AMANA AM9C96 Two-Stage Gas Furnace User Guide
- June 4, 2024
- Amana
Table of Contents
AMANA AM9C96 Two-Stage Gas Furnace
Standard Features | Cabinet Features |
---|
• Energy-efficient multi-speed ECM blower motor
• Heavy-duty stainless-steel tubular heat exchanger
• Stainless-steel secondary heat exchanger
• Two-stage gas valve provides quiet, economical heating
• Durable Silicon Nitride igniter
• Quiet two-speed induced draft blower
• Self-diagnostic control board with constant memory
fault code history output to a LED
• Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
• Low continuous fan speed options offer quiet air circulation
• All models comply with California 40 ng/J
Low NOx emissions standard
• Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
| • Designed for multi-position installation up flow, horizontal left or right
• Certified for direct vent (2-pipe) or non-direct vent (1-pipe)
• Easy-to-install top venting with optional side venting
• Convenient left or right connection
for gas and electrical service
• Cabinet air leakage (Q Leak) ≤ 2%
• Heavy-gauge steel cabinet with durable finish
• Fully insulated heat exchanger and blower section
• Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications
| AM9C96 0303ANA| AM9C96 0403ANA| AM9C96 0603ANA| AM9C96
0603BNA| AM9C96 0803BNA| AM9C96 0804CNA| AM9C96 1004CNA|
AM9C96 1005CNA| AM9C96 1205DNA
---|---|---|---|---|---|---|---|---|---
Heating Data| | | | | | | | |
High Fire Input¹| 30,000| 40,000| 60,000| 60,000| 80,000| 80,000| 100,000|
100,000| 120,000
High Fire Output¹| 28,800| 38,400| 57,600| 57,600| 76,800| 76,800| 96,000|
96,000| 115,200
Low-Fire Input¹| 21,000| 28,000| 42,000| 42,000| 56,000| 56,000| 70,000|
70,000| 84,000
Low-Fire Output¹| 20,160| 26,880| 40,320| 40,320| 53,760| 53,760| 67,200|
67,200| 80,640
AFUE²| 96| 96| 96| 96| 96| 96| 96| 96| 96
Temp. Rise Range (°F)| 20- 50| 20- 50| 30- 60| 35- 65| 35- 65| 25- 55| 35- 65|
35- 65| 35- 65
Vent Diameter³| 2″- 3″| 2″- 3″| 2″- 3″| 2″- 3″| 2″- 3″| 2″- 3″| 2″- 3″| 2″-
3″| 2″- 3″
No. of Burners| 2| 2| 3| 3| 4| 4| 5| 5| 6
Circulator Blower| | | | | | | | |
Available AC @ 0.5″ ESP| 1.5- 2| 1.5- 3| 1.5- 3| 1.5- 3| 1.5- 3| 2.5- 4| 1.5-
4| 3- 5| 3- 5
Size (D x W)| 11″ x 6″| 11” x 6”| 11” x 6”| 11″ x 8″| 11″ x 8″| 11″ x 10″| 11″
x 10″| 11″ x 10″| 11″ x 11″
Horsepower @ 1075 RPM| 1/2| 1/2| 1/2| 1/2| 1/2| 3/4| 1| 1| 1
Speed| 9| 9| 9| 9| 9| 9| 9| 9| 9
Filter Size (in²) (Qty)
| (1) 16 x 25
(side) or (1) 14 x 25
(bottom)
| (1) 16 x 25
(side) or (1) 14 x 25
(bottom)
| (1) 16 x 25
(side) or (1) 14 x 25
(bottom)
| (1) 16 x 25
(side or bottom)
| (1) 16 x 25
(side or bottom)
| (1) 16 x 25
(side or bottom)
| (1) 16 x 25
(side or bottom)
| (1) 20 x 25
(bottom) or (2) 16 x
25 (side)
| (1) 20 x 25
(bottom) or (2) 16 x
25 (side)
Electrical Data| | | | | | | | |
Min. Circuit Ampacity⁴| 8.6| 8.6| 8.6| 8| 8| 11.6| 13.3| 13.3| 13.3
Max. Overcurrent (amps)⁵| 15| 15| 15| 15| 15| 15| 20| 20| 20
Shipping Weight (lbs)| 106| 106| 110| 115| 118| 123| 140| 140| 154
- Natural Gas BTU/h
- DOE AFUE based upon Isolated Combustion System (ICS)
- Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2″ or 3″ in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/ code requirements and must be 2″ or 3″ diameter PVC.
- Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
- Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
- All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
- Gas Service Connection ½” FPT
- Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
- For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
- For servicing or cleaning, a 24″ front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
| Air Discharge| | Air Return
---|---|---|---
Model| A| B| C| D| E
AM9C960303ANA| 14″| 12½”| 10½”| 8⅝”| 10⅛”
AM9C960403ANA| 14”| 12½”| 10½”| 8⅝”| 10⅛”
AM9C960603ANA| 14”| 12½”| 10½”| 8⅝”| 10⅛”
AM9C960603BNA| 17½”| 16″| 13⅞”| 12⅛”| 13⅝”
AM9C960803BNA| 17½”| 16”| 13⅞”| 12⅛”| 13⅝”
AM9C960804CNA| 21″| 19½”| 17⅜”| 16″| 17½”
AM9C961004CNA| 21″| 19½”| 17⅜”| 16″| 17½”
AM9C961005CNA| 21″| 19½”| 17⅜”| 16″| 17½”
AM9C961205DNA| 24½| 23″| 20⅞”| 19⅜”| 20⅞”
Minimum Clearances to Combustible Materials
Position| Sides| Rear| Front| Bottom| Flue|
Top
---|---|---|---|---|---|---
Upflow| 0″| 0″| 3″| C| 0″| 1″
Horizontal| 6″| 0″| 3″| C| 0″| 6″
LOW STAGE COOLING AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
*M9C96
0303AN
|
Y/Y1
| F01| 753| 708| 663| 616| 568| 513| 470| 423
F02| 915| 883| 845| 809| 773| 730| 690| 650
F03| 529| 518| 461| 394| 343| 288| 223| N/A
F04^| 880| 843| 807| 768| 723| 683| 643| 590
F05| 1055| 1022| 990| 959| 930| 891| 858| 825
F06| 1101| 1072| 1040| 1010| 980| 949| 918| 881
F07| 1190| 1162| 1134| 1104| 1077| 1042| 1013| 982
F08| 1183| 1157| 1130| 1103| 1077| 1047| 1018| 988
F09| 1229| 1206| 1178| 1153| 1128| 1100| 1070| 1042
*M9C96
0403AN
|
Y/Y1
| F01| 733| 691| 650| 602| 553| 498| 448| 402
F02| 1051| 1024| 996| 966| 935| 907| 868| 836
F03| 665| 620| 570| 517| 462| 407| 359| 309
F04^| 915| 881| 846| 814| 780| 737| 695| 652
F05| 1138| 1114| 1092| 1064| 1035| 1006| 977| 947
F06| 887| 855| 823| 790| 751| 705| 666| 608
F07| 1189| 1163| 1138| 1111| 1085| 1059| 1032| 1001
F08| 1266| 1243| 1218| 1197| 1172| 1148| 1123| 1099
F09| 1342| 1324| 1305| 1280| 1263| 1239| 1216| 1193
*M9C96 0603AN
|
Y/Y1
| F01| 900| 867| 830| 798| 758| 718| 682| 645
F02| 1292| 1272| 1248| 1227| 1206| 1184| 1162| 1137
F03| 688| 649| 603| 551| 499| 447| 405| 359
F04^| 866| 830| 797| 759| 717| 675| 634| 591
F05| 1223| 1195| 1176| 1149| 1124| 1101| 1074| 1047
F06| 1037| 1004| 975| 950| 921| 886| 853| 823
F07| 1079| 1053| 1025| 1000| 970| 941| 911| 873
F08| 1128| 1099| 1075| 1050| 1022| 993| 965| 937
F09| 1171| 1148| 1124| 1096| 1070| 1045| 1017| 988
*M9C96 0603BN
|
Y/Y1
| F01| 914| 864| 815| 762| 704| 654| 604| 560
F02| 1121| 1083| 1041| 996| 953| 906| 861| 818
F03| 758| 696| 636| 572| 512| 460| 412| N/A
F04^| 960| 917| 864| 812| 764| 708| 661| 614
F05| 1164| 1123| 1084| 1042| 1003| 960| 920| 871
F06| 1219| 1180| 1141| 1102| 1062| 1020| 978| 940
