hansgrohe Starck 10715000 High Flow Thermostatic Mixer Instruction Manual
- October 30, 2023
- hansgrohe
Table of Contents
hansgrohe Starck 10715000 High Flow Thermostatic Mixer
OTHER MODEL
-
Starck
10715000
-
Starck X 10717000
-
Montreux 16815XXX
-
Carlton 17712XXX
-
Carlton 17716XXX
-
Massaud 18741000
-
Citterio M 34716000
-
Steel 35715800
-
Terrano 37711000
-
Terrano 37716000
-
Uno 38715000
-
Citterio 39711000
-
Citterio 39716000
-
Bouroullec 19702000
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
Children as well as adults with physical, mental and/ or sensoric impairments
must not use this shower
system without proper supervision. Persons under the influence of alcohol or
drugs are prohibited from using this shower system.
The hot and cold supplies must be of equal pressures
Installation Instructions
The fitting must be installed, flushed and tested after the valid norms!
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 – 0,5MPa
Test pressure: 1,6MPa (1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Rate of flow by 0,3 MPa: approx. 58 l/min anti-pollution function
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 62)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.
Adjustment
(see page 63)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
After the installation, the output temperature of the thermostat must be
checked.
A correction is necessary if the temperature measured at the output differs
from the temperature set on the thermostat.
Maintenance
(see page 64)
To guarantee the smooth running of the thermostat, it is necessary from time
to time to turn the thermostat from total hot to total cold.
The mixer is equipped with non return valves. The non return valves must be
checked regularly according to DIN EN 1717 in accordance with national or
regional regulations (at least once a year). At this time, please also check
the filter (A) situated on the BTC-thermoelement (96633000). After assembling
the BTC-thermoelement, it is necessary to check the water temperature at the
take off point as described under the headline „adjustment“. Before the
adjustment, please check, if the warm water supply is activated and the
maximum temperature of the warm water is available at the take off point.
Dimensions
**(see page 66)
**
Spare parts
(see page 68)
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
800 stainless steel optic
820 brushed nickel
830 polished nickel
Operation
**(see page 70)
**
Cleaning
see enclosed brochure.
Test certificate
(see page 67)
PA-IX | DVGW | SVGW | ACS | WRAS | NF | KIWA |
---|---|---|---|---|---|---|
10715000 | 18019/ 11 | BQ0587 | X | X | X | X |
10717000 | 18019/ 11 | BQ0587 | X | X | X | X |
16815XXX | 18019/ 11 | BQ0587 | X | X | X | X |
17712XXX | 18019/ 11 | BQ0587 | X | X | X | X |
17716XXX | 18019/ 11 | BQ0587 | X | X | X | X |
18741000 | 18019/ 11 | BQ0587 | X | X | X | X |
35715800 | 18019/ 11 | BQ0587 | X | X | X | X |
34716000 | 18019/ 11 | BQ0587 | X | X | ||
37711000 | 18019/ 11 | BQ0587 | X | X | X | X |
37716000 | 18019/ 11 | BQ0587 | X | X | X | X |
38715000 | 18019/ 11 | BQ0587 | X | X | X | X |
39711000 | 18019/ 11 | BQ0587 | X | X | X | X |
39716000 | 18019/ II | BQ0587 | X | X | X | X |
19702000 | X |
Assembly
Starck7a
Massaud **7b**
Fault | Cause | Remedy |
---|---|---|
Insufficient water |
- Supply pressure inadequate
|
-
Check water pressure (If a pump has been installed check to see if the pump is working).
-
Regulator filter dirty
|
-
Clean filters
-
Shower filter seal dirty
|
- Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed|
- Backflow preventers dirty or leaking
|
- Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with temperature set|
- Thermostat has not been adjusted
|
-
Spout temperature does not correspond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
|
- Adjust thermostat
Temperature regulation not possible|
- Temperature regulator dirty or calcified
|
-
Clean temperature regulator, exchange if necessary
-
For new installations: basic body incorrectly connected (should be: cold right, hot left) or installed with 180º rotation
|
- Install function block turned through 180º
Safety stop button not operating|
- Spring defective
- Button calcified
|
- Clean spring and/or button, exchange if necessary
Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282
· Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com ·
Internet: www.hansgrohe.com
References