TDX 730355 Inline and Exhaust Kit Instruction Manual

June 4, 2024
TDX

TDX 730355 Inline and Exhaust Kit

INSTALLATION INSTRUCTIONS

  1. Turn off the mains power supply.

  2. Unpack the fixture carefully and place it on a flat surface.

  3. Remove the vent grille by unclipping and pulling away from the vent.

  4. Consider the position that you wish the exhaust fan to be installed in carefully. Take care to avoid structural elements and existing wiring when selecting the position for your exhaust fan.

  5. Mark and cut out a 155mm diameter hole into the ceiling for the entry point and exit point.

  6. Cut the hole in the ceiling using a suitable plaster saw, jig saw or hole saw. Always wear protective clothing, safety glasses and an appropriate respirator mask when cutting into plaster. Double check there are no
    hidden electrical cables or ceiling battens before cutting.

  7. Consider the optimal position for the exhaust fan, ideally centered between both vents.

  8. Ensure that the exhaust fan is located within 3m of each vent so that the 1 x 3m ducting can be fitted.
    If required cut ducting shorter.

  9. Remove the main body (Fig.1) by unclipping the plastic clasps (loosen locking screws first) and lifting the main body out of the housing base.

  10. Secure the housing base to a suitable mounting point using the mounting holes in the base (Fig.2) and refit the main body (Fig.3) ensuring the direction of airflow is facing as per desired operation. Ensure clasps are attached firmly and locking screws tightened.TDX 730355 Inline and Exhaust Kit fig 1

  11. Insert the two pin power cable into an existing power point socket in the ceiling cavity as previously installed by a licensed electrical contractor.
    NOTE: If installation of power sockets is required, it must be carried out by a Licences Electrical Contractor in accordance to ASINZS 3000.

  12. Unfold the two 3m ducts and attach to both vents and ends of the exhaust fan using the supplied duct clamps.

  13. Try to avoid sharp 90 degree angles in the ducting as this will severely decrease airflow. Also ensure ducting is smoothly laid out and stretched out firmly.

  14. Attach both vents to the ceiling using suitable screws for the surface material.

  15. Replace the grille by pressing against the vent until it snaps into place.

  16. Turn on the power at the mains.

  17. Switch unit on at the wall switch.

  18. When cleaning grille, switch off all power, remove grille and wipe with damp cloth. Allow grille to dry before re-fitting.

WARNING

  • Read all instructions thoroughly prior to installation.
  • This product is intended for DIY installations where suitable switched power outlets are already installed. All new installations or modifications to fixed wiring must be conducted by a Licenced Electrical Contractor.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Young children should be supervised to ensure that they do not play with this appliance.
  • This product is intended for domestic use and should not be subject to environments producing sawdust or similar airborne hazards.
  • Do not cut or remove ceiling beams to install this device.
  • Not designed for outdoor use.
  • Do not install the inline exhaust fan in high-temperature areas such as above or adjacent to cooking equipment.
  • Do not cover Inline fan with Insulation. A minimum of 120mm clearance must be maintained between fan and insulation.
  • Failure to follow these instructions will result in breakages and will invalidate warranty.
  • If the product is functioning irregularly, please turn the power off and contact the nearest authorized dealer.
  • Do not perform modifications or change parts within the product.
  • Care must be taken in order to avoid any water ingress on the inline exhaust fan from the duct.
  • Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances
  • Ensure there is sufficient airflow into the room with the inlet duct installed so that air flow is encouraged.
  • Although this product is IPX4 rated, ensure no water or condensation flows into the fan motor.
  • Switch the unit off when cleaning.

SPECIFICATIONS

  • Fitting
    • Plastic body and vents
  • Construction Fan
    • Class II
  • IP Rating:
    • IPX4
  • Voltage
    • 240V, 50Hz
  • Wattage
    • 47W
  • Airflow
    • 500m3 /hr
  • Noise
    • <63dB
  • Ta
    • Maximum 40° C
  • Weight
    • 2.2Kg (Exhaust Fan only)

When selecting a mounting location, please consider the following:

  1. The exhaust Fan motor must be installed into a horizontal location.
  2. Prior to vent installation, inspect the ceiling cavity to check for hidden beams, structures, and concealed electrical cabling. The wall switch should not be installed where it can be touched by someone within a bath or shower.
  3. Position fan in as central a location as possible, to maximize ventilation to all areas.
  4. Regulations concerning the discharge of air must be fulfilled.
  5. Do not install the exhaust fan within 1 m distance from a ceiling or wall-mounted heat source.
  6. Ensure there is at least 250mm clearance around and above the exhaust fan once it is installed in the ceiling cavity. The exhaust fan must be securely fixed to reduce noise and vibration.TDX 730355 Inline and Exhaust Kit fig 3

WARRANTY

  • TDX warrants this product against defects in manufacture and workmanship for a period of 3 years from the date of purchase. For products used in non-domestic or commercial applications, TDX warrants this product for a period of 3 months from the date of purchase. This warranty is only valid for products installed by a qualified electrical contractor and operated within the guidelines specified by TDX, and within the correct operating voltage ranges as stated on the product’s rating label.
  • Warranty does not include damage or loss arising from incorrect installation, operation or maintenance of this product, damage caused through modification, incorrect installation, service by unqualified or unauthorized personnel or lack of regular maintenance and cleaning. Proof of installation by qualified personnel may be required, eg. Electrical Safety Certificate. Proof of purchase must be supplied with all warranty claims.
  • This warranty is provided in addition to any other rights and remedies of the customer under any law.
  • In applications not intended for household, personal or domestic use, liability is limited to replacement or reimbursement of the product only. TDX does not warranty the costs of removal or re-installation of this product or associated components.
  • Our goods come with guarantees that cannot be excluded under the New Zealand Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure.