PCE-WSAC 50-ABC Weather Station User Manual

June 12, 2024
PCE

PCE-logo

PCE-WSAC 50-ABC Weather Station

Product Information

  • Product Name: PCE-WSAC 50 Windmesser
  • Voltage: 115 V AC, 230 V AC, 24 V DC
  • Measurement Range: 0-50 m/s
  • Output: 4-20 mA, 0-10 V
  • Relay: 2 x Wechsler 250 V AC / 10 A AC, 30 V DC / 10 A DC
  • Dimensions: Not specified

Product Usage Instructions

  1. Assembly: Follow the instructions provided in the user manual for proper assembly of the wind meter.
  2. Power Supply: Connect the wind meter to a power source with the specified voltage (115 V AC, 230 V AC, or 24 V DC).
  3. Connecting the Sensors: Connect the wind speed sensor to the wind meter according to the pin assignment described in the user manual.
  4. Measurement: Once the wind meter is properly set up and connected, it will start measuring the wind speed. The measured value will be displayed on the screen.
  5. Settings: Use the Enter and Arrow keys to navigate through the settings menu and make any necessary adjustments or configurations.
  6. RS-485 Interface (optional): If you want to use the RS-485 interface for communication, refer to the user manual for the communication protocol and standard settings. 7.

Warranty: For warranty information, refer to section 7 of the user manual. 8.
Disposal: Follow proper disposal procedures for this product as described in section 8 of the user manual.

Thank you for purchasing a wind speed alarm controller from PCE Instruments.

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.

We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Safety symbols
Safety-related instructions the non-observance of which can cause damage to the device or personal injury carry a safety symbol.

Symbol

|

Designation / description

---|---
| Warning: hazardous area

Non-observance can cause damage to the device and injuries to the user.

| Warning: electrical voltage

Non-observance can cause electric shock.

Specifications

Technical specifications

Power supply| 115 V AC

230 V AC

24 V DC

---|---
Supply voltage for sensors (output)| 24 V DC / 150 mA
Measurement range| 0 … 50 m/s
Resolution| 0.1 m/s
Accuracy| ±0.2 m/s
Signal input (selectable)| 4 … 20 mA

0 … 10 V

Alarm relay| 2 x changeover contact 250 V AC / 10 A AC

30 V DC / 10 A DC

Interface (optional)| RS 485
Operating temperature| -20 … 60 °C
Dimensions| 191 mm x 125 mm

Delivery contents

  • 1 x wind speed alarm controller PCE-WSAC 50
  • 1 x user manual

Order code
PCE-WSAC 50-ABC

Example: PCE-WSAC 50-111

  • Power supply 230 V AC
  • Signal input 4… 20 mA
  • Communication RS-485 interface

Accessories

  • PCE-WSAC 50-A1C:
    PCE-FST-200-201-I Wind speed sensor 0 … 50 m/s / Output 4…20 mA

  • PCE-WSAC 50-A2C:
    PCE-FST-200-201-U Wind speed sensor 0 … 50 m/s / Output 0…10 V

System description

Device descriptionPCE-WSAC-50-ABC-Weather-Station-fig
5

1 Opening groove 8 Arrow up key
2 LED „normal“ 9 Display wind scale (wind force)
3 LED „pre-alarm“ 10 Cable gland power supply
4 LED „alarm“ 11 Cable gland relay / wind sensor
5 Display measured value 12 Connection wind sensor
6 Enter key 13 RS-485 interface (optional)
7 Arrow right key

Electrical wiringPCE-WSAC-50-ABC-Weather-Station-fig
6

Pin assignment of „Signal Input“ plug

1| Vcc power supply output|
---|---|---
2| GND
3| Signal
4| Protective earth conductor

Pin assignment RS485 interface plug

1| B|
---|---|---
2| A
3| GND
|

Getting started

Assembly
Attach the wind speed alarm controller where desired. The dimensions can be taken from the assembly drawing below.PCE-WSAC-50-ABC-Weather-Station-fig
9

Power supply
Establish power supply by means of the relevant connections and set up the connection of the relay outputs to your system or signalling device (see 3.2). Make sure that the polarity and the power supply is correct.
ATTENTION: Excessive voltage can destroy the device! Ensure zero voltage when establishing the connection!

