hansgrohe AXOR URQUIOLA Concealed Thermostat with Shut Off Valve Instruction Manual

October 30, 2023
hansgrohe

hansgrohe AXOR URQUIOLA Concealed Thermostat with Shut Off Valve

hansgrohe AXOR URQUIOLA Concealed Thermostat with Shut Off
Valve

Safety Notes

Gloves should be worn during installation to prevent crushing and cutting injuries.

The shower system may only be used for bathing, hygienic and body cleansing purposes.

Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.

The hot and cold supplies must be of equal pressures.

Installation Instructions

The fitting must be installed, flushed and tested after the valid norms!

Technical Data

Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 – 0,5MPa
Test pressure: 1,6MPa (1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Rate of flow by 0,3 MPa: approx. 26 l/min anti-pollution function

Symbol description

| Do not use silicone containing acetic acid!
---|---

Safety Function

| The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.
---|---

Safety Function
Safety Function

Adjustment

After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.

Adjustment

Maintenance

  • To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
  • The mixer is equipped with non return valves. The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). At this time, please also check the filter (A) situated on the MTC-thermoelement (94282000). After assembling the MTC-thermoelement, it is necessary to check the water temperature at the take off point as described under the headline “adjustment”. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the take off point.

Maintenance
Maintenance
Maintenance

Dimensions

  • Starck
    10700000
    Dimension

  • Starck X
    10706000
    Dimension

  • Montreux
    16800XXX
    Dimension

  • Carlton
    17700XXX
    Dimension

  • Carlton
    17705XXX
    Dimension

  • Massaud
    18745000
    Dimension

  • Citterio M
    34705000
    Dimension

  • Steel
    35700800
    Dimension

  • Uno
    38700000
    Dimension

  • Citterio
    39700000
    Dimension

  • Citterio
    39705000
    Dimension

  • Bouroullec
    19704000
    Dimension

Spare parts

  • XXX = Colors
  • 000 chrome plated
  • 090 chrome plated/gold plated
  • 800 stainless steel optic
  • 820 brushed nickel
  • 830 polished nickel

Spare parts
Spare parts
Spare parts
Spare parts

Operation

Operation

Cleaning

see enclosed brochure.

Test certificate

| PA.fX| DVGW| SVGW| ACS| WRAS| MCA| KIWA
---|---|---|---|---|---|---|---
10700000| 97 11/ ID| | X| X| X| X| X
10706000| 97 11/ ID| | | X| | X| X
16800XXX| 97 11/ ID| | | X| | X| X
17700XXX| 97 11/ ID| | X| X| X| X| X
17705XXX| 97 11/ ID| | X| X| X| X| X
18745000| 9711/ ID| | | X| | X| X
34705000| 97 11/ ID| | | X| | |
35700800| 97 11/ ID| | X| X| X| X| X
37700000| 97 11/ ID| | X| X| X| X| X
37705000| 97 11/ ID| | X| X| X| X| X
38700000| 97 11/ ID| | X| X| X| X| X
39700000| 97 11/ ID| | X| X| X| X| X
39705000| 97 11/ ID| | X| X| X| X| X
19704000| | | | | X| |

Test certificate

Fault Cause Remedy
Insufficient water
  • Supply pressure inadequate

|

  • Check water pressure (If a pump has been installed check to see if the pump is working).

  • Regulator filter dirty

|

  • Clean filters

  • Shower filter sea l dirty

|

  • Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed|

  • Backflow preventers dirty or leaking

|

  • Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with temperature set|

  • Thermostat has not been adjusted

|

  • Adjust thermostat

  • Hot water temperature too low

|

  • Increase hot water temperature to 42 °C to 65 °C

Temperature regulation not possible|

  • Temperature regulator dirty or calcified

|

  • Clean temperature regulator, exchange if necessary

  • For new installations: basic body incorrectly connected (should be: cold right, hot left) ,or installed with 180° rotation

|

  • Install function block turned through 180°

Safety stop button not operating|

  • Spring defective
  • Button calcified

|

  • Clean spring and/or button, exchange if necessary

Valve stiff|

  • Shut-off unit damaged

|

  • Exchange shut-off unit

Shower or spout dripping|

  • Dirt or sedimentation on valve seat, shut-off unit damaged

|

  • Clean or exchange shut-off unit

Assembly

Assembly
Assembly
Assembly
Assembly

Massaud/Bouroullec

Assembly
Assembly
Assembly

Other Products

  • Starck
    10700000

  • Starck X
    10706000

  • Montreux
    16800XXX

  • Carlton
    17700XXX

  • Carlton
    17705XXX

  • Massaud
    18745000

  • Citterio M
    34705000

  • Steel
    35700800

  • Uno
    38700000

  • Citterio
    39700000

  • Citterio
    39705000

  • Bouroullec
    19704000

hansgrohe Logo

Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440
E-Mail: [email protected] · Internet: www.hansgrohe.com

AXOR Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

hansgrohe User Manuals

Related Manuals