AeroDioDE AOM Series Fiber Coupled and RF Drivers User Manual
- June 12, 2024
- AeroDioDE
Table of Contents
AeroDioDE AOM Series Fiber Coupled and RF Drivers User Manual
AeroDIODE – Institut d’optique d’Aquitaine – Rue François Mitterrand
33400 Talence – France – Tél.: +33 (0)6 27 69 41 62
www.AeroDIODE.com
Revision Sheet
Disclaimer : Information in this document is subject to change without notice.
Copyright © AeroDIODE
Bât. IOA, rue François Mitterrand
33400 Talence France
www.AeroDIODE.com
1. General information
Please read this manual carefully. It describes the hazard the user might be exposed to while using the product. It also explains in details how to use the product in the safest and most efficient possible way. The safety of any system incorporating the product is the responsibility of the assembler of the system. Any actions taken by the user that is not clearly described in this user manual might present a risk and is the sole responsibility of said user.
This product is to be used in laboratory or industrial tasks, and only by personnel who have followed a training in laser hazard.
This product is an OEM device for system integration. It is designed for use as a component (or replacement) part and is thereby exempt from 21 CFR1040.10 and 1040.11 provisions. Make sure it is not put in operation before the machine in which it will be integrated has been declared to be compliant with the relevant requirements of the current directives :
- 2006/25/CE (following for example the regulation NF EN 60825-1) (Europe)
- 21 CFR1040.10 and 1040.11 provisions (USA)
1.1 Definitions
Caution : A “caution” is advised when dealing with hazardous situations, tasks or objects, to prevent harm or death and avoid material damage or failure.
Warning : A “warning” is given for potentially dangerous situation for people which cause them harm or lead to death
Note : A note is a complementary piece of advice that must be acknowledged by the user.
1.2 General warning
Caution
The compatible laser sources used with the AOM can deliver up to several Watts
of coherent LASER radiation. Always wear protective goggles and observe the
safety instructions provided by the laser diode supplier when using the AOM
and/or AOM driver with your laser source.
WARNING
Do not try to open or remove the cover of the AOM or RF driver modules.
WARNING
Avoid all shocks and strains when handling the AOM
WARNING
Handle the fiber-optic cables with care as it is fragile. Do not bend or pinch
it.
WARNING
Any settings or hardware tinkering that is not described in this user manual
or in the usage recommendation may put the user or its environment at risk.
WARNING
The maintenance and servicing of the AOM should NOT be executed by the end
user : only AeroDIODE is able to maintain the AOM.
2. Safety Instructions
2.1. AOM Safety instruction
WARNING
Not following the safety recommendations and the caution mentioned above can
lead to eye damage.
2.2. RF Driver Safety instruction
Caution
Do not power up the signal output interface when it is open or shorted. Risk
of permanent damage.
Caution
The product should be well grounded, otherwise the performance can be
affected.
Caution
The product is sensitive to ESD.
2.3. Contact
If you have any question about the AOM module, please contact AeroDIODE : www.aerodiode.com
3. Package Content
The AOM modules comes with:
- 1 AOM module with 900 µm fiber and 2* FC/APC fiber connectors.
- A USB Key with the current user manual in pdf
The Driver part comes with :
- An SMA-SMA cable to connect the Driver to the AOM
- A special cable with Banana plugs to connect to a benchtop power supply
4. Absolute Maximum Ratings
4.1. AOM
- Optical power (CW) : refer to the AOM model Datasheet
- Storage temperature -40 to +85
- Operating temperature 0 to +60
- Caution : Applying a maximum RF power (voltage) above the maximum efficiency can lead to AOM permanent damage. As a first test level : a maximum RF power below 2W must be securely set.
4.2. RF Driver
- Operating voltage: +25V
- Control signal levels from 0 to +5.5V
- Storage temperature -40 to +85
- Operating temperature 0 to +60
5. Installation
5.1. AOM installation
- Wear safety Googles
- Wear a proper and working ESD wrist strap;
- Caution : Set the module on a heat dissipating surface (an optical table works fine). Letting the AOM in air with no dissipating surface leads to overheating and permanent damage.
- The light can be inserted in any direction. The performance are the same (insertion loss, extinction ratio etc.)
- Caution : when using another RF driver, The RF power shall not be set over the maximum diffraction efficiency level. A power over 2W can lead to a permanent damage. The RF power must be adjusted progressively from 0 V up to the maximum diffraction level.
5.2. RF Driver installation
The product is dissipated by conducting heat. The product shall be mounted on a metal structure using fixing screws. The mounting surface shall be flat with minimum size and thickness. A certain amount of space should be reserved around and above the product.
The product is powered by a DC of + 24V, and the power connector is supplied with a per-centric capacitor; The core of the heart capacitor is connected to the positive power supply, and the grounding sheet of the heart capacitor is connected to the negative pole of the power supply. The characteristic impedance of the product signal output port is 50 .
The product receives both external pure analog and/or digital modulation.
The adjustment of RF output power is achieved by changing the resistance of a multi-turner : turn clockwise to increase the output power, turn counterclockwise to decrease the output power.
-
Make sure the RF Driver has the correct RF frequency required by the AOM model (model 1 : 100 MHz, model 2 : 200 MHz, model 3 : 80 MHz ; model 4 : 200 MHz).
-
Make sure the RF Driver model is the one you need (TTL input or Analog input).
-
Connect the RF driver to the AOM with the SMA cable. If you use the modular model RFAOM-TA-200, set the S1-S4 switch to the proper configuration (see below )
-
Caution : Place the module on a heat dissipating surface (an optical table works fine).
Letting the RF driver in air with no dissipating surface leads to overheating and permanent damage. -
Connect a 24V >0.5A power supply to the RF driver
-
Caution : The RF power shall not be set over the maximum diffraction efficiency level. A power over 2W rapidly leads to a permanent damage. The RF drivers power level (little screw) is normally set in a safe area allowing a correct diffraction efficiency. If ever it is adjusted, this must be done progressively from 0 V up to the maximum diffraction level.
-
Connect the trigger signal and make sure you apply the good electric signal :
- TTL 5V-50 Ohm for standard RF-AOM-T-xxx model,
- Analog 0-5V signal for RF-AOM-A-xxx
- Any signal (0-5V or 0.1V) for the modular RFAOM-TA-200 model
-
If you need to optimize the insertion loss, apply a small optical CW signal at the proper wavelength and apply a CW trigger signal to the RF Driver. Use a screwdriver (Ø 3mm Multiturn) to adjust the RF power to get maximum optical power at the output of the AOM.
Figure 1 Example of integration of standard model (either RF_AOM-T-xxx or RF_AOM-A-xxx ) at either 80, 100 or 200 MHz :
Figure 2 : Model RFAOM-TA-200 S1-S4 settings
RFAOM-TA-200 Configuration switch :
- S1Down : TTL high ; Up : TTL low input signal configuration setting
- S2Down : TTL mode active ; Up : TTL mode disabled
- S3Down : Analog input range : 0 -1V ; Up : Analog input range 0 – 5V.
- S4Down : Analog mode active ; Up : Analog mode disabled
6. Specifications
6.1. AOM Modules :
6.2. RF Drivers :
References
- Your solution for laser diodes and photonics systems | AeroDIODE
- Your solution for laser diodes and photonics systems | AeroDIODE
- Fiber Modulator : How to choose the good technology ? Fiber Modulator Basics
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>