F07| 1273| 1240| 1207| 1171| 1128| 1089| 1051| 1012
F08| 1307| 1270| 1235| 1198| 1160| 1122| 1083| 1043
F09| 1427| 1390| 1362| 1327| 1297| 1260| 1224| 1193
*M9C96
0803BN
|
Y/Y1
| F01| 1205| 1169| 1131| 1091| 1053| 1014| 974| 934
F02| 1415| 1385| 1355| 1322| 1291| 1255| 1219| 1186
F03| 696| 635| 568| 500| 442| 390| 336| 255
F04^| 1152| 1112| 1076| 1035| 996| 954| 916| 868
F05| 1321| 1287| 1251| 1217| 1181| 1146| 1112| 1072
F06| 901| 851| 801| 746| 690| 638| 587| 543
F07| 1112| 1076| 1032| 992| 949| 905| 858| 819
F08| 1290| 1252| 1215| 1182| 1143| 1107| 1071| 1032
F09| 1471| 1440| 1409| 1377| 1347| 1314| 1283| 1247
LOW STAGE COOLING AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
*M9C96
0804CN
|
Y/Y1
| F01| 1289| 1234| 1180| 1122| 1058| 991| 917| 840
F02| 1836| 1784| 1741| 1703| 1664| 1628| 1585| 1537
F03| 1297| 1246| 1199| 1142| 1083| 1020| 949| 872
F04^| 1194| 1137| 1079| 1014| 948| 873| 792| 712
F05| 1748| 1696| 1650| 1612| 1574| 1526| 1478| 1428
F06| 1451| 1399| 1354| 1309| 1256| 1200| 1142| 1077
F07| 1587| 1534| 1489| 1445| 1406| 1354| 1298| 1244
F08| 1683| 1633| 1589| 1546| 1502| 1460| 1406| 1355
F09| 1919| 1890| 1846| 1807| 1771| 1735| 1694| 1650
*M9C96
1004CN
|
Y/Y1
| F01| 1475| 1421| 1369| 1314| 1260| 1207| 1152| 1097
F02| 1791| 1741| 1699| 1652| 1609| 1561| 1513| 1465
F03| 924| 846| 767| 684| 606| 529| 463| 398
F04^| 1259| 1197| 1138| 1074| 1015| 947| 885| 821
F05| 1710| 1660| 1613| 1583| 1517| 1470| 1421| 1374
F06| 1592| 1536| 1486| 1436| 1383| 1331| 1281| 1233
F07| 1627| 1574| 1524| 1474| 1423| 1370| 1320| 1271
F08| 1921| 1879| 1840| 1791| 1751| 1705| 1656| 1610
F09| 2026| 1981| 1929| 1901| 1858| 1819| 1773| 1733
*M9C96
1005CN
|
Y/Y1
| F01| 1259| 1197| 1138| 1074| 1015| 947| 885| 821
F02| 1791| 1741| 1699| 1652| 1609| 1561| 1513| 1465
F03| 1176| 1108| 1044| 980| 913| 845| 779| 718
F04^| 1347| 1286| 1231| 1172| 1115| 1055| 995| 933
F05| 1921| 1879| 1840| 1791| 1751| 1705| 1656| 1610
F06| 1446| 1404| 1335| 1280| 1226| 1171| 1117| 1062
F07| 1618| 1567| 1510| 1460| 1413| 1364| 1312| 1262
F08| 2009| 1964| 1918| 1886| 1852| 1811| 1759| 1722
F09| 2161| 2122| 2084| 2048| 2010| 1973| 1940| 1914
*M9C96 1205DN
|
Y/Y1
| F01| 1766| 1712| 1666| 1612| 1558| 1506| 1450| 1395
F02| 2205| 2157| 2110| 2064| 2021| 1974| 1925| 1879
F03| 1118| 1035| 952| 860| 750| 663| 590| 519
F04^| 1684| 1620| 1561| 1499| 1438| 1378| 1318| 1259
F05| 2031| 1981| 1933| 1901| 1850| 1799| 1750| 1702
F06| 1220| 1145| 1070| 995| 952| 907| 811| 725
F07| 1357| 1311| 1243| 1175| 1107| 1021| 932| 861
F08| 1906| 1877| 1828| 1778| 1726| 1674| 1622| 1568
F09| 2454| 2396| 2347| 2296| 2250| 2202| 2157| 2113
Notes
- DEFAULT SPEED
- All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
- For most jobs, about 400 CFM per ton when cooling is desirable.
- INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
HIGH STAGE COOLING AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
*M9C96
0303AN
|
Y2
| F01| 753| 708| 663| 616| 568| 513| 470| 423
F02| 915| 883| 845| 809| 773| 730| 690| 650
F03| 529| 518| 461| 394| 343| 288| 223| N/A
F04| 880| 843| 807| 768| 723| 683| 643| 590
F05^| 1055| 1022| 990| 959| 930| 891| 858| 825
F06| 1101| 1072| 1040| 1010| 980| 949| 918| 881
F07| 1190| 1162| 1134| 1104| 1077| 1042| 1013| 982
F08| 1183| 1157| 1130| 1103| 1077| 1047| 1018| 988
F09| 1229| 1206| 1178| 1153| 1128| 1100| 1070| 1042
*M9C96
0403AN
|
Y2
| F01| 733| 691| 650| 602| 553| 498| 448| 402
F02| 1051| 1024| 996| 966| 935| 907| 868| 836
F03| 665| 620| 570| 517| 462| 407| 359| 309
F04| 915| 881| 846| 814| 780| 737| 695| 652
F05^| 1138| 1114| 1092| 1064| 1035| 1006| 977| 947
F06| 887| 855| 823| 790| 751| 705| 666| 608
F07| 1189| 1163| 1138| 1111| 1085| 1059| 1032| 1001
F08| 1266| 1243| 1218| 1197| 1172| 1148| 1123| 1099
F09| 1342| 1324| 1305| 1280| 1263| 1239| 1216| 1193
*M9C96 0603AN
|
Y2
| F01| 900| 867| 830| 798| 758| 718| 682| 645
F02| 1292| 1272| 1248| 1227| 1206| 1184| 1162| 1137
F03| 688| 649| 603| 551| 499| 447| 405| 359
F04| 866| 830| 797| 759| 717| 675| 634| 591
F05^| 1223| 1195| 1176| 1149| 1124| 1101| 1074| 1047
F06| 1037| 1004| 975| 950| 921| 886| 853| 823
F07| 1079| 1053| 1025| 1000| 970| 941| 911| 873
F08| 1128| 1099| 1075| 1050| 1022| 993| 965| 937
F09| 1171| 1148| 1124| 1096| 1070| 1045| 1017| 988
*M9C96 0603BN
|
Y2
| F01| 914| 864| 815| 762| 704| 654| 604| 560
F02| 1121| 1083| 1041| 996| 953| 906| 861| 818
F03| 758| 696| 636| 572| 512| 460| 412| N/A
F04| 960| 917| 864| 812| 764| 708| 661| 614
F05^| 1164| 1123| 1084| 1042| 1003| 960| 920| 871
F06| 1219| 1180| 1141| 1102| 1062| 1020| 978| 940
F07| 1273| 1240| 1207| 1171| 1128| 1089| 1051| 1012
F08| 1307| 1270| 1235| 1198| 1160| 1122| 1083| 1043
F09| 1427| 1390| 1362| 1327| 1297| 1260| 1224| 1193
*M9C96
0803BN
|
Y2
| F01| 1205| 1169| 1131| 1091| 1053| 1014| 974| 934
F02| 1415| 1385| 1355| 1322| 1291| 1255| 1219| 1186
F03| 696| 635| 568| 500| 442| 390| 336| 255
F04| 1152| 1112| 1076| 1035| 996| 954| 916| 868
F05^| 1321| 1287| 1251| 1217| 1181| 1146| 1112| 1072
F06| 901| 851| 801| 746| 690| 638| 587| 543
F07| 1112| 1076| 1032| 992| 949| 905| 858| 819
F08| 1290| 1252| 1215| 1182| 1143| 1107| 1071| 1032
F09| 1471| 1440| 1409| 1377| 1347| 1314| 1283| 1247
HIGH STAGE COOLING AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
*M9C96
0804CN
|
Y2
| F01| 1289| 1234| 1180| 1122| 1058| 991| 917| 840
F02| 1836| 1784| 1741| 1703| 1664| 1628| 1585| 1537
F03| 1297| 1246| 1199| 1142| 1083| 1020| 949| 872
F04| 1194| 1137| 1079| 1014| 948| 873| 792| 712
F05^| 1748| 1696| 1650| 1612| 1574| 1526| 1478| 1428
F06| 1451| 1399| 1354| 1309| 1256| 1200| 1142| 1077
F07| 1587| 1534| 1489| 1445| 1406| 1354| 1298| 1244
F08| 1683| 1633| 1589| 1546| 1502| 1460| 1406| 1355
F09| 1919| 1890| 1846| 1807| 1771| 1735| 1694| 1650
*M9C96
1004CN
|
Y2
| F01| 1475| 1421| 1369| 1314| 1260| 1207| 1152| 1097
F02| 1791| 1741| 1699| 1652| 1609| 1561| 1513| 1465
F03| 924| 846| 767| 684| 606| 529| 463| 398
F04| 1259| 1197| 1138| 1074| 1015| 947| 885| 821
F05^| 1710| 1660| 1613| 1583| 1517| 1470| 1421| 1374
F06| 1592| 1536| 1486| 1436| 1383| 1331| 1281| 1233
F07| 1627| 1574| 1524| 1474| 1423| 1370| 1320| 1271
F08| 1921| 1879| 1840| 1791| 1751| 1705| 1656| 1610
F09| 2026| 1981| 1929| 1901| 1858| 1819| 1773| 1733
*M9C96
1005CN
|
Y2
| F01| 1259| 1197| 1138| 1074| 1015| 947| 885| 821
F02| 1791| 1741| 1699| 1652| 1609| 1561| 1513| 1465
F03| 1176| 1108| 1044| 980| 913| 845| 779| 718
F04| 1347| 1286| 1231| 1172| 1115| 1055| 995| 933
F05^| 1921| 1879| 1840| 1791| 1751| 1705| 1656| 1610
F06| 1446| 1404| 1335| 1280| 1226| 1171| 1117| 1062
F07| 1618| 1567| 1510| 1460| 1413| 1364| 1312| 1262
F08| 2009| 1964| 1918| 1886| 1852| 1811| 1759| 1722
F09| 2161| 2122| 2084| 2048| 2010| 1973| 1940| 1914
*M9C96 1205DN
|
Y2
| F01| 1766| 1712| 1666| 1612| 1558| 1506| 1450| 1395
F02| 2205| 2157| 2110| 2064| 2021| 1974| 1925| 1879
F03| 1118| 1035| 952| 860| 750| 663| 590| 519
F04| 1684| 1620| 1561| 1499| 1438| 1378| 1318| 1259
F05^| 2031| 1981| 1933| 1901| 1850| 1799| 1750| 1702
F06| 1220| 1145| 1070| 995| 952| 907| 811| 725
F07| 1357| 1311| 1243| 1175| 1107| 1021| 932| 861
F08| 1906| 1877| 1828| 1778| 1726| 1674| 1622| 1568
F09| 2454| 2396| 2347| 2296| 2250| 2202| 2157| 2113
Notes
- DEFAULT SPEED
- All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
- For most jobs, about 400 CFM per ton when cooling is desirable.
- INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
CIRCULATION AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
*M9C96
0303AN
|
G
| F01| 753| 708| 663| 616| 568| 513| 470| 423
F02| 915| 883| 845| 809| 773| 730| 690| 650
F03| 529| 518| 461| 394| 343| 288| 223| N/A
F04| 880| 843| 807| 768| 723| 683| 643| 590
F05| 1055| 1022| 990| 959| 930| 891| 858| 825
F06| 1101| 1072| 1040| 1010| 980| 949| 918| 881
F07| 1190| 1162| 1134| 1104| 1077| 1042| 1013| 982
F08| 1183| 1157| 1130| 1103| 1077| 1047| 1018| 988
F09| 1229| 1206| 1178| 1153| 1128| 1100| 1070| 1042
*M9C96
0403AN
|
G
| F01| 733| 691| 650| 602| 553| 498| 448| 402
F02| 1051| 1024| 996| 966| 935| 907| 868| 836
F03| 665| 620| 570| 517| 462| 407| 359| 309
F04| 915| 881| 846| 814| 780| 737| 695| 652
F05| 1138| 1114| 1092| 1064| 1035| 1006| 977| 947
F06| 887| 855| 823| 790| 751| 705| 666| 608
F07| 1189| 1163| 1138| 1111| 1085| 1059| 1032| 1001
F08| 1266| 1243| 1218| 1197| 1172| 1148| 1123| 1099
F09| 1342| 1324| 1305| 1280| 1263| 1239| 1216| 1193
*M9C96 0603AN
|
G
| F01| 900| 867| 830| 798| 758| 718| 682| 645
F02| 1292| 1272| 1248| 1227| 1206| 1184| 1162| 1137
F03| 688| 649| 603| 551| 499| 447| 405| 359
F04| 866| 830| 797| 759| 717| 675| 634| 591
F05| 1223| 1195| 1176| 1149| 1124| 1101| 1074| 1047
F06| 1037| 1004| 975| 950| 921| 886| 853| 823
F07| 1079| 1053| 1025| 1000| 970| 941| 911| 873
F08| 1128| 1099| 1075| 1050| 1022| 993| 965| 937
F09| 1171| 1148| 1124| 1096| 1070| 1045| 1017| 988
*M9C96 0603BN
|
G
| F01| 914| 864| 815| 762| 704| 654| 604| 560
F02| 1121| 1083| 1041| 996| 953| 906| 861| 818
F03| 758| 696| 636| 572| 512| 460| 412| N/A
F04| 960| 917| 864| 812| 764| 708| 661| 614
F05| 1164| 1123| 1084| 1042| 1003| 960| 920| 871
F06| 1219| 1180| 1141| 1102| 1062| 1020| 978| 940
F07| 1273| 1240| 1207| 1171| 1128| 1089| 1051| 1012
F08| 1307| 1270| 1235| 1198| 1160| 1122| 1083| 1043
F09| 1427| 1390| 1362| 1327| 1297| 1260| 1224| 1193
*M9C96
0803BN
|
G
| F01| 1205| 1169| 1131| 1091| 1053| 1014| 974| 934
F02| 1415| 1385| 1355| 1322| 1291| 1255| 1219| 1186
F03| 696| 635| 568| 500| 442| 390| 336| 255
F04| 1152| 1112| 1076| 1035| 996| 954| 916| 868
F05| 1321| 1287| 1251| 1217| 1181| 1146| 1112| 1072
F06| 901| 851| 801| 746| 690| 638| 587| 543
F07| 1112| 1076| 1032| 992| 949| 905| 858| 819
F08| 1290| 1252| 1215| 1182| 1143| 1107| 1071| 1032
F09| 1471| 1440| 1409| 1377| 1347| 1314| 1283| 1247
CIRCULATION AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| CFM| CFM| CFM| CFM| CFM| CFM| CFM
*M9C96
0804CN
|
G
| F01| 1289| 1234| 1180| 1122| 1058| 991| 917| 840
F02| 1836| 1784| 1741| 1703| 1664| 1628| 1585| 1537
F03| 1297| 1246| 1199| 1142| 1083| 1020| 949| 872
F04| 1194| 1137| 1079| 1014| 948| 873| 792| 712
F05| 1748| 1696| 1650| 1612| 1574| 1526| 1478| 1428
F06| 1451| 1399| 1354| 1309| 1256| 1200| 1142| 1077
F07| 1587| 1534| 1489| 1445| 1406| 1354| 1298| 1244
F08| 1683| 1633| 1589| 1546| 1502| 1460| 1406| 1355
