charder HM202P Portable Height Stadiometer
Explanation of Text/Symbols on Device Label/Packaging
Copyright Notice
Charder Electronic Co., Ltd.No.103, Guozhong Rd., Dali Dist., Taichung City
41262 TaiwanTel: +886-4-2406 3766 Fax: +886-4-2406 5612Website:
www.chardermedical.com E-mail:
info_cec@charder.com.tw.Copyright© Charder
Electronic Co., Ltd. All rights reserved. This user manual is protected by
international copyright law. All content is licensed, and usage is subject to
written authorization from Charter Electronic Co., Ltd. (hereinafter Charter)
Charter is not liable for any damage caused by a failure to adhere to the
requirements stated in this manual. Charder reserves the right to correct
misprints in the manual without prior notice and modify the exterior of the
device for quality purposes without customer consent.
Charder Electronic Co., Ltd. No. 103, Guozhong Rd., Dali Dist., Taichung City, 41262 Taiwan.
Safety Notes
General Information
Thank you for choosing this Charder Medical device. It is designed to be easy and straightforward to operate, but if you encounter any problems not addressed in this manual, please contact your local Charder service partner. Before beginning operation of the device, please read this user manual carefully, and keep it in a safe place for reference. It contains important instructions regarding installation, proper usage, and maintenance.
Intended Purpose
- This medical device is designed to be used in accordance with national regulations, to measure height within specifications, for height-related usage by professionals.
Clinical Benefit
- Measurement results can be used by professionals to diagnose (and monitor) height-related issues.
General Handling
- The device should be placed on a stable, flat, solid, non-slippery surface.
- Ensure all parts are properly locked and tightened before operating the device.
Safety Instructions
- The device has an expected service life of 5 years when correctly handled, serviced, and periodically inspected in accordance with the manufacturer’s instructions.
Cleaning
- The device surface should be cleaned using alcohol-based wipes.
- Corrosive cleaning liquids should not be used.
Warranty/Liability
- The period of warranty shall be eighteen (18) months, beginning on the date of purchase. Please retain your receipt as proof of purchase.
- No responsibility shall be accepted for damage caused through any of the following reasons: unsuitable or improper storage or use, incorrect installation or commissioning by the owner or third parties, natural wear, and tear, changes or modifications, or incorrect or negligent handling.
Incident Reporting
- Any serious incident that has occurred in relation to the device should be reported to the manufacturer, EU representative (if the device is used in an EU member state), and the competent authority of the user/subject’s member state.
Installation
Parts
No. | Item | Quantity |
---|---|---|
1. | Wall stabilizer | 1 |
2. | Head Stopper | 1 |
3. | Base Platform | 1 |
4. | Height rod | 4 |
5. | Measuring tape kit | 1 |
6. | MS6111 standard slider (red) OR | 1 |
7 | MS6110 slider (white) | 1 |
8 | User Manual | 1 |
- Wall stabilizer
- Head stopper
- Base Platform
- Height Rod
- Measuring tape kit
- slider (red)
- slider (white)
Assembly
- Insert wall stabilizer into measuring tape kit.
- Pull down the measuring tape, and attach the measuring tape kit with a height rod.
- Attach head stopper to measuring tape kit and rod.
- Assemble height rods, measuring tape kit, and platform together.
- Hitch measuring tape to hook at the slider to complete assembly.
- With scale: upper hook
- Without scale: lower hook
Packing
- Carefully re-pack HM202P in the box as seen in the image above, to avoid damaging the device.
Using Device
Height measurement only
- If a compatible Charder floor scale (MS6110 or MS6111) is not used together with the HM202P, the measuring tape should be connected to the lower hook.
Height and weight measurement (with MS6110 or MS6111)
-
The measuring tape should be connected to the upper hook.
-
If HM202P is used with MS6110 (adjustable feet), the white slider should be used.
-
If HM202P is used with MS6111 (without adjustable feet), the red slider should be used.
Conducting measurement
- Place the wall stabilizer against the wall.
- Ensure that the subject is standing up straight. Slide the head stopper down until it touches the top of the subject’s head.
View height measurement in window
Product Specifications
Model | HM202P |
---|
Height Measurement
| Range| 20-205 cm
8-81 in
Graduation| 1 mm 1/16 in
Accuracy| ±10 mm
Dimensions
| Overall| 406(W) x 585(D) x 2200(H) mm
Base| 406(W) x 365(D) mm
Device Weight (approximate)| 3.8 kg / 8.4 lb (Carry case 1.1 kg / 2.4
lb)
Operation Temperature & Humidity| 5℃~35℃
Declaration of Conformity
- The manufacturer hereby declares that this product is in conformity with the regulations and standards outlined in the following directives:
CE
- 93/42/EEC as amended by 2007/47/EC Medical Device Directive Classification: Class I with measuring function
- RoHS Directive 2011/65/EU and Delegated Directive (EU) 2015/863
Authorized EU Representative
Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City, 41262 Taiwan (R.O.C.) CD-IN-1365 15247G 2022/06.
Charder Electronic Co., Ltd.
- No.103, Guozhong Rd., Dali Dist., Taichung City 41262 Taiwan
- Tel: +886-4-2406 3766 Fax: +886-4-2406 5612
- Website: www.chardermedical.com. E-mail: info_cec@charder.com.tw.