Turbo H0690 Bathroom Heater Instruction Manual
- June 12, 2024
- TURBO
Table of Contents
Assembly instructions
(please retain and file together with the purchase receipt)
Product overview special colors
Radiator dimensions
Problem | Reason | Trouble-shooting | Remedy |
---|---|---|---|
The radiator is luke warm | circulation blocked | Air in the radiator | |
Connection issue (reverse in/out flow) Radiator needs bleeding | Bleed the |
radiator
Check the non return valve is connected properly Perform a hydraulic balancing
The radiator makes unusual noises| circulation blocked
system pressure incorrect – adjust accordingly| Air in the radiator Valve not
regulating Faulty valves| Bleed the radiator
Check the valves and thermostatic control Perform a hydraulic balancing
The radiator “pulses” in the heating and cooling mode.| Expansion noises when
using a heating rod or particles are circulating in the system.| | Here, there
is no risk and no action required.
The radiator has visual i m pa i rements/defects| | | Please contact the
retailer of the product.
The radiator should be equipped with a thermostatic control or heating rod.| |
| Contact the manufacturer of the thermostatic control or heating rod.
0626
17
TURBO
EN 442-1 valid version
LE/SH-Nr.02/2019-01
Heating systems in buildings
Reaction to fire: A1
Release of dangerous substance: none
Pressure tightness: no leakage at 1,3 x MOP
Resistance to pressure:
– no breakage at 1,69 x MOP
– Maximum operating pressure (MOP) 10 bar
Surface temperature: Maximum 95°C;
Rated thermal output:
307 – 886 W
Durability as:
Resistance against corrosion: no corrosion after
100 h humidity
Resistance against minor impact: Class 0