The device will power on immediately when connected to the power supply. The current reading will be displayed when a sensor has been connected. If no sensor has been attached, the display will show “00,0“ if you have one of the PCE-WSAC 50-A2C versions (signal input 0…10 V) or. “Err“ if you have a PCE- WSAC 50-A1C version (Signal input 4…20 mA).

Connecting the sensors
Connect the sensor (not included in the standard package) and the (optional) interface, using the plugs as described in 3.3 and 3.4. Make sure that the polarity and the power supply are correct.
ATTENTION: Non-observance of the polarity can destroy the wind speed alarm controller and the sensor.

Operation

Measurement

  • The device measures continuously as long as it is connected to the power supply. The factory default setting for the pre-alarm (S1) is from 8 m/s and for the alarm (S2), the default setting is from 10.8 m/s.
  • The pre-alarm will make the pre-alarm relay switch, a yellow LED will glow and a beep sound will be emitted in intervals.
  • In case of an alarm, the alarm relay will switch, the red LED will glow and a continuous beep sound will be activated.

Settings
To get to the setup menu, press the ENTER key (6) until the first digit flashes. Then enter “888“.
With the Arrow right key (7), you can navigate through the digits and change the value of the digit with the Arrow up key (8). Confirm with ENTER (6).
The following options can be selected using the Arrow up key (8):

Display Meaning Description
Ext Exit Back to normal measuring mode
S1 Pre-alarm Enter the desired value (max. 50 m/s). You can move the cursor

with the Arrow right key (7) and change the value of the digits with the Arrow up key (8). Confirm with ENTER (6).

Please note:

The pre-alarm value must not be higher than the alarm value and the alarm value must not be lower than the pre-

alarm value.

S2| Alarm| Enter the desired value (max. 50 m/s). You can move the cursor with the Arrow right key (7) and change the value of the digits with the Arrow up key (8). Confirm with ENTER (6).

Please note:

The pre-alarm value must not be higher than the alarm value and the alarm value must not be lower than the pre-

alarm value.

Flt| Filter| You can use the Arrow right key (7) to navigate through the digits and the Arrow up key (8) to change the value of the digits. Confirm with ENTER (6).

The following options can be selected: “000“ Current wind speed

Change interval of display:    200 ms Change interval of relay:        200 ms

“002“ 2-minute average value Change interval of display:    120 s Change interval of relay:        120 s

“005“ 5-minute average value Change interval of display:    300 s Change interval of relay:        300 s

Str| Factory settings| Resets all parameters to factory settings

To enter the relevant menu, select the menu with the Arrow up key (8) and confirm with ENTER (6).
You can leave the menu by selecting “Ext“ and confirming with the ENTER (6) key. If no key is pressed for 60 seconds, the device enters normal measuring mode automatically.

RS-485 interface (optional)
The communication with the wind speed alarm controller PCE-WSAC 50 is enabled by the MODBUS RTU protocol and the serial RS-485 port. This allows different registers containing the measured wind speed, the wind scale and other information to be read.

Communication protocol

  • The registers can be read by means of the Modbus function 03 (03 hex) and written into by the function 06 (06 hex).

Supported baud rates| 1200, 2400, 4800, 9600, 14400, 19200,

38400, 56000, 57600, 115200

---|---
Data bits| 8
Parity bit| None
Stop bits| 1 or 2
Data type of registers| 16-bit unsigned integer

Standard setting

Baud rate 9600
Parity None
Stop bit 1
Address 123

Excerpt from register addresses

Register address (dec)| Register address (hex)| Description| R/W
---|---|---|---
0000| 0000| Current wind speed in m/s| R
0001| 0001| Current wind scale| R
0034| 0022| Pre-alarm| R/W
0035| 0023| Alarm| R/W
0080| 0050| Modbus address| R/W
0081| 0051| Baud rate (12 = 1200 baud, 24 = 2400 baud,

etc.)

| R/W
0084| 0054| Stop bits (1 or 2)| R/W

Warranty

You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/agb.

Disposal

  • For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste.
  • They must be given to collection points designed for that purpose.
  • In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
  • For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
  • If you have any questions, please contact PCE Instruments.

Contact information

Germany

United States of America

China

United Kingdom

Turkey

can be downloaded here: www.pce-instruments.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals