hansgrohe 10715000 AXOR Starck Shower Mixers Instruction Manual

October 30, 2023
hansgrohe

hansgrohe 10715000 AXOR Starck Shower Mixers

hansgrohe-10715000-AXOR-Starck-Shower-Mixers-PRODUCT

Product Information

The user manual provides instructions in multiple languages for the installation and use of various shower systems. It includes technical data such as operating pressure, recommended hot water temperature, and flow rate. The manual also provides information on safety precautions, maintenance, and cleaning.

Product Usage Instructions

Safety Notes

  • Gloves should be worn during installation to prevent crushing and cutting injuries.
  • The shower system may only be used for bathing, hygienic and body cleansing purposes.
  • Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision.
  • Persons under the influence of alcohol or drugs are prohibited from using this shower system.
  • The hot and cold supplies must be of equal pressures.

Installation Instructions:

  • The fitting must be installed, flushed and tested after the valid norms!

Usage Instructions:

  • To fix dripping from the showerhead or spout, clean the filters. Refer to page 60 for installation instructions.
  • If the water pressure is not sufficient, clean the dirt strainer of the control unit or the seal gasket of the showerhead. Adjust the thermostat if necessary. Refer to page 63 forinstructions on adjusting the thermostat.
  • If the warm water temperature is too low, clean or replace the temperature control unit. Clean and lubricate the spring or pressure button, and replace the shut-off valve if necessary. Refer to page 64 for maintenance instructions.
  • Clean the shower system regularly. Refer to the brochure for cleaning instructions.

Models

hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(20\) Safety Notes

  • Gloves should be worn during installation to prevent crushing and cutting injuries.
  • The shower system may only be used for bathing, hygienic and body cleansing purposes.
  • Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.
  • The hot and cold supplies must be of equal pressures.

Installation Instructions

The fitting must be installed, flushed and tested after the valid norms!hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(1\) hansgrohe-10715000-AXOR-Starck-Shower-
Mixers-FIG- \(2\) hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(3\)

Technical Data

  • Operating pressure: max. 1 MPa

  • Recommended operating pressure: 0,1 – 0,5MPa

  • Test pressure: 1,6MPa
    (1 MPa = 10 bar = 147 PSI)

  • Hot water temperature: max. 80°C

  • Recommended hot water temp.: 65°C

  • Rate of flow by anti-pollution function 0,3 MPa: approx. 58 l/min

Symbol description

  • Do not use silicone containing acetic acid!

  • Safety Function (see page 62)
    The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(6\)hansgrohe-10715000-AXOR-Starck-Shower-
Mixers-FIG- \(7\)

  • Adjustment (see page 63)
    After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostathansgrohe-10715000-AXOR-
Starck-Shower-Mixers-FIG- \(8\)

Maintenance

hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(8\) hansgrohe-10715000-AXOR-Starck-Shower-
Mixers-FIG- \(10\)hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(11\)

  • To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
  • The mixer is equipped with non return valves. The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). At this time, please also check the filter (A) situated on the BTC-thermoelement (96633000). After assembling the BTC-thermoelement, it is necessary to check the water temperature at the take off point as described under the headline „adjustment“. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the take off point

Dimensions

hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(12\) hansgrohe-10715000-AXOR-Starck-
Shower-Mixers-FIG- \(13\) hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(14\)

Spare parts

hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(16\) hansgrohe-10715000-AXOR-Starck-
Shower-Mixers-FIG- \(17\) hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
\(18\)

  • XXX = Colors
  • 000 chrome plated
  • 090 chrome plated/gold plated
  • 800 stainless steel optic
  • 820 brushed nickel
  • 830 polished nickel

Operation

Test certificate

| PA-IX| DVGW| SVGW| ACS| WRAS| NF| KIWA
---|---|---|---|---|---|---|---
10715000| 18019/II| BQ0587| X| X| X| X| X
10717000| 18019/II| BQ0587| X| X| X| X| X
16815XXX| 18019/II| BQ0587| X| X| X| X| X
17712XXX| 18019/II| BQ0587| X| X| X| X| X
17716XXX| 18019/II| BQ0587| X| X| X| X| X
18741000| 18019/II| BQ0587| X| X| X| X| X
35715800| 18019/II| BQ0587| X| X| X| X| X
34716000| 18019/II| BQ0587| | | X| X|
37711000| 18019/II| BQ0587| X| X| X| X| X
37716000| 18019/II| BQ0587| X| X| X| X| X
38715000| 18019/II| BQ0587| X| X| X| X| X
39711000| 18019/II| BQ0587| X| X| X| X| X
39716000| 18019/II| BQ0587| X| X| X| X| X
19702000| | | | | X| |


TROUBLESHOOTING

hansgrohe-10715000-AXOR-Starck-Shower-Mixers-FIG-
21

Hansgrohe
Postfach 1145
D-77761 Schiltach
Telefon +49 (0) 78 36/51-1282
Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com
Internet: www.hansgrohe.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

hansgrohe User Manuals

Related Manuals