F09| 1919| 1890| 1846| 1807| 1771| 1735| 1694| 1650
*M9C96
1004CN
|
G
| F01| 1475| 1421| 1369| 1314| 1260| 1207| 1152| 1097
F02| 1791| 1741| 1699| 1652| 1609| 1561| 1513| 1465
F03| 924| 846| 767| 684| 606| 529| 463| 398
F04| 1259| 1197| 1138| 1074| 1015| 947| 885| 821
F05| 1710| 1660| 1613| 1583| 1517| 1470| 1421| 1374
F06| 1592| 1536| 1486| 1436| 1383| 1331| 1281| 1233
F07| 1627| 1574| 1524| 1474| 1423| 1370| 1320| 1271
F08| 1921| 1879| 1840| 1791| 1751| 1705| 1656| 1610
F09| 2026| 1981| 1929| 1901| 1858| 1819| 1773| 1733
*M9C96
1005CN
|
G
| F01| 1259| 1197| 1138| 1074| 1015| 947| 885| 821
F02| 1791| 1741| 1699| 1652| 1609| 1561| 1513| 1465
F03| 1176| 1108| 1044| 980| 913| 845| 779| 718
F04| 1347| 1286| 1231| 1172| 1115| 1055| 995| 933
F05| 1921| 1879| 1840| 1791| 1751| 1705| 1656| 1610
F06| 1446| 1404| 1335| 1280| 1226| 1171| 1117| 1062
F07| 1618| 1567| 1510| 1460| 1413| 1364| 1312| 1262
F08| 2009| 1964| 1918| 1886| 1852| 1811| 1759| 1722
F09| 2161| 2122| 2084| 2048| 2010| 1973| 1940| 1914
*M9C96 1205DN
|
G
| F01| 1766| 1712| 1666| 1612| 1558| 1506| 1450| 1395
F02| 2205| 2157| 2110| 2064| 2021| 1974| 1925| 1879
F03| 1118| 1035| 952| 860| 750| 663| 590| 519
F04| 1684| 1620| 1561| 1499| 1438| 1378| 1318| 1259
F05| 2031| 1981| 1933| 1901| 1850| 1799| 1750| 1702
F06| 1220| 1145| 1070| 995| 952| 907| 811| 725
F07| 1357| 1311| 1243| 1175| 1107| 1021| 932| 861
F08| 1906| 1877| 1828| 1778| 1726| 1674| 1622| 1568
F09| 2454| 2396| 2347| 2296| 2250| 2202| 2157| 2113
Notes
- DEFAULT SPEED
- All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
- For most jobs, about 400 CFM per ton when cooling is desirable.
- INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
HEATING AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| RISE| CFM| RISE| CFM| RISE| CFM|
RISE| CFM| RISE| CFM| CFM| CFM
*M9C96
0303AN
|
W/W1
| F01^| 753| 25| 708| 26| 663| 28| 616| 30| 568| 33| 513| 470| 423
F03^^| 529| N/A| 518| N/A| 461| N/A| 394| N/A| 343| N/A| 288| 223| N/A
F04| 880| 21| 843| 22| 807| 23| 768| 24| 723| 26| 683| 643| 590
W2
| F02^| 915| 29| 883| 30| 845| 32| 809| 33| 773| 34| 730| 690| 650
F04| 880| 30| 843| 32| 807| 33| 768| 35| 723| 37| 683| 643| 590
F05| 1055| 25| 1022| 26| 990| 27| 959| 28| 930| 29| 891| 858| 825
*M9C96
0403AN
|
W/W1
| F01^| 733| 34| 691| 36| 650| 38| 602| 41| 553| 45| 498| 448| 402
F03^^| 665| N/A| 620| N/A| 570| N/A| 517| N/A| 462| N/A| 407| 359| 309
F04| 915| 27| 881| 28| 846| 29| 814| 31| 780| 32| 737| 695| 652
W2
| F02^| 1051| 34| 1024| 35| 996| 36| 966| 37| 935| 38| 907| 868| 836
F04| 915| 39| 881| 40| 846| 42| 814| 44| 780| 46| 737| 695| 652
F05| 1138| 31| 1114| 32| 1092| 33| 1064| 33| 1035| 34| 1006| 977| 947
*M9C96 0603AN
|
W/W1
| F01^| 900| 40| 867| 42| 830| 44| 798| 46| 758| 48| 718| 682| 645
F03^^| 688| N/A| 649| N/A| 603| N/A| 551| N/A| 499| N/A| 447| 405| 359
F04| 866| 42| 830| 44| 797| 46| 759| 48| 717| 50| 675| 634| 591
W2
| F02^| 1292| 41| 1272| 42| 1248| 43| 1227| 43| 1206| 44| 1184| 1162| 1137
F04^^| 866| N/A| 830| N/A| 797| N/A| 759| N/A| 717| N/A| 675| 634| 591
F05| 1223| 44| 1195| 45| 1176| 45| 1149| 46| 1124| 47| 1101| 1074| 1047
*M9C96 0603BN
|
W/W1
| F01^| 914| 41| 864| 43| 815| 46| 762| 49| 704| 53| 654| 604| 560
F03^^| 758| N/A| 696| N/A| 636| N/A| 572| N/A| 512| N/A| 460| 412| N/A
F04| 960| 39| 917| 41| 864| 43| 812| 46| 764| 49| 708| 661| 614
W2
| F02^| 1121| 48| 1083| 49| 1041| 51| 996| 54| 953| 56| 906| 861| 818
F04^^| 960| N/A| 917| N/A| 864| N/A| 812| N/A| 764| N/A| 708| 661| 614
F05| 1164| 46| 1123| 47| 1084| 49| 1042| 51| 1003| 53| 960| 920| 871
*M9C96
0803BN
|
W/W1
| F01^| 1205| 41| 1169| 43| 1131| 44| 1091| 46| 1053| 47| 1014| 974| 934
F03^^| 696| N/A| 635| N/A| 568| N/A| 500| N/A| 442| N/A| 390| 336| 255
F04| 1152| 43| 1112| 45| 1076| 46| 1035| 48| 996| 50| 954| 916| 868
W2
| F02^| 1415| 50| 1385| 51| 1355| 52| 1322| 54| 1291| 55| 1255| 1219| 1186
F04^^| 1152| N/A| 1112| N/A| 1076| N/A| 1035| N/A| 996| N/A| 954| 916| 868
F05| 1321| 54| 1287| 55| 1251| 57| 1217| 58| 1181| 60| 1146| 1112| 1072
*M9C96
0804CN
|
W/W1
| F01^| 1289| 39| 1234| 40| 1180| 42| 1122| 44| 1058| 47| 991| 917| 840
F03| 1297| 38| 1246| 40| 1199| 42| 1142| 44| 1083| 46| 1020| 949| 872
F04| 1194| 42| 1137| 44| 1079| 46| 1014| 49| 948| 52| 873| 792| 712
W2
| F02^| 1836| 39| 1784| 40| 1741| 41| 1703| 42| 1664| 43| 1628| 1585| 1537
F04^^| 1194| N/A| 1137| N/A| 1079| N/A| 1014| N/A| 948| N/A| 873| 792| 712
F05| 1748| 41| 1696| 42| 1650| 43| 1612| 44| 1574| 45| 1526| 1478| 1428
TEMP RANGE LOW
20-50
20- 50
20- 50
25-55
35-65
25- 55
TEMP RANGE HIGH
20-50
20- 50
30-60
35-65
35-65
25- 55
HEATING AIFLOW
MODEL
| THER- MOSTAT CALL|
TAP #
| EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| RISE| CFM| RISE| CFM| RISE| CFM|
RISE| CFM| RISE| CFM| CFM| CFM
*M9C96
1004CN
|
W/W1
| F01^| 1475| 42| 1421| 44| 1369| 45| 1314| 47| 1260| 49| 1207| 1152| 1097
F03^^| 924| N/A| 846| N/A| 767| N/A| 684| N/A| 606| N/A| 529| 463| 398
F04| 1259| 49| 1197| 52| 1138| 55| 1074| 58| 1015| 61| 947| 885| 821
W2
| F02^| 1791| 50| 1741| 51| 1699| 52| 1652| 54| 1609| 55| 1561| 1513| 1465
F04^^| 1259| N/A| 1197| N/A| 1138| N/A| 1074| N/A| 1015| N/A| 947| 885| 821
F05| 1710| 52| 1660| 54| 1613| 55| 1583| 56| 1517| 59| 1470| 1421| 1374
*M9C96
1005CN
|
W/W1
| F01^| 1259| 49| 1197| 52| 1138| 55| 1074| 58| 1015| 61| 947| 885| 821
F03^^| 1176| N/A| 1108| N/A| 1044| N/A| 980| N/A| 913| N/A| 845| 779| 718
F04| 1347| 46| 1286| 48| 1231| 51| 1172| 53| 1115| 56| 1055| 995| 933
W2
| F02^| 1791| 50| 1741| 51| 1699| 52| 1652| 54| 1609| 55| 1561| 1513| 1465
F04^^| 1347| N/A| 1286| N/A| 1231| N/A| 1172| N/A| 1115| N/A| 1055| 995| 933
F05| 1921| 46| 1879| 47| 1840| 48| 1791| 50| 1751| 51| 1705| 1656| 1610
*M9C96 1205DN
|
W/W1
| F01^| 1766| 42| 1712| 44| 1666| 45| 1612| 46| 1558| 48| 1506| 1450| 1395
F03^^| 1118| N/A| 1035| N/A| 952| N/A| 860| N/A| 750| N/A| 663| 590| 519
F04| 1684| 44| 1620| 46| 1561| 48| 1499| 50| 1438| 52| 1378| 1318| 1259
W2
| F02^| 2205| 48| 2157| 49| 2110| 51| 2064| 52| 2021| 53| 1974| 1925| 1879
F04^^| 1684| N/A| 1620| N/A| 1561| N/A| 1499| N/A| 1438| N/A| 1378| 1318| 1259
F05| 2031| 53| 1981| 54| 1933| 55| 1901| 56| 1850| 58| 1799| 1750| 1702
TEMP RANGE LOW
35-65
35-65
35-65
TEMP RANGE HIGH
35-65
35-65
35-65
Notes
- DEFAULT SPEED
- All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
- For most jobs, about 400 CFM per ton when cooling is desirable.
- INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
NOTES:
- SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
- MANUFACTURER’S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
- IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105v C. USE COPPER CONDUCTORS ONLY.
- UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
- TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY NO THERMOSTAT INPUTS)
COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK
- EQUIPMENT GND
- FIELD GND
- FIELD SPLICE
- SWITCH (TEMP.)
- IGNITER
- SWITCH (PRESS.)
- OVERCURRENT
- PROT. DEVICE
- JUNCTION
- TERMINAL
- INTERNAL TO
- INTEGRATED CONTROL
- PLUG CONNECTION
- LOW VOLTAGE (24V)
- LOW VOLTAGE FIELD
- HI VOLTAGE (115V)
- HI VOLTAGE FIELD
__
Model
| __
Description
| AM9C96 0303ANA| AM9C96 0403ANA| AM9C96 0603ANA| AM9C96
0603BNA| AM9C96 0803BNA
---|---|---|---|---|---|---
72950| Concentric Vent Kit (2″)| √| √| √| √| √
72951| Concentric Vent Kit (3″)| √| √| √| √| √
RF000142| Drain Kit-Horizontal Left Vertical Flue| √| √| √| √| √
EFR02| External Filter Rack with 16″x25″
Permanent Filter
| √| √| √| √| √
0170K00000S| Flush Mount Vent Kit- 3″ or 2″| √| √| √| √| √
0170K00001S| Flush Mount Vent Kit- 2″| √| √| √| √| √
AFE18-60A| Fossil Fuel (Dual Fuel) Kit| √| √| √| √| √
HASFK| High-Altitude Natural Gas Kit| N/A| TBD| TBD| HASFK-1| HASFK-2
HASFK| High-Altitude LP Gas Kit| N/A| TBD| TBD| HASFK-1| HASFK-2
0270F05404| Horizontal Drain Tubing Kit| √| √| √| √| √
LPLP03| Low LP Gas Pressure Switch| √| √| √| √| √
LPM-08| LP Conversion Kits| —| √| √| √| √
LPM-30| LP Conversion Kit| √| —| —| —| —
__
Model
| __
Description
| AM9C96 0804CNA| AM9C96 1004CNA| AM9C96 1005CNA| AM9C96
1205DNA
---|---|---|---|---|---
72950| Concentric Vent Kit (2″)| √| √| √| —
72951| Concentric Vent Kit (3″)| √| √| √| √
RF000142| Drain Kit-Horizontal Left Vertical Flue| √| √| √| √
EFR02| External Filter Rack with 16″x25″
Permanent Filter
| √| √| √| —
0170K00000S| Flush Mount Vent Kit- 3″ or 2″| √| √| √| √
0170K00001S| Flush Mount Vent Kit- 2″| √| √| √| —
AFE18-60A| Fossil Fuel (Dual Fuel) Kit| √| √| √| √
HASFK| High-Altitude Natural Gas Kit| HASFK-2| HASFK-2| HASFK-3| HASFK-3
HASFK| High-Altitude LP Gas Kit| HASFK-2| HASFK-2| HASFK-2| HASFK-2
0270F05404| Horizontal Drain Tubing Kit| √| √| √| √
LPLP03| Low LP Gas Pressure Switch| √| √| √| √
LPM-08| LP Conversion Kits| √| √| √| √
LPM-30| LP Conversion Kit| —| —| —| —
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>