Altronix AL624E Linear Power Supply/Charger

Overview

Altronix AL624E Linear Power Supply/Charger converts a low voltage AC input to a low voltage DC output. This general purpose power supply has a wide range of applications for access control, security and CCTV system accessories that require additional power.

Specifications

Agency Listing:

  • CE European Conformity.

Input:

  • Input 16VAC to 24VAC, 20VA to 40VA (Voltage Output/Transformer Selection Table)

Output:

  • Switch selectable 6VDC-12VDC-24VDC.
  • 1.2A continuous supply current at 6VDC-12VDC.
  • 750mA continuous supply current at 24VDC.
  • Filtered and electronically regulated output.

Battery Backup:

  • Built-in charger for sealed lead acid or gel type batteries.
  • Maximum charge current 300mA.
  • Automatic switchover to stand-by battery when

AC fails.

  • PTC battery protection.

Additional Features:

  • Thermal and short circuit protection with auto reset.
  • AC input and DC output LED indicators.
  • Extremely compact design.
  • Includes battery leads and enclosure.

Enclosure Dimensions (H x W x D):
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).

Voltage Output/Transformer Selection Table

Output

(continuous supply current)

| Voltage Selector (JMPR)| Transformer
---|---|---
6VDC @1.2A| Cut Jumper J2 Only| 12VAC / 20 VA (Altronix model TP1220)
12VDC @ 1.2A| Leave J1 & J2 Intact| 16.5VAC / 20 VA (Altronix model TP1620)
24VDC @ 750mA| Cut Jumper J1 Only| 24VAC / 40 VA (Altronix model TP2440)

Installation Instructions

Altronix-AL624E-Linear-Power-Supply-Charger-
FIG-1

  1. Mount AL624 into an enclosure (Fig. 1, pg. 2).

  2.  Mount AL624E in desired location.

  3.  The unit is factory set for 12VDC. For 6VDC output cut jumper J2, for 24VDC output cut Jumper J1.

  4.  Connect proper transformer to terminals marked [AC] (Voltage Output/Transformer Selection Table).
    Use 18 AWG or larger for all power connections (Battery, DC output).

  5. Measure output voltage before connecting devices. This helps avoid potential damage.

  6. Connect devices to be powered to the terminals marked [+ DC] and [DC – BAT] carefully observing polarity.

  7. Connect the battery to the terminals marked [BAT +] and [DC – NEG] (battery leads included).
    Note: When batteries are not used, a loss of AC will result in a loss of output voltage.

LED Diagnostics

Red (DC) Green (AC) Power Supply Status
ON ON Normal operating conditions
ON OFF Loss of AC. Stand-by battery is supplying power.
OFF ON No DC output. Short circuit or thermal overload condition.
OFF OFF No DC output. Loss of AC. Discharged or no battery present.

Terminal Identification

Terminal Legend Function/Description
AC/AC Low voltage AC input (Voltage Output/Transformer Selection

Table, pg.1).
+ DC –| 6VDC or 12VDC @ 1.2A continuous supply current.
– BAT +| Stand-by battery connections. Maximum charge rate 300mA.

Altronix is not responsible for any typographical errors

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIAL624E – Rev. 091211 F21U

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals