mode is activated directly after automatic defrosting, this can generate white mist due to the higher level of humidity.
There is noise coming from the indoor unit and outdoor unit.| A swooshing noise may be heard inside the indoor unit if the position of the airflow grille is set back.
A quiet hissing noise is normal during operation. This is caused by the flow of refrigerant.
Creaks and squeaks may be heard, as the metal and plastic parts of the unit expand or contract during heating/cooling.
The outdoor unit also emits a range of other noises during operation which is normal.
Dust is being discharged from the indoor unit or outdoor unit.| Dust may accumulate in the units if they are shut down for an extended period and not covered.
Unpleasant odour during operation.| Unpleasant odours in the air may enter the units and spread.
There may be mould on the air filter and it must therefore be deaned.
The fan of the outdoor unit is not running continuously.| Variable fan control is used to ensure optimum operation.
Operation is irregular or unpredictable or the indoor unit is not responding.| The indoor unit may be affected by interference from mobile radio masts or external signal amplifiers.
►Briefly disconnect the indoor unit from the power supply then restart it. _
Air flow panel or louver is not moving correctly.| Air flow panel or louver has been adjusted manually or has not been correctly installed.
► Switch off the indoor unit and check whether the components are engaged correctly.
► Power on the indoor unit.

Maintenance

CAUTION
Danger due to electric shock or moving parts

  • Disconnect the power supply before carrying out any maintenance work.
  • Have any maintenance steps that are not listed here carried out by an approved contractor.

5.1 Replacing the batteries
You require 2 size AAA batteries. Using rechargeable batteries is not recommended.

  • Remove the battery cover (Fig. 2).
  • Insert new batteries, ensuring correct polarity.
  • Reinstall the cover.

5.2 Cleaning the unit and the remote control
NOTICE
Damage to unit due to incorrect cleaning!

  • Do not directly splash or pour water onto them.
  • Do not use hot water, thinner, abrasive powders or strong solvents.
  • Clean indoor unit and remote control by wiping them with a soft cloth.
  • Only have the outdoor unit cleaned by an approved contractor.

5.3 Cleaning the air filter
NOTICE
The air filter may deform in direct sunlight.

  • Do not expose the air filter to direct sunlight.
    Clean the air filter every 2 weeks, and also before and after decommissioning for longer periods.

  • Switch off the indoor unit.

  • Fold the top cover of the indoor unit up.

  • Push the air filter up and pull it out (Fig. 3).

  • Take out the small air filters, if installed (Fig. 1, [2]).

  • Clean the small air filters with a handheld vacuum cleaner.

  • Wash the large air filter with warm water and a mild cleaning agent and dry in the shade.

  • Reattach the small air filter and the large air filter.

5.4 Decommissioning for longer periods
Before decommissioning for longer periods:

  • Clean the air filter.
  • Activate the self-cleaning function using the Clean key.
  • After self-cleaning is complete, activate fan mode until the indoor unit is dry.
  • Switch off the indoor unit and disconnect it from the power supply.
  • Take batteries out of the remote control.
  • Protect the units from dust.

5.5 Manual operation
NOTICE
Damage to units due to incorrect operation
Use of manual operation on a continuous basis is not envisaged.

  • This must only be used for testing purposes or in emergencies.

  • Only use for a short time.

  • Switch off the indoor unit.

  • Fold the top cover of the indoor unit up.

  • Press the key for the manual cooling mode by inserting a thin object:
    – Press once: unit is forced into automatic mode.
    – Press twice: unit is forced into cooling mode.
    – Press three times: indoor unit is switched off.

  • Use remote control to restore normal mode.

Environmental protection and disposal

Environmental protection is a fundamental corporate strategy of the Bosch Group.
The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed.
We use the best possible technology and materials for protecting the environment taking account of economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific recycling processes that ensure optimum recycling.
All of our packaging materials are environmentally compatible and can be recycled.
Used appliances
Used appliances contain valuable materials that can be recycled.
The various assemblies can be easily dismantled. Synthetic materials are marked accordingly. Assemblies can therefore be sorted by composition and passed on for recycling or disposal.

Old electrical and electronic appliances
This symbol means that the product must not be disposed of with other waste, and instead must be taken to the waste collection points for treatment, collection, recycling and disposal.
The symbol is valid in countries where waste electrical and electronic equipment regulations apply, e.g. “European Directive 2012/19/EC on old electronic and electrical appliances”. These regulations define the framework for the return  and recycling of old electronic appliances that apply in each country.
As electronic devices may contain hazardous substances, it needs to be recycled responsibly in order to minimize any potential harm to the environment and human health. Furthermore, recycling of electronic scrap helps preserve natural resources.
For additional information on the environmentally compatible disposal of old electrical and electronic appliances, please contact the relevant local authorities, your household waste disposal service or the retailer where you purchased the product.
You can find more information here: www.weee.bosch- thermotechnology.com/

Batteries
Batteries must not be disposed together with your household waste.
Used batteries must be disposed of in local collection systems.
Refrigerant R32
The appliance contains fluorinated gas R32 (global warming potential 675 1) ) mild combustibility and low toxicity (A2L or A2).
Contained quantity is indicated on the equipment outdoor unit name label.
Refrigerant is hazardous to the environment and must be collected and disposed of separately.

Data Protection Notice

BOSCH CL5000iU W 26 E Split Air Conditioner - qr code1https://show-policy.ttprivacy.com/ol- 7de7b314-7e73-4248-bab1-8aabdc16c8f7?country=DE&lang=en-GB

We, Bosch Thermotechnology Ltd., Cotswold Way, Warndon, Worcester WR4 9SW, United Kingdom process product and installation information,  technical and connection data, communication data, product registration and client  history data to provide product functionality (art. 6 (1) sentence 1 (b) GDPR), to fulfil our duty of product surveillance and for product safety and security reasons (art. 6 (1) sentence 1 (f) GDPR), to safeguard our rights in connection with  warranty and product registration questions (art. 6 (1) sentence 1 (f) GDPR) and to analyze the distribution of our products and to provide individualized information and offers related to the product (art. 6 (1) sentence 1 (f) GDPR). To  provide services such as sales and marketing services, contract management, payment handling, programming, data hosting and hotline services we can commission and transfer data to external service providers and/or Bosch affiliated  enterprises. In some cases, but only if appropriate data protection is ensured, personal data might be transferred to recipients located outside of the European Economic Area. Further information are provided on request. You can contact  our Data Protection Officer under:
Data Protection Officer, Information Security and Privacy (C/ISP), Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY.
You have the right to object, on grounds relating to your particular situation or where personal data are processed for direct marketing purposes, at any time to processing of your personal data which is based on art. 6 (1) sentence 1 (f)  GDPR. To exercise your rights, please contact us via privacy.ttgb@bosch.com To find further information, please follow the QR-Code.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals