XPR Group B100PAD-SA v2 Standalone Biometric Reader Instruction Manual
- June 12, 2024
- XPR Group
Table of Contents
- XPR Group B100PAD-SA v2 Standalone Biometric Reader
- Product Information
- Product Usage Instructions
- INTRODUCTION
- MOUNTING
- SPECIFICATIONS
- APPLICATION DIAGRAM
- RECOMMENDED SWIPING TECHNIQUE
- INDICATION
- WIRING
- ADDING ADMIN FINGER
- PAIRING – BIOMETRIC READER AND REMOTE RELAY UNIT
- ADMINISTRATOR PROGRAMMING BY FINGER
- ADMINISTRATOR PROGRAMMING BY KEYPAD
- INSTALLER PROGRAMMING BY KEYPAD
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
XPR Group B100PAD-SA v2 Standalone Biometric Reader
Product Information
- Product Name: B100PAD-SA v2
- Product Type: Standalone Biometric Reader
- Manufacturer: XPR Group
- Website: www.xprgroup.com
- Revision: 1.01 – 06.04.2022
Product Usage Instructions
Mounting
To mount the device, follow these steps:
- Choose a suitable location away from strong electromagnetic fields and heating equipment.
- Clean the device using a soft cloth or towel. Do not spray or splash water or cleaning liquids on the device.
- Ensure that children do not touch the device without supervision.
Specifications
- Fingerprint Capacity: [Provide the fingerprint capacity]
- PIN Code Capacity: [Provide the PIN code capacity]
- Output: [Provide the output specifications]
- Panel Connection: [Provide the panel connection specifications]
- Push Button Input: [Provide the push button input specifications]
- Door Open Time: [Provide the door open time specifications]
- Entry Mode: [Provide the entry mode specifications]
- Programming: [Provide the programming specifications]
- Master/Admin Fingers: [Provide the master/admin fingers specifications]
- Backlight ON/OFF: [Provide the backlight ON/OFF specifications]
- Buzzer ON/OFF: [Provide the buzzer ON/OFF specifications]
- Firmware Upgrade: [Provide the firmware upgrade specifications]
- Current Consumption: [Provide the current consumption specifications]
- Power Supply: [Provide the power supply specifications]
- Indication: [Provide the indication specifications]
- IP Factor: [Provide the IP factor specifications]
- Operating Temperature: [Provide the operating temperature specifications]
- Operating Humidity: [Provide the operating humidity specifications]
- Dimensions(mm): [Provide the dimensions specifications]
Note: Please refer to the complete user manual for detailed instructions on wiring, pairing with remote relay units, administrator programming, installer programming, and usage of keypad.
INTRODUCTION
B100PAD-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance
in the way finger is swiped over the sensor reducing to minimum the need to
repeat finger swiping at the sensor.
The reader can store up to 99 finger templates. One template is reserved for
User manager (Administrator), one template is reserved for Reader
configuration (Installer) and up to 97 templates are for Users.
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are
devices with relays compatible with this reader that can increase the security
of the system if needed. One or two enrolled fingers are enough for one user.
Ask the installer before he leaves the site to enroll your finger as
administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger.
Some of the users may have very flat fingertips, making difficult for the
sensor to recognize correctly the fingerprint. In most cases, these are
children and older persons. To solve this problem, do the following:
- Try with different user’s fingers to find the “best” finger.
- Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use
soft wet cloth and wipe gently the dirt. Do not use chemicals and materials
that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash
with water or other liquids. When painting or construction work is ongoing in
the area around the reader, protect the reader sensor area from possible
damages and paint. If reader is to be dismounted or relocated, call authorized
installer for the job. Disposal of this product must be handled according to
all national laws and regulations.
MOUNTING
Do not install the device and cabling close to a source of strong electro-
magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe
it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the
surface will be damaged and the fingerprint can’t be entered.
The operating temperature of the product is between 0ºC – + 50ºC. XPR™ cannot
guarantee the functionality of the product if measures and advice before are
not followed.
SPECIFICATIONS
- Fingerprint Capacity: 97 templates
- PIN Code Capacity: 97 PIN Codes (1 to 8 digits)
- Output: 1 x Relay (2A/24V AC/DC)
- Panel Connection: Cable, 0.5 m
- Push Button Input: Yes
- Door Open Time: Pulse (1 to 30 seconds) or Toggle(ON/OFF)
- Entry Mode: Finger or Access Code
- Programming: By swiping or by keypad
- Master/Admin Fingers: 1 Administrator and 1 Installer Finger
- Backlight ON/OFF: Yes
- Buzzer ON/OFF: Yes
- Firmware upgrade: Via RS-485 converter and windows application
- Current Consumption: 150 mA max.
- Power Supply: 9-14 V DC
- Indication: Tricolor Status LED
- IP Factor: IP54 (internal use only)
- Operating Temperature : 0ºC to 50ºC
- Operating Humidity: 5% to 95% RH without condensation
- Dimensions(mm): 100 x 94 x 30
APPLICATION DIAGRAM
RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
- For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
- For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
INDICATION
WIRING
Wiring B100PAD-SA v2 with magnetic lock
Wiring B100PAD-SA v2 with electric strike
ADDING ADMIN FINGER
- Push dip switch no.2 in position ON.
- Reset the Power of the device.
- Wait for One long + multiple short beeps
- Put the dip switch in position OFF. (short beeps will stop)
- Wait for about 15 seconds for the LED to blink in Orange.
- Swipe the Master finger min.6 times. (Until Ok Beep)
Warning: This procedure also deletes all the users, the installer’s
finger, installer’s PIN Code and admin’s PIN Code.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT
or RU2)
PAIRING – BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of request-to-exit push button. Follow the instructions bellow to pair (couple) both devices or refer to the Remote Relay’s Manual.
Pairing B100PAD-SA v2 with DINRTT
- Close the Jumper. DINRTT beeps continuously and the red led blinks.
- Open the Jumper
- Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing B100PAD-SA v2 with RTT
- Put Dipswitch No.1 to position ON. RTT beeps continuously and the red led blinks.
- Put Dipswitch No.1 to position OFF.
- Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing B100PAD-SA v2 with RU2
- Put the Jumper to closed position. RU2 beeps continuously and the red led blinks.
- Put the Jumper to open position.
- Wait for Beep + OK Beep (short + short + long beep)
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
ADMINISTRATOR PROGRAMMING BY FINGER
Use point fingers as Administrator and Installer. You can use the other
fingers as access fingers.
Administrator finger is enrolled at the end of the system installation.
Initial enrollment of the Admin finger is described in installer manual.
ADD Finger Relay 1 (Finger that will activate relay 1)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 1 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger min. 6 times (until short + long beep) | fast blinking |
short + long beep
ADD Finger Relay 2 (Finger that will activate relay 2)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 2 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger min. 6 times (until short + long beep) | fast blinking |
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1 &2 (Finger that will activate relay 1&2)
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 3 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger min. 6 times (until short + long beep) | fast blinking |
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
DELETE Finger
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 4 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe User Finger | fast blinking | short + long beep |
DELETE ALL Fingers
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 4 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | slow blinking | short beep | |
Swipe Admin Finger 2 times | fast blinking | multiple beeps |
CHANGE ADMIN Finger
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 5 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | slow blinking | short beep | |
Swipe NEW Admin Finger min.6 times | fast blinking | short + long beep |
CHANGE/Enroll INSTALLER Finger
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Admin Finger 6 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | slow blinking | short + long beep | |
Swipe NEW Installer Finger min.6 times | fast blinking | 3 short beeps |
Administrator Programming block diagram
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
INSTALLER PROGRAMMING BY FINGER
Set Relay 1 Time (on board )
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 1 time | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe the INSTALLER Finger and start counting seconds | fast blinking | beeps |
on 1 second
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in
toggle mode| | ****
fast blinking
| ****
short + long beep
Set Relay 2 Time
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 2 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe the INSTALLER Finger and start counting seconds | fast blinking | beeps |
on 1 second
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in
toggle mode| | ****
fast blinking
| ****
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
BUZZER ON/OFF
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 3 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe Installer Finger | fast blinking | short + long beep |
BACKLIGHT ON/OFF
Action | Finger | Backlight | Buzzer Sound |
---|---|---|---|
Swipe Installer Finger 4 times | slow blinking | short beep | |
Wait 5 seconds (until fast blinking) | short beep | ||
Swipe Installer Finger | fast blinking | short + long beep |
Installer Programming block diagram
Swipe the Installer Finger 1 to 4 times depending of the desired menu
ADMINISTRATOR PROGRAMMING BY KEYPAD
Note: Entering this menu is done by admin PIN Code. You can not enter with Admin Finger
Note: The Fingerprint can be deleted by keypad, only if it is enrolled with keypad.
Example 1: Add user finger to Relay1 – Press 1234 + A + 1 + 1 + 1 + 01 +
A + Enroll finger 6 times. 0A to exit.
Example 2: Add user PIN 147 to Relay2 – Press 1234 + A + 1 + 2 + 2 + 02 +
A + 147 + A. 0A to exit.
INSTALLER PROGRAMMING BY KEYPAD
Note: Entering this menu is done by installer PIN Code. You can not enter with Installer Finger.
Example: Change relay1 time to 2 seconds – 5678 + A + 1 + 02 + A.
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.