Hansgrohe 13125000 Ecostat E Wall Mounted Shower Thermostat Instruction Manual
- October 30, 2023
- hansgrohe
Table of Contents
13125000 Ecostat E Wall Mounted Shower Thermostat
Instruction Manual
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
Children as well as adults with physical, mental and/or sensorics impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
The hot and cold supplies must be of equal pressures.
Installation Instructions
The fitting must be installed, flushed and tested after the valid norms!
Thermostatic mixer in conjunction with combination boilers
- If fitting a hand shower remove the water limiter from the shower.
- If the continuous water heater causes any problems, or you have different water pressures you must install a water limiter to the cold supply, (ordered separately, article number 97510000).
- Thermostatic mixer Shower: When mounting the ECOSTOP limit stop washer (Art. No. 98916000) in connection with flow heaters, turn it axially through 180° before attaching it.
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 – 0,5MPa
Test pressure: 1,6MPa (1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C anti-pollution function
Symbol description
| Do not use silicone containing acetic acid!
---|---
| Safety Function (see page 62)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
| Adjustment (see page 63)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
| ECOSTOP (see page 64)
| Maintenance (see page 65)
• To guarantee the smooth running of the thermostat, it is necessary from time
to time to turn the thermostat from total hot to total cold.
• The mixer is equipped with non return valves. The non return valves must be
checked regularly according to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
| Operation (see page 66)
| Dimensions (see page 68)
| Flow diagram (see page 69)
① Shower
② Bath tub
---|---
| Spare parts (see page 70)
**| Test certificate (see page 72)
Fault| Cause| Remedy**
---|---|---
Insufficient water| – Supply pressure inadequate| – Check water pressure (If a
pump has been installed check to see if the pump is working).
– Filters are dirty (96922000)| – Clean filter in front of the mixer and on
the MTC-thermo cartridge (96922000)
– Shower filter seal dirty| – Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when
mixer is closed| – Backflow preventers dirty or leak- ing| – Clean backflow
preventers, ex-change if necessary
Spout temperature does not cop respond with temperature set| – Thermostat has
not been adjusted| – Adjust thermostat
– Hot water temperature too low| – Increase hot water temperature to 42 °C to
65 °C
Temperature regulation not possible| – thermo cartridge calcified| – Exchange
thermo cartridge
Shower or spout dripping| – Dirt or sedimentation on valve seat, shut-off unit
damaged| – Clean or exchange shut-off unit
Instantaneous heater didn’t work with thermostat| – Eco stop limit stop
– washer not turned
– axially through 180| – Turn the limit stop washer
– (98916000) axially through 180°
– Flow limiter in hand shower isn’t removed| – Remove flow limiter
– Filters are dirty| – Clean the filter / exchange filter
– Non return valve hasn’t moved back| – Exchange non return valves
Assembly
|
---|---
|
|
|
|
| PA-IX| DVGW| SVGW| ACS| WRAS| KIWA| ETA
---|---|---|---|---|---|---|---
13124000| | | | | | |
13125000| PA-IX 18988/IB| BT0641| X| X| X| X| X
13126000| | | | | | |
13144000| | | | | | |
13145000| PA-IX 18986/ICB| BT0641| X| X| X| X| X
13235000| PA-IX 18988/IB| BT0641| X| X| X| X| X
13236000| | | | | | |
13245000| PA-IX 18987/ICB| BT0641| X| X| X| X| X
Hansgrohe · Postfach 1145
D-77761 Schiltach
Telefon +49 (0) 78 36/51-1282
Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com
Internet: www.hansgrohe.com
02/201 1
9.04430.03